Volumn 2005, Issue , 2005, Pages 695-697

Testing, installation, commissioning and first operation of the ISIS RFQ pre-injector upgrade

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC CURRENTS; EQUIPMENT TESTING; NEUTRON BEAMS; NEUTRON SOURCES; PARTICLE BEAM INJECTION; SYNCHROTRON RADIATION; TARGETS;

EID: 33847165287     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PAC.2005.1590531     Document Type: Conference Paper
Times cited : (12)

References (10)
  • 1
    • 33847126356 scopus 로고    scopus 로고
    • H. Vormann et al., A New High Duty Factor RFQ Injector for ISIS, proc. EPAC 98, page 782.
    • H. Vormann et al., "A New High Duty Factor RFQ Injector for ISIS", proc. EPAC 98, page 782.
  • 2
    • 33847123114 scopus 로고    scopus 로고
    • The RFQ Test Stand Ion Source at RAL
    • EPAC
    • J.W.G. Thomason et al., "The RFQ Test Stand Ion Source at RAL", THPRI011, proc. EPAC2002.
    • (2002) THPRI011, proc
    • Thomason, J.W.G.1
  • 3
    • 33847140339 scopus 로고    scopus 로고
    • The Rutherford RFQ Test Stand
    • EPAC
    • D.J.S. Findlay et al., "The Rutherford RFQ Test Stand", THP4A03, proc. EPAC2000.
    • (2000) THP4A03, proc
    • Findlay, D.J.S.1
  • 4
    • 33847145165 scopus 로고    scopus 로고
    • First Results From The ISIS RFQ Test Stand
    • EPAC
    • A.P. Letchford et al., "First Results From The ISIS RFQ Test Stand", THP4A05, proc. EPAC2000.
    • (2000) THP4A05, proc
    • Letchford, A.P.1
  • 5
    • 33847132509 scopus 로고    scopus 로고
    • Measurements of RF Cavity Voltages By X-Ray Spectrum Measurements
    • J.P. Duke et al., "Measurements of RF Cavity Voltages By X-Ray Spectrum Measurements", MOC08, proc. LINAC2000.
    • MOC08, proc. LINAC2000
    • Duke, J.P.1
  • 6
    • 33847154137 scopus 로고    scopus 로고
    • Limits in the Design of Short Solenoids for Matching into RFQs
    • C.P. Bailey, "Limits in the Design of Short Solenoids for Matching into RFQs", THP10E, proc. EPAC98.
    • THP10E, proc. EPAC98
    • Bailey, C.P.1
  • 8
    • 33847162275 scopus 로고    scopus 로고
    • Measured Performance of the ISIS RFQ
    • EPAC
    • A.P. Letchford et al., "Measured Performance of the ISIS RFQ", THPLE045, proc. EPAC2002.
    • (2002) THPLE045, proc
    • Letchford, A.P.1
  • 9
    • 33847169214 scopus 로고    scopus 로고
    • J.P. Duke, A. Letchford, Design of an Electrostatic Energy Separator for the ISIS RFQ Test Stand, proc. PAC99, page 2208
    • J.P. Duke, A. Letchford, "Design of an Electrostatic Energy Separator for the ISIS RFQ Test Stand", proc. PAC99, page 2208
  • 10
    • 15744396851 scopus 로고    scopus 로고
    • Design and operation of a gas scattering energy spectrometer for the ISIS RFQ accelerator test stand
    • J.P. Duke, D.J.S. Findlay, A.P. Letchford, "Design and operation of a gas scattering energy spectrometer for the ISIS RFQ accelerator test stand", Nuclear Instruments and Methods A 538 (2005) 127.
    • (2005) Nuclear Instruments and Methods A , vol.538 , pp. 127
    • Duke, J.P.1    Findlay, D.J.S.2    Letchford, A.P.3