메뉴 건너뛰기




Volumn 35, Issue 2, 2007, Pages 201-210

Double-LED source for a portable photometer to determine iodine and formaldehyde in situ

Author keywords

Double LED source; Formaldehyde; Iodine; Portable photometer

Indexed keywords

FORMALDEHYDE; IODINE; LIGHT SOURCES; QUALITY CONTROL; SODIUM CHLORIDE; SPECTROPHOTOMETERS;

EID: 33847166567     PISSN: 10739149     EISSN: 15256030     Source Type: Journal    
DOI: 10.1080/10739140601126486     Document Type: Article
Times cited : (2)

References (24)
  • 2
    • 0033118224 scopus 로고    scopus 로고
    • The incredible shrinking mass spectrometers
    • Henry, C.M. The incredible shrinking mass spectrometers. Anal. Chem. 1999, 71, 264A-268A.
    • (1999) Anal. Chem , vol.71
    • Henry, C.M.1
  • 3
    • 0027607651 scopus 로고
    • A portable diffuse reflectance spectrophotometer for rapid and automatic measurement of tissue
    • Osawa, M.; Niwa, S. A portable diffuse reflectance spectrophotometer for rapid and automatic measurement of tissue. Meas. Sei. Technol. 1993, 4 (6), 668-676.
    • (1993) Meas. Sei. Technol , vol.4 , Issue.6 , pp. 668-676
    • Osawa, M.1    Niwa, S.2
  • 4
    • 0027794348 scopus 로고
    • Soil organic matter, CEC and moisture sensing with a portable NIR spectrophotometer
    • Sudduth, K.A.; Hummel, J.W. Soil organic matter, CEC and moisture sensing with a portable NIR spectrophotometer. Trans. ASAE 1993, 36 (6), 1571-1582.
    • (1993) Trans. ASAE , vol.36 , Issue.6 , pp. 1571-1582
    • Sudduth, K.A.1    Hummel, J.W.2
  • 5
    • 0030657832 scopus 로고    scopus 로고
    • Capillary electrophoresis detector using a light emitting diode and optical fibres
    • Butler, P.A.G.; Mills, B.; Hauser, P. Capillary electrophoresis detector using a light emitting diode and optical fibres. Analyst. 1997, 122 (9), 949-953.
    • (1997) Analyst , vol.122 , Issue.9 , pp. 949-953
    • Butler, P.A.G.1    Mills, B.2    Hauser, P.3
  • 6
    • 0001370933 scopus 로고
    • High performance optical absorbance detectors based on low noise switched integrators
    • Liu, H.; Dasgupta, P.K.; Zheng, H. High performance optical absorbance detectors based on low noise switched integrators. Talanta. 1993, 40 (9), 1331 -1338.
    • (1993) Talanta , vol.40 , Issue.9 , pp. 1331-1338
    • Liu, H.1    Dasgupta, P.K.2    Zheng, H.3
  • 7
    • 0030994924 scopus 로고    scopus 로고
    • An affordable high-performance optical absorbance detector for capillary systems
    • Boring, C.B.; Dasgupta, P.K. An affordable high-performance optical absorbance detector for capillary systems. Anal. Chim. Acta. 1997, 342, 123-132.
    • (1997) Anal. Chim. Acta , vol.342 , pp. 123-132
    • Boring, C.B.1    Dasgupta, P.K.2
  • 8
    • 0032830101 scopus 로고    scopus 로고
    • Optical fiber coupled light emitting diode based absorbance detector with a reflective flow cell
    • Jambunathan, S.; Dasgupta, P.K.; Wolcott, O.K.; Marshall, G.D.; Olson, D.C. Optical fiber coupled light emitting diode based absorbance detector with a reflective flow cell. Talanta 1999, 50 (3), 481-490.
    • (1999) Talanta , vol.50 , Issue.3 , pp. 481-490
    • Jambunathan, S.1    Dasgupta, P.K.2    Wolcott, O.K.3    Marshall, G.D.4    Olson, D.C.5
  • 9
    • 0032703586 scopus 로고    scopus 로고
    • An automated flowinjection titrator for spectrophotometric determinations of total acidity in wines, using a single standard solution and gradient calibration
    • Gaiao, E.N.; Honorato, R.S.; Santos, S.R.B.; Araujo, M.C.U. An automated flowinjection titrator for spectrophotometric determinations of total acidity in wines, using a single standard solution and gradient calibration. Analyst. 1999, 724(11), 1727-1730.
    • (1999) Analyst , vol.724 , Issue.11 , pp. 1727-1730
    • Gaiao, E.N.1    Honorato, R.S.2    Santos, S.R.B.3    Araujo, M.C.U.4
  • 10
    • 0033892278 scopus 로고    scopus 로고
    • Micro- and sub-nanosecond lifetime measurements using a UV light-emitting diode
    • Szmacinski, H.; Chang, Q. Micro- and sub-nanosecond lifetime measurements using a UV light-emitting diode. Appl. Spectres. 2000, 54 (1), 106-109.
    • (2000) Appl. Spectres , vol.54 , Issue.1 , pp. 106-109
    • Szmacinski, H.1    Chang, Q.2
  • 11
    • 0038459724 scopus 로고    scopus 로고
    • A low-cost device for automatic photometric titrations
    • Rocha, F.R.P.; Reis, B.F. A low-cost device for automatic photometric titrations. J. Chem. Educ. 2000, 77 (2), 258-261.
    • (2000) J. Chem. Educ , vol.77 , Issue.2 , pp. 258-261
    • Rocha, F.R.P.1    Reis, B.F.2
  • 12
    • 0031250386 scopus 로고    scopus 로고
    • Light-emitting diodes as sensors for colorimetric analyses
    • James, R.; Jay, B.; Harri, E.; Williams, R.R. Light-emitting diodes as sensors for colorimetric analyses. Appl. Spectros. 1997, 57 (10), 1521-1524.
    • (1997) Appl. Spectros , vol.57 , Issue.10 , pp. 1521-1524
    • James, R.1    Jay, B.2    Harri, E.3    Williams, R.R.4
  • 13
    • 33750328717 scopus 로고
    • Chinese National Environmental Protection Agency, Chinese Environmental Science & Technology Press: Beijing, China
    • Chinese National Environmental Protection Agency. Analytical Method for Air and Iste Gas Monitoring; Chinese Environmental Science & Technology Press: Beijing, China, 1990, 170-172.
    • (1990) Analytical Method for Air and Iste Gas Monitoring , pp. 170-172
  • 15
    • 9944244170 scopus 로고    scopus 로고
    • A new spectrum technique based on direct detection of light intensity absorbed. Sei. China B
    • 3
    • Zhao, Y.; Wang, D.; Guo, X.; Xu, J. A new spectrum technique based on direct detection of light intensity absorbed. Sei. China B 1998, 41 (3), 239-241.
    • (1998) , vol.41 , pp. 239-241
    • Zhao, Y.1    Wang, D.2    Guo, X.3    Xu, J.4
  • 16
    • 31244435448 scopus 로고    scopus 로고
    • Studies on the conformational interconversion of sulfonylurea molecules in solution by molecular dynamics simulation method
    • Chen, H.; Jin, Q.; Yang, L.; Luo, G. Studies on the conformational interconversion of sulfonylurea molecules in solution by molecular dynamics simulation method. Chem. J. Chinese Univ. 2001, 22 (6), 928-930.
    • (2001) Chem. J. Chinese Univ , vol.22 , Issue.6 , pp. 928-930
    • Chen, H.1    Jin, Q.2    Yang, L.3    Luo, G.4
  • 17
    • 0043221495 scopus 로고    scopus 로고
    • Simultaneous determination of metal ion concentrations in binary mixtures with a multi-LED photometer
    • Hauser, P.C.; Rupasinghe, T.W.T. Simultaneous determination of metal ion concentrations in binary mixtures with a multi-LED photometer. Fresen. J. Anal. Chem. 1997, 357, 1056-1060.
    • (1997) Fresen. J. Anal. Chem , vol.357 , pp. 1056-1060
    • Hauser, P.C.1    Rupasinghe, T.W.T.2
  • 18
    • 0000227301 scopus 로고    scopus 로고
    • Using a light-emitting diode as a high-speed, wavelength selective photodetector
    • Miyazaki, E.; Itami, S.; Araki, T. Using a light-emitting diode as a high-speed, wavelength selective photodetector. Rev. Sci. Instrum. 1998, 69(11), 3751-3754.
    • (1998) Rev. Sci. Instrum , vol.69 , Issue.11 , pp. 3751-3754
    • Miyazaki, E.1    Itami, S.2    Araki, T.3
  • 22
    • 0032526767 scopus 로고    scopus 로고
    • Ultraviolet and absorption light spectrometry
    • Howell, J.A.; Sutton, E. Ultraviolet and absorption light spectrometry. Anal. Chem. 1998, 70, 107R-118R.
    • (1998) Anal. Chem , vol.70
    • Howell, J.A.1    Sutton, E.2
  • 23
    • 33845555403 scopus 로고
    • Effect of temperature on the starch-iodine spectrophotometric calibration line
    • Hatch, G.L. Effect of temperature on the starch-iodine spectrophotometric calibration line. Anal. Chem. 1982, 54 (12), 2002-2005.
    • (1982) Anal. Chem , vol.54 , Issue.12 , pp. 2002-2005
    • Hatch, G.L.1
  • 24
    • 33847164639 scopus 로고
    • National Standards in People's Republic of China, GB5461-92, Edible Salt
    • National Standards in People's Republic of China, GB5461-92, Edible Salt, 1992.
    • (1992)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.