메뉴 건너뛰기




Volumn , Issue , 2005, Pages 368-373

Fiber-optic sensor system for leakage current detection on insulator strings of overhead transmission lines

Author keywords

Fiber optic sensor; Flashover; Insulators; Leakage current

Indexed keywords

ELECTRIC CURRENT MEASUREMENT; ELECTRIC INSULATORS; ELECTRIC LINES; LEAKAGE CURRENTS; OPTICAL LINKS; OPTICAL SYSTEMS; WAVEFORM ANALYSIS;

EID: 33847209262     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IMOC.2005.1580046     Document Type: Conference Paper
Times cited : (3)

References (15)
  • 1
    • 0028529561 scopus 로고
    • Physics and Chemistry of Partial Discharge and Corona - Recent Advances and Future Challenges
    • October
    • R. J. Van Brunt, "Physics and Chemistry of Partial Discharge and Corona - Recent Advances and Future Challenges," IEEE Trans. on Dielectrics and Electrical Insulation, vol. 1, No. 5, pp. 761-784, October 1994.
    • (1994) IEEE Trans. on Dielectrics and Electrical Insulation , vol.1 , Issue.5 , pp. 761-784
    • Van Brunt, R.J.1
  • 2
  • 3
    • 0033076769 scopus 로고    scopus 로고
    • Relation Between Leakage Impedance and Equivalent Salt Deposit Density on an Insulator under a Saltwater Spray
    • February
    • H. Matsuo, T. Fujishima, T. Yamashita, "Relation Between Leakage Impedance and Equivalent Salt Deposit Density on an Insulator under a Saltwater Spray," IEEE Trans. on Dielectrics and Electrical Insulation, vol. 6, No. 1, pp. 117-121, February 1999.
    • (1999) IEEE Trans. on Dielectrics and Electrical Insulation , vol.6 , Issue.1 , pp. 117-121
    • Matsuo, H.1    Fujishima, T.2    Yamashita, T.3
  • 4
    • 0032187641 scopus 로고    scopus 로고
    • Development of a New Apparatus for Contamination Measurements of Overhead Transmission Line Insulators
    • October
    • K. Iwai, et al, "Development of a New Apparatus for Contamination Measurements of Overhead Transmission Line Insulators," IEEE Trans. on Power Delivery, vol. 13, No. 4, pp. 1412-1417, October 1998.
    • (1998) IEEE Trans. on Power Delivery , vol.13 , Issue.4 , pp. 1412-1417
    • Iwai, K.1
  • 5
    • 33750095160 scopus 로고    scopus 로고
    • Scintillation Modeling for insulator String under Polluted Conditions
    • August
    • D. C. Chaurasia, "Scintillation Modeling for insulator String under Polluted Conditions," IEEE Proc. of High Voltage Engineering Symposium, No. 467, August 1999.
    • (1999) IEEE Proc. of High Voltage Engineering Symposium , Issue.467
    • Chaurasia, D.C.1
  • 7
    • 12544250986 scopus 로고    scopus 로고
    • Frequency Characteristics of Leakage Current Waveforms of a String of Suspension Insulators
    • January
    • T. Suda, "Frequency Characteristics of Leakage Current Waveforms of a String of Suspension Insulators," IEEE Trans. On Power Delivery, vol. 20, No. 1, pp. 481-487, January 2005.
    • (2005) IEEE Trans. On Power Delivery , vol.20 , Issue.1 , pp. 481-487
    • Suda, T.1
  • 11
    • 0033311232 scopus 로고    scopus 로고
    • Formation and Characterization of Dry Bands in Clean Fog on Polluted Insulators
    • October
    • D. L. Williams, et al, "Formation and Characterization of Dry Bands in Clean Fog on Polluted Insulators," IEEE Trans. on Dielectrics and Electrical Insulation, vol. 6, No. 5, pp. 724-731, October 1999.
    • (1999) IEEE Trans. on Dielectrics and Electrical Insulation , vol.6 , Issue.5 , pp. 724-731
    • Williams, D.L.1
  • 12
    • 0023852453 scopus 로고
    • A new monitor for pollution on power line insulators - Part 2: Simulated field tests
    • January
    • M. Khalifa, et al, "A new monitor for pollution on power line insulators - Part 2: Simulated field tests," IEEE Proc. Generation, Transmission and Distribution, vol. 135, No. 1, pp. 24-30, January 1988.
    • (1988) IEEE Proc. Generation, Transmission and Distribution , vol.135 , Issue.1 , pp. 24-30
    • Khalifa, M.1
  • 13
    • 0025682246 scopus 로고
    • Development of Real-Time System for Simultaneous Observation of Visual Discharges and Leakage Current on Contaminated dc insulators
    • December
    • K. Isaka, et al, "Development of Real-Time System for Simultaneous Observation of Visual Discharges and Leakage Current on Contaminated dc insulators," IEEE Trans. on Dielectrics and Electrical Insulation, vol. 25, No. 6, pp. 1153-1160, December 1990.
    • (1990) IEEE Trans. on Dielectrics and Electrical Insulation , vol.25 , Issue.6 , pp. 1153-1160
    • Isaka, K.1
  • 14
    • 0141905723 scopus 로고    scopus 로고
    • Construction of Remote Monitoring System for Separative Measurements of Leakage Current of outdoors Insulators
    • June
    • S. Kurihara et al. "Construction of Remote Monitoring System for Separative Measurements of Leakage Current of outdoors Insulators," IEEE Proc. On Properties and Applications of Dielectric Mat., pp. 401-404, June 2003.
    • (2003) IEEE Proc. On Properties and Applications of Dielectric Mat , pp. 401-404
    • Kurihara, S.1
  • 15
    • 0035696051 scopus 로고    scopus 로고
    • Remote monitoring of Surface Current Over Insulators
    • November
    • M. Youssef, A. A. El-Alayly, "Remote monitoring of Surface Current Over Insulators," IEEE Transmission and Distribution Conf., vol. 01, pp. 113-116, November 2001.
    • (2001) IEEE Transmission and Distribution Conf , vol.1 , pp. 113-116
    • Youssef, M.1    El-Alayly, A.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.