메뉴 건너뛰기




Volumn 42, Issue 3, 2007, Pages 366-373

Improvement in the routine diagnostic assessment of the liver by high-resolution sonography: An analysis of 999 cases

Author keywords

Diagnostic test; High frequency transducer; Liver; Routine; Ultrasonography

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CHOLESTASIS; CONTROLLED STUDY; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; ECHOGRAPHY; FATTY LIVER; FEMALE; HEPATOMEGALY; HUMAN; LIVER CIRRHOSIS; LIVER DISEASE; LIVER PARENCHYMA; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; TRANSDUCER;

EID: 33847200039     PISSN: 00365521     EISSN: 15027708     Source Type: Journal    
DOI: 10.1080/00365520600979831     Document Type: Article
Times cited : (7)

References (30)
  • 2
    • 33645519040 scopus 로고    scopus 로고
    • Correlation between ultrasonographic and pathologic diagnosis of liver fibrosis due to chronic virus hepatitis
    • Shen L, Li JQ, Zeng MD, Lu LG, Fan ST, Bao H. Correlation between ultrasonographic and pathologic diagnosis of liver fibrosis due to chronic virus hepatitis. World J Gastroenterol 2006;28:1292-5.
    • (2006) World J Gastroenterol , vol.28 , pp. 1292-1295
    • Shen, L.1    Li, J.Q.2    Zeng, M.D.3    Lu, L.G.4    Fan, S.T.5    Bao, H.6
  • 3
    • 0037299277 scopus 로고    scopus 로고
    • Correlation between ultrasonographic and pathologic diagnoses of hepatitis B and C virus-related cirrhosis
    • Hung CH, Lu SN, Wang JH, Lee CM, Chen TM, Tung HD, et al. Correlation between ultrasonographic and pathologic diagnoses of hepatitis B and C virus-related cirrhosis. J Gastroenterol 2003;38:153-7.
    • (2003) J Gastroenterol , vol.38 , pp. 153-157
    • Hung, C.H.1    Lu, S.N.2    Wang, J.H.3    Lee, C.M.4    Chen, T.M.5    Tung, H.D.6
  • 4
    • 0035799899 scopus 로고    scopus 로고
    • Value of ultrasound diagnosis in evaluating a round liver lesion
    • Essig M. Value of ultrasound diagnosis in evaluating a round liver lesion. Schweiz Rundsch Med Prax 2001;90:773-8.
    • (2001) Schweiz Rundsch Med Prax , vol.90 , pp. 773-778
    • Essig, M.1
  • 5
    • 0027634879 scopus 로고
    • Exudative v/s transudative ascites: Differentiation based on fluid echogenicity on high resolution sonography
    • Malde HM, Gandhi RD. Exudative v/s transudative ascites: differentiation based on fluid echogenicity on high resolution sonography. J Postgrad Med 1993;39:132-3.
    • (1993) J Postgrad Med , vol.39 , pp. 132-133
    • Malde, H.M.1    Gandhi, R.D.2
  • 6
    • 0028918017 scopus 로고
    • Sonographic detection of peritoneal carcinomatosis: A prospective study of 37 cases
    • Rioux M, Michaud C. Sonographic detection of peritoneal carcinomatosis: a prospective study of 37 cases. Abdom Imaging 1995;20:47-51.
    • (1995) Abdom Imaging , vol.20 , pp. 47-51
    • Rioux, M.1    Michaud, C.2
  • 8
    • 0021012871 scopus 로고
    • Intraoperative high-resolution hepatosonography in the detection of occult metastases in colorectal carcinoma
    • Angelini L, Bezzi M, Tucci G, Bezzi M, Ciulli A, Bonifacino A, et al. Intraoperative high-resolution hepatosonography in the detection of occult metastases in colorectal carcinoma. Ital J Surg Sci 1983;13:203-8.
    • (1983) Ital J Surg Sci , vol.13 , pp. 203-208
    • Angelini, L.1    Bezzi, M.2    Tucci, G.3    Bezzi, M.4    Ciulli, A.5    Bonifacino, A.6
  • 9
    • 0022510435 scopus 로고
    • Intraoperative abdominal ultrasonography: Initial experience with a dedicated high-resolution operative transducer
    • Rifkin MD, Mack LA, Lennard ES, Shuman WP, Goldberg BB. Intraoperative abdominal ultrasonography: initial experience with a dedicated high-resolution operative transducer. J Ultrasound Med 1986;5:429-33.
    • (1986) J Ultrasound Med , vol.5 , pp. 429-433
    • Rifkin, M.D.1    Mack, L.A.2    Lennard, E.S.3    Shuman, W.P.4    Goldberg, B.B.5
  • 10
    • 0022457205 scopus 로고
    • Detection of unrecognized liver metastases from colorectal cancers by routine use of operative ultrasonography
    • Machi J, Isomoto H, Kurohiji T, Shirouzu K, Yamashita Y, Kakegawa T, et al. Detection of unrecognized liver metastases from colorectal cancers by routine use of operative ultrasonography. Dis Colon Rectum 1986;29:405-9.
    • (1986) Dis Colon Rectum , vol.29 , pp. 405-409
    • Machi, J.1    Isomoto, H.2    Kurohiji, T.3    Shirouzu, K.4    Yamashita, Y.5    Kakegawa, T.6
  • 12
    • 0141731314 scopus 로고    scopus 로고
    • Sonographic evaluation of the anterior liver surface in chronic liver diseases using a 7.5-MHz annular-array transducer: Correlation with laparascopic and histopathologic findings
    • Nagata N, Miyachi H, Nakano A, Nanri K, Kobayashi H, Matsuzaki S. Sonographic evaluation of the anterior liver surface in chronic liver diseases using a 7.5-MHz annular-array transducer: correlation with laparascopic and histopathologic findings. J Clin Ultrasound 2003;31:393-400.
    • (2003) J Clin Ultrasound , vol.31 , pp. 393-400
    • Nagata, N.1    Miyachi, H.2    Nakano, A.3    Nanri, K.4    Kobayashi, H.5    Matsuzaki, S.6
  • 13
    • 0344453816 scopus 로고    scopus 로고
    • Severe liver fibrosis or cirrhosis: Accuracy of US for detection: analysis of 300 cases
    • Colli A, Fraquelli M, Andreoletti M, Marino B, Zuccoli E, Conte D. Severe liver fibrosis or cirrhosis: accuracy of US for detection: analysis of 300 cases. Radiology 2003;227:89-94.
    • (2003) Radiology , vol.227 , pp. 89-94
    • Colli, A.1    Fraquelli, M.2    Andreoletti, M.3    Marino, B.4    Zuccoli, E.5    Conte, D.6
  • 14
    • 16344380610 scopus 로고    scopus 로고
    • Ultrasound evaluation of the fibrosis stage in chronic liver disease by simultaneous use of low and high frequency probes
    • Nishiura T, Watanabe H, Ito M, Matsuoka Y, Yano K, Daikoku M, et al. Ultrasound evaluation of the fibrosis stage in chronic liver disease by simultaneous use of low and high frequency probes. Br J Radiol 2005;78:189-97.
    • (2005) Br J Radiol , vol.78 , pp. 189-197
    • Nishiura, T.1    Watanabe, H.2    Ito, M.3    Matsuoka, Y.4    Yano, K.5    Daikoku, M.6
  • 17
    • 0032926285 scopus 로고    scopus 로고
    • The diagnosis of cirrhosis by high resolution ultrasound of the liver surface
    • Simonovsky V. The diagnosis of cirrhosis by high resolution ultrasound of the liver surface. Br J Radiol 1999;72:29-34.
    • (1999) Br J Radiol , vol.72 , pp. 29-34
    • Simonovsky, V.1
  • 21
    • 6344233067 scopus 로고    scopus 로고
    • Ultrasound of focal liver masses
    • Tchelepi H, Ralls PW. Ultrasound of focal liver masses. Ultrasound Q 2004;20:155-69.
    • (2004) Ultrasound Q , vol.20 , pp. 155-169
    • Tchelepi, H.1    Ralls, P.W.2
  • 22
    • 0025053639 scopus 로고
    • Prospective study of early detection of hepatocellular carcinoma in patients with cirrhosis
    • Oka A, Kurioka N, Kim K, Kanno T, Kuroki T, Mizoguchi Y, et al. Prospective study of early detection of hepatocellular carcinoma in patients with cirrhosis. Hepatology 1990;13:680-7.
    • (1990) Hepatology , vol.13 , pp. 680-687
    • Oka, A.1    Kurioka, N.2    Kim, K.3    Kanno, T.4    Kuroki, T.5    Mizoguchi, Y.6
  • 23
    • 0033925753 scopus 로고    scopus 로고
    • A meta-analysis of the literature for whole-body FDG PET detection of recurrent colorectal cancer
    • Huebner RH, Park KC, Shepherd JE, Schwimmer J, Czernin J, Phelps ME, et al. A meta-analysis of the literature for whole-body FDG PET detection of recurrent colorectal cancer. J Nucl Med 2000;41:1177-89.
    • (2000) J Nucl Med , vol.41 , pp. 1177-1189
    • Huebner, R.H.1    Park, K.C.2    Shepherd, J.E.3    Schwimmer, J.4    Czernin, J.5    Phelps, M.E.6
  • 24
    • 0036721291 scopus 로고    scopus 로고
    • Kinkel K, Lu Y, Both M, Warren RS, Thoeni RF. Detection of hepatic metastases from cancers of the gastrointestinal tract by using noninvasive imaging methods (US, CT, MR imaging, PET): a meta-analysis. Radiology 2002;224:748-56.
    • Kinkel K, Lu Y, Both M, Warren RS, Thoeni RF. Detection of hepatic metastases from cancers of the gastrointestinal tract by using noninvasive imaging methods (US, CT, MR imaging, PET): a meta-analysis. Radiology 2002;224:748-56.
  • 25
    • 0021319366 scopus 로고
    • Ultrasonography of small hepatic tumors using high-resolution linear-array real-time instruments
    • Sheu JC, Sung JL, Chen DS, Yu JY, Wang TH, Su CT, et al. Ultrasonography of small hepatic tumors using high-resolution linear-array real-time instruments. Radiology 1984;150:797-802.
    • (1984) Radiology , vol.150 , pp. 797-802
    • Sheu, J.C.1    Sung, J.L.2    Chen, D.S.3    Yu, J.Y.4    Wang, T.H.5    Su, C.T.6
  • 27
    • 1242317806 scopus 로고    scopus 로고
    • Improved characterisation of histologically proven liver tumours by contrast enhanced ultrasonography during the portal venous and specific late phase of SHU 508A
    • Dietrich CF, Ignee A, Trojan J, Fellbaum C, Schuessler G. Improved characterisation of histologically proven liver tumours by contrast enhanced ultrasonography during the portal venous and specific late phase of SHU 508A. Gut 2004;53:401-5.
    • (2004) Gut , vol.53 , pp. 401-405
    • Dietrich, C.F.1    Ignee, A.2    Trojan, J.3    Fellbaum, C.4    Schuessler, G.5
  • 28
    • 0036357755 scopus 로고    scopus 로고
    • Tissue harmonic imaging and contrast-specific imaging: Back to gray scale in ultrasound
    • Lencioni R, Cioni D, Bartolozzi C. Tissue harmonic imaging and contrast-specific imaging: back to gray scale in ultrasound. Eur Radiol 2002;12:151-65.
    • (2002) Eur Radiol , vol.12 , pp. 151-165
    • Lencioni, R.1    Cioni, D.2    Bartolozzi, C.3
  • 29
    • 0034060377 scopus 로고    scopus 로고
    • Evaluation of tissue harmonic imaging for the diagnosis of focal liver lesions
    • Tanaka S, Oshikawa O, Sasaki T, Ioka T, Tsukuma H. Evaluation of tissue harmonic imaging for the diagnosis of focal liver lesions. Ultrasound Med Biol 2000;26:183-7.
    • (2000) Ultrasound Med Biol , vol.26 , pp. 183-187
    • Tanaka, S.1    Oshikawa, O.2    Sasaki, T.3    Ioka, T.4    Tsukuma, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.