메뉴 건너뛰기




Volumn 1, Issue , 2005, Pages 178-181

Acoustic impedance measurement using PLSR based analysis of ultrasonic signals

Author keywords

Acoustic impedance; Concentration; Density; PLSR

Indexed keywords

GLYCEROL; LEAST SQUARES APPROXIMATIONS; PARAMETER ESTIMATION; REGRESSION ANALYSIS; ULTRASONICS;

EID: 33847128739     PISSN: 10510117     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ULTSYM.2005.1602825     Document Type: Conference Paper
Times cited : (2)

References (17)
  • 1
    • 0036679223 scopus 로고    scopus 로고
    • Application of Ultrasonic Sensors in the Process Industry
    • P. Hauptmann, N. Hoppe, and A. Püttmer, "Application of Ultrasonic Sensors in the Process Industry," Meas. Sci. Tech., vol. 13, no. 8, pp. R73-R83, 2002.
    • (2002) Meas. Sci. Tech , vol.13 , Issue.8
    • Hauptmann, P.1    Hoppe, N.2    Püttmer, A.3
  • 2
    • 33847094024 scopus 로고    scopus 로고
    • T. Abele et. al, Technologie-Roadmap: Prozess-Sensoren 2005-2015. NAMUR Geschäftsstelle, c/o Bayer Technology Services GmbH, Leverkusen, May 2005, p.32
    • T. Abele et. al., Technologie-Roadmap: Prozess-Sensoren 2005-2015. NAMUR Geschäftsstelle, c/o Bayer Technology Services GmbH, Leverkusen, May 2005, p.32.
  • 4
    • 33847166772 scopus 로고    scopus 로고
    • Ultraschall-Dichtesensor - Entwurf, Charakterisierung und Signalverarbeitung,
    • Ph.D. dissertation, Dept. Elect. Eng, Otto-von-Guericke-University Magdeburg, Magdeburg
    • N. Hoppe, "Ultraschall-Dichtesensor - Entwurf, Charakterisierung und Signalverarbeitung," Ph.D. dissertation, Dept. Elect. Eng., Otto-von-Guericke-University Magdeburg, Magdeburg, 2003, p. 19.
    • (2003) , pp. 19
    • Hoppe, N.1
  • 5
    • 0036679223 scopus 로고    scopus 로고
    • Application of Ultrasonic Sensors in the Process Industry
    • Y. Cohen, T. Xue, S. Lih, "Application of Ultrasonic Sensors in the Process Industry," Meas. Sci. Tech., vol. 13, no. 8, pp. R73-83, 2002.
    • (2002) Meas. Sci. Tech , vol.13 , Issue.8
    • Cohen, Y.1    Xue, T.2    Lih, S.3
  • 9
    • 0034354146 scopus 로고    scopus 로고
    • Partial least squares estimator for single-index models
    • P. Naik, C. Tsai, "Partial least squares estimator for single-index models," J. R. Statist. Soc. B, vol. 62, part 4, pp. R763-771, 2000.
    • (2000) J. R. Statist. Soc. B , vol.62 , Issue.PART 4
    • Naik, P.1    Tsai, C.2
  • 10
    • 33847124253 scopus 로고    scopus 로고
    • H. Wold, Systems Under Indirect Observation, Vols. I, II. Amsterdam: North Holland, 1982.
    • H. Wold, Systems Under Indirect Observation, Vols. I, II. Amsterdam: North Holland, 1982.
  • 12
    • 0016355478 scopus 로고
    • A new look at statistical model identification
    • Akaike, H.: A new look at statistical model identification. IEEE Trans. Autom. Contrl., Vol. 19, pp. 716-723, 1974.
    • (1974) IEEE Trans. Autom. Contrl , vol.19 , pp. 716-723
    • Akaike, H.1
  • 13
    • 0000068904 scopus 로고
    • A Test of Significance for Partial Least Squares Regression
    • Wakeling, I.N.; Morris, J.J.: A Test of Significance for Partial Least Squares Regression. J. Chemom., no. 7, pp. 291-304, 1993.
    • (1993) J. Chemom , Issue.7 , pp. 291-304
    • Wakeling, I.N.1    Morris, J.J.2
  • 14
    • 21144474350 scopus 로고
    • Linear Model Order Selection by Cross-Validation
    • June
    • Shao, J.: Linear Model Order Selection by Cross-Validation. J. Am. Stat. Assoc., Vol. 88, pp. 486-494, June 1993.
    • (1993) J. Am. Stat. Assoc , vol.88 , pp. 486-494
    • Shao, J.1
  • 15
    • 0003834924 scopus 로고    scopus 로고
    • Ultrasonic Density Sensor for Liquids,
    • Ph.D. dissertation, Dept. Elect. Eng, Otto-von-Guericke-University Magdeburg, Magdeburg
    • A. Püttmer, "Ultrasonic Density Sensor for Liquids," Ph.D. dissertation, Dept. Elect. Eng., Otto-von-Guericke-University Magdeburg, Magdeburg, 1998.
    • (1998)
    • Püttmer, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.