메뉴 건너뛰기




Volumn 1, Issue , 2005, Pages 385-388

New non-invasive method for intima-media thickness and intima-media compression measurements

Author keywords

Common carotid artery; Diameter change; Distension; IMC; IMT; Lumen diameter; Ultrasound

Indexed keywords

ALGORITHMS; CARDIOLOGY; MEDICAL IMAGING; OPTICAL RESOLVING POWER; ULTRASONIC IMAGING;

EID: 33847109679     PISSN: 10510117     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ULTSYM.2005.1602875     Document Type: Conference Paper
Times cited : (7)

References (14)
  • 1
    • 33847171718 scopus 로고    scopus 로고
    • W. W. Nichols and M. F. O'Rourke, McDonald's Blood Flow in Arteries, 4thed. London: Edward Arnold, 1998.
    • W. W. Nichols and M. F. O'Rourke, McDonald's Blood Flow in Arteries, 4thed. London: Edward Arnold, 1998.
  • 2
    • 0023002525 scopus 로고
    • Intimal plus media thickness of the arterial wall: A direct measurement with ultrasound imaging
    • P. Pignoli, E. Tremoli, A. Poli, P. Oreste, and R. Paoletti, "Intimal plus media thickness of the arterial wall: A direct measurement with ultrasound imaging," Circulation, vol. 74, pp. 1399-1406, 1986.
    • (1986) Circulation , vol.74 , pp. 1399-1406
    • Pignoli, P.1    Tremoli, E.2    Poli, A.3    Oreste, P.4    Paoletti, R.5
  • 3
    • 0032610263 scopus 로고    scopus 로고
    • Non-invasive measurement of mechanical properties of arteries in health and disease
    • A. P. Hoeks, P. J. Brands, J. M. Willigers, and R. S. Reneman, "Non-invasive measurement of mechanical properties of arteries in health and disease," Proc Inst Mech Eng, vol. 213, pp. 195-202, 1999.
    • (1999) Proc Inst Mech Eng , vol.213 , pp. 195-202
    • Hoeks, A.P.1    Brands, P.J.2    Willigers, J.M.3    Reneman, R.S.4
  • 4
    • 0026652153 scopus 로고
    • Use of monitoring software to improve the measurement of carotid wall thickness by B-mode imaging
    • P. J. Touboul, P. Prati, P.-Y. Scarabin, V. Adrai, E. Thibout, and P. Ducimetiere, "Use of monitoring software to improve the measurement of carotid wall thickness by B-mode imaging," Hypertension, vol. 10, pp. S37-S41, 1992.
    • (1992) Hypertension , vol.10
    • Touboul, P.J.1    Prati, P.2    Scarabin, P.-Y.3    Adrai, V.4    Thibout, E.5    Ducimetiere, P.6
  • 5
    • 0027190780 scopus 로고
    • Evidence for in vivo carotid and femoral wall thickness in human hypertension
    • J. Gariepy, M. Massonneau, J. Levenson, D. Heudes, and A. Simon, "Evidence for in vivo carotid and femoral wall thickness in human hypertension," Hypertension, vol. 22, pp. 111-118, 1993.
    • (1993) Hypertension , vol.22 , pp. 111-118
    • Gariepy, J.1    Massonneau, M.2    Levenson, J.3    Heudes, D.4    Simon, A.5
  • 6
    • 0027995413 scopus 로고
    • Evaluation of computerized edge tracking for quantifying intima-media thickness of the common carotid artery from B-mode ultrasound images
    • R. H. Selzer, H. N. Hodis, H. Kwong-Fu, W. J. Mack, P. L. Lee, C.-r. Liu, and C.-h. Liu, "Evaluation of computerized edge tracking for quantifying intima-media thickness of the common carotid artery from B-mode ultrasound images," Atherosclerosis, vol. 111, pp. 1-11, 1994.
    • (1994) Atherosclerosis , vol.111 , pp. 1-11
    • Selzer, R.H.1    Hodis, H.N.2    Kwong-Fu, H.3    Mack, W.J.4    Lee, P.L.5    Liu, C.-R.6    Liu, C.-H.7
  • 7
    • 0000815211 scopus 로고
    • A dynamic programming procedure for automated ultrasonic measurement of the carotid artery
    • T. Gustavsson, Q. Liang, I. Wendelhag, and J. Wikstrand, "A dynamic programming procedure for automated ultrasonic measurement of the carotid artery," IEEE Computers Cardiology Proc., pp. 297-300, 1994.
    • (1994) IEEE Computers Cardiology Proc , pp. 297-300
    • Gustavsson, T.1    Liang, Q.2    Wendelhag, I.3    Wikstrand, J.4
  • 8
    • 0033624995 scopus 로고    scopus 로고
    • A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images
    • Q. Liang, I. Wendelhag, J. Wikstrand, and T. Gustavsson, "A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images," IEEE Transactions on Medical Imaging, vol. 19, pp. 127-142, 2000.
    • (2000) IEEE Transactions on Medical Imaging , vol.19 , pp. 127-142
    • Liang, Q.1    Wendelhag, I.2    Wikstrand, J.3    Gustavsson, T.4
  • 12
    • 0034477937 scopus 로고    scopus 로고
    • Anisotropic edge-preserving smoothing in carotid B-mode ultrasound for improved segmentation and intima-media thickness (IMT) measurement
    • R. C. Chan, J. Kaufhold, L. C. Hemphill, R. S. Lees, and W. C. Karl, "Anisotropic edge-preserving smoothing in carotid B-mode ultrasound for improved segmentation and intima-media thickness (IMT) measurement," IEEE Computers in Cardiology 2000, pp. 37-40, 2000.
    • (2000) IEEE Computers in Cardiology 2000 , pp. 37-40
    • Chan, R.C.1    Kaufhold, J.2    Hemphill, L.C.3    Lees, R.S.4    Karl, W.C.5
  • 13
    • 0033907011 scopus 로고    scopus 로고
    • Real-time velocity for evaluation of change in thickness of arterial wall
    • H. Kanai, Y. Koiwa, "Real-time velocity for evaluation of change in thickness of arterial wall." Ultrasonics 38; 381-386, 2000
    • (2000) Ultrasonics , vol.38 , pp. 381-386
    • Kanai, H.1    Koiwa, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.