메뉴 건너뛰기




Volumn 2005, Issue , 2005, Pages 330-336

Semi-automatic tracking of the diaphragm contour in X-ray image sequences: Preliminary results

Author keywords

[No Author keywords available]

Indexed keywords

AUTOMATION; DIAPHRAGMS; DYNAMIC PROGRAMMING; IMAGE SEGMENTATION; INTERACTIVE COMPUTER GRAPHICS; MATHEMATICAL MODELS; X RAY OPTICS;

EID: 33847000534     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/DICTA.2005.1578146     Document Type: Conference Paper
Times cited : (4)

References (17)
  • 3
    • 2542430314 scopus 로고    scopus 로고
    • Fully automatic luminal contour segmentation in intracoronary ultrasound imaging - a statistical approach
    • May
    • E. Brusseau, C. L. De Korte, F. Mastik, J. Schaar, and A. F. W. Van Der Steen. Fully automatic luminal contour segmentation in intracoronary ultrasound imaging - a statistical approach. IEEE Transactions on Medical Imaging, 23(5):554-566, May 2004.
    • (2004) IEEE Transactions on Medical Imaging , vol.23 , Issue.5 , pp. 554-566
    • Brusseau, E.1    De Korte, C.L.2    Mastik, F.3    Schaar, J.4    Van Der Steen, A.F.W.5
  • 4
    • 0028235715 scopus 로고
    • New approach to automatic contour detection from image sequences: An application to ventriculographic images
    • June
    • M. Demi. New approach to automatic contour detection from image sequences: An application to ventriculographic images. Computers and Biomedical Research, 27(3): 157-177, June 1994.
    • (1994) Computers and Biomedical Research , vol.27 , Issue.3 , pp. 157-177
    • Demi, M.1
  • 5
    • 0024931636 scopus 로고
    • Automatic ventricular cavity boundary detection from sequential ultrasound images using simulated annealing
    • Dec
    • N. Friedland and D. Adam. Automatic ventricular cavity boundary detection from sequential ultrasound images using simulated annealing. IEEE Transactions on Medical Imaging, 8(4):344-353, Dec. 1989.
    • (1989) IEEE Transactions on Medical Imaging , vol.8 , Issue.4 , pp. 344-353
    • Friedland, N.1    Adam, D.2
  • 6
    • 33846990016 scopus 로고    scopus 로고
    • Honours Thesis, School of Electrical, Electronic and Computer Engineering, The University of Western Australia, Crawley, WA 6009, Australia, Nov
    • T. Fujita. Semi-Automatic Tracking of the Diaphragm Contour in Fluoroscopic Image Sequences. Honours Thesis, School of Electrical, Electronic and Computer Engineering, The University of Western Australia, Crawley, WA 6009, Australia, Nov. 2004.
    • (2004) Semi-Automatic Tracking of the Diaphragm Contour in Fluoroscopic Image Sequences
    • Fujita, T.1
  • 7
    • 2342579364 scopus 로고    scopus 로고
    • Unsupervised active contour model for biological image segmentation and analysis
    • New Delhi, India, Allied Publishers Pvt. Ltd. 15-17 Oct, Bangalore, India
    • K. Humnabadkar, S. Singh, D. Ghosh, and P. K. Bora. Unsupervised active contour model for biological image segmentation and analysis. In IEEE TENCON2003: Conference on Convergent Technologies for the Asia-Pacific Region, pages 538-542, New Delhi, India, 2003. Allied Publishers Pvt. Ltd. 15-17 Oct. 2003 , Bangalore, India.
    • (2003) IEEE TENCON2003: Conference on Convergent Technologies for the Asia-Pacific Region , pp. 538-542
    • Humnabadkar, K.1    Singh, S.2    Ghosh, D.3    Bora, P.K.4
  • 10
    • 24044433564 scopus 로고    scopus 로고
    • Segmentation of external force field for automatic initialization and splitting of snakes
    • C. Li, J. Liu, and M. D. Fox. Segmentation of external force field for automatic initialization and splitting of snakes. Pattern Recognition, 38(11):1947-1960, 2005.
    • (2005) Pattern Recognition , vol.38 , Issue.11 , pp. 1947-1960
    • Li, C.1    Liu, J.2    Fox, M.D.3
  • 11
    • 0030153642 scopus 로고    scopus 로고
    • Deformable models in medical image analysis: A survey
    • T. McInerney and D. Terzopoulos. Deformable models in medical image analysis: A survey. Medical Image Analysis, 1(2):91-108, 1996.
    • (1996) Medical Image Analysis , vol.1 , Issue.2 , pp. 91-108
    • McInerney, T.1    Terzopoulos, D.2
  • 14
    • 0037372565 scopus 로고    scopus 로고
    • Breath-by-breath measurement of the volume displaced by diaphragm motion
    • B. Singh, J. A. Panizza, and K. E. Finucane. Breath-by-breath measurement of the volume displaced by diaphragm motion. Journal of Applied Physiology, 94:1084-1091, 2003.
    • (2003) Journal of Applied Physiology , vol.94 , pp. 1084-1091
    • Singh, B.1    Panizza, J.A.2    Finucane, K.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.