메뉴 건너뛰기




Volumn 7 VOLS, Issue , 2005, Pages 5503-5506

Cancellation of respiratory artifact in impedance cardiography

Author keywords

Adaptive cancellation; Impedance cardiography; Respiratory artifact

Indexed keywords

BLOOD; CARDIOLOGY; FLOW OF FLUIDS; NONINVASIVE MEDICAL PROCEDURES; PARAMETER ESTIMATION; SIGNAL PROCESSING;

EID: 33846940251     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/iembs.2005.1615729     Document Type: Conference Paper
Times cited : (27)

References (24)
  • 2
    • 0024634657 scopus 로고
    • Fundamental of impedance cardiography
    • Mar
    • R. P. Patterson, "Fundamental of impedance cardiography," IEEE Eng. Med. Biol. Mag., vol. 8, pp. 35-38, Mar. 1989.
    • (1989) IEEE Eng. Med. Biol. Mag , vol.8 , pp. 35-38
    • Patterson, R.P.1
  • 4
    • 33846938427 scopus 로고    scopus 로고
    • J. Nyboer, Electrical Impedance Plethysmography. Springfield, Massachuates: Charles C. Thomas, 1970.
    • J. Nyboer, Electrical Impedance Plethysmography. Springfield, Massachuates: Charles C. Thomas, 1970.
  • 5
    • 0022812781 scopus 로고
    • Motion artifacts from spot and band electrodes during impedance cardiography
    • Nov
    • M. Qu, Y. Zang, J. G. Webster, and W. J. Tompkins, "Motion artifacts from spot and band electrodes during impedance cardiography," IEEE Trans. Biomed. Eng., vol. 33, pp. 1029-1036, Nov. 1986.
    • (1986) IEEE Trans. Biomed. Eng , vol.33 , pp. 1029-1036
    • Qu, M.1    Zang, Y.2    Webster, J.G.3    Tompkins, W.J.4
  • 6
  • 7
    • 0024627022 scopus 로고
    • Principle of the impedance cardiography technique
    • Mar
    • L. E. Baker, "Principle of the impedance cardiography technique," IEEE Eng. Med. Biol. Mag., vol. 8, pp. 11-15, Mar. 1989.
    • (1989) IEEE Eng. Med. Biol. Mag , vol.8 , pp. 11-15
    • Baker, L.E.1
  • 8
    • 12844275220 scopus 로고    scopus 로고
    • A new algorithm for improved detection of aortic valve opening by impedance cardiography
    • A. DeMarzo and R. M. lang, "A new algorithm for improved detection of aortic valve opening by impedance cardiography," Comp. in Cardiol, pp. 373-376, 1996.
    • (1996) Comp. in Cardiol , pp. 373-376
    • DeMarzo, A.1    lang, R.M.2
  • 14
    • 0028485943 scopus 로고
    • Cardiac and respiratory related electric impedance changes in the human thorax
    • Aug
    • B. H. Brown, D. C. Barber, A. H. Morica, and A. D. Leathard, "Cardiac and respiratory related electric impedance changes in the human thorax," IEEE Trans. Biomed. Eng., vol. 41(8), pp. 729-723, Aug. 1994.
    • (1994) IEEE Trans. Biomed. Eng , vol.41 , Issue.8 , pp. 729-723
    • Brown, B.H.1    Barber, D.C.2    Morica, A.H.3    Leathard, A.D.4
  • 16
    • 0029256729 scopus 로고
    • Signal-to-motion artifacts ratio versus frequency for impedance pneunmography
    • J. Rosell and J. G. Webster, "Signal-to-motion artifacts ratio versus frequency for impedance pneunmography," IEEE Trans. Biomed. Eng., vol. 42, pp. 321-323, 1995.
    • (1995) IEEE Trans. Biomed. Eng , vol.42 , pp. 321-323
    • Rosell, J.1    Webster, J.G.2
  • 17
    • 0024204850 scopus 로고
    • Design and implementation for beat-by-beat impedance cardiography
    • Dec
    • Y. Yamamoto, M. S. Tamura, Y. Mouth, M. Miyasita, and H. Hamamoto, "Design and implementation for beat-by-beat impedance cardiography," IEEE Trans. Biomed. Eng.,vol. 35(12), pp. 1086-1090, Dec. 1988.
    • (1988) IEEE Trans. Biomed. Eng , vol.35 , Issue.12 , pp. 1086-1090
    • Yamamoto, Y.1    Tamura, M.S.2    Mouth, Y.3    Miyasita, M.4    Hamamoto, H.5
  • 18
    • 0026221431 scopus 로고
    • Respiratory effects on cardiac related impedance indices measured under voluntry cardiorespiratory synchronisation (VCRS)
    • Sept
    • L. Wang, R. P. Paterson, and S. B. Raza, "Respiratory effects on cardiac related impedance indices measured under voluntry cardiorespiratory synchronisation (VCRS)," Med. Biol. Eng. Comput., pp. 505-510, Sept. 1991.
    • (1991) Med. Biol. Eng. Comput , pp. 505-510
    • Wang, L.1    Paterson, R.P.2    Raza, S.B.3
  • 19
    • 0026761081 scopus 로고
    • Filtering respiration and low-frequency movement artefacts from the cardiogenic electrical impedance signal
    • Sept
    • S. B. Raza, R. P. Patterson, and L. Wang, "Filtering respiration and low-frequency movement artefacts from the cardiogenic electrical impedance signal," Med. Biol. Eng. Comput., pp. 556-561, Sept. 1992
    • (1992) Med. Biol. Eng. Comput , pp. 556-561
    • Raza, S.B.1    Patterson, R.P.2    Wang, L.3
  • 20
    • 0029256652 scopus 로고
    • Filtering noncorrelated noise in impedance cardiography
    • Mar
    • A. K. Barrows, M. Yoshizawa, and Y. Yasuda, "Filtering noncorrelated noise in impedance cardiography," IEEE Trans. Biomed. Eng.,vol. 42(3), pp. 324-327, Mar. 1995.
    • (1995) IEEE Trans. Biomed. Eng , vol.42 , Issue.3 , pp. 324-327
    • Barrows, A.K.1    Yoshizawa, M.2    Yasuda, Y.3
  • 21
    • 0033693215 scopus 로고    scopus 로고
    • Quantile based noise estimation for spectral subtraction and Wiener filtering
    • V. Stahl, A. Fischer, and R. Bippus, "Quantile based noise estimation for spectral subtraction and Wiener filtering," in Proc. ICASSP '00, 2000, pp. 1875-1878.
    • (2000) Proc. ICASSP '00 , pp. 1875-1878
    • Stahl, V.1    Fischer, A.2    Bippus, R.3
  • 24
    • 33846940853 scopus 로고    scopus 로고
    • N. S. Manigandan, Development of hardware for impedance cardiography, M.Tech. thesis (unpublished), Biomed. Engg. Group, IIT Bombay, Mumbai, India, 2004.
    • N. S. Manigandan, "Development of hardware for impedance cardiography," M.Tech. thesis (unpublished), Biomed. Engg. Group, IIT Bombay, Mumbai, India, 2004.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.