메뉴 건너뛰기




Volumn 7 VOLS, Issue , 2005, Pages 944-947

A new muscle artifact removal technique to improve the interpretation of the ictal scalp electroencephalogram

Author keywords

Blind source separation; Canonical correlation analysis; Ictal EEG; Muscle artifact removal

Indexed keywords

BLIND SOURCE SEPARATION; CORRELATION METHODS; DATABASE SYSTEMS; ELECTROENCEPHALOGRAPHY; INDEPENDENT COMPONENT ANALYSIS; PATIENT MONITORING;

EID: 33846939308     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/iembs.2005.1616571     Document Type: Conference Paper
Times cited : (28)

References (12)
  • 2
    • 0041423684 scopus 로고    scopus 로고
    • EMG contamination of EEG: Spectral and topographical characteristics
    • I. Goncharova, D. McFarland, T. Vaughan, and J. Wolpaw, "EMG contamination of EEG: Spectral and topographical characteristics," Clinical Neurophysiology, vol. 114, pp. 1580-1593, 2003.
    • (2003) Clinical Neurophysiology , vol.114 , pp. 1580-1593
    • Goncharova, I.1    McFarland, D.2    Vaughan, T.3    Wolpaw, J.4
  • 3
    • 0036208030 scopus 로고    scopus 로고
    • Focal ictal beta, discharge on scalp EEG predicts excellent outcome of frontal lobe epilepsy surgery
    • G. Worell, E. So, J. Kazemi, T. O'Brien, R. Mosewich, G. Cascino, F. Meyer, and W. Marsh, "Focal ictal beta, discharge on scalp EEG predicts excellent outcome of frontal lobe epilepsy surgery," Epilepsia., vol. 43, no. 3.
    • Epilepsia , vol.43 , Issue.3
    • Worell, G.1    So, E.2    Kazemi, J.3    O'Brien, T.4    Mosewich, R.5    Cascino, G.6    Meyer, F.7    Marsh, W.8
  • 4
    • 0036126065 scopus 로고    scopus 로고
    • Independent component analysis of ictal EEG in medial temporal lobe epilepsy
    • H. Nam, T.-G. Yim, S. Han, J.-B. Oh, and S. Lee, "Independent component analysis of ictal EEG in medial temporal lobe epilepsy," Epilepsia, vol. 43, no. 2, pp. 160-164, 2002.
    • (2002) Epilepsia , vol.43 , Issue.2 , pp. 160-164
    • Nam, H.1    Yim, T.-G.2    Han, S.3    Oh, J.-B.4    Lee, S.5
  • 5
    • 4544350089 scopus 로고    scopus 로고
    • Independent component analysis removing artifacts in ictal recordings
    • E. Urrestarazu, J. Iriarte, M. Alegre, M. Valencia, C. Viteri, and J. Artieda, "Independent component analysis removing artifacts in ictal recordings," Epilepsia, vol. 45, no. 9, pp. 1071-1078, 2004.
    • (2004) Epilepsia , vol.45 , Issue.9 , pp. 1071-1078
    • Urrestarazu, E.1    Iriarte, J.2    Alegre, M.3    Valencia, M.4    Viteri, C.5    Artieda, J.6
  • 8
    • 0004236492 scopus 로고    scopus 로고
    • Baltimore: John Hopkins University Press, third ed
    • G. Golub and C. F. Van Loan, Matrix computations. Baltimore: John Hopkins University Press, third ed., 1996.
    • (1996) Matrix computations
    • Golub, G.1    Van Loan, C.F.2
  • 9
    • 33846911580 scopus 로고    scopus 로고
    • Muscle artifact removal from encephalograms
    • Patent Number GB0500180.5, filed 07 Jan. 2005
    • W. De Clercq, A. Vergult, W. Van Paesschen, and S. Van Huffel, "Muscle artifact removal from encephalograms." Patent Number GB0500180.5, filed 07 Jan. 2005.
    • De Clercq, W.1    Vergult, A.2    Van Paesschen, W.3    Van Huffel, S.4
  • 12
    • 0032612381 scopus 로고    scopus 로고
    • Higher-order contrast for independent component analysis
    • J.-F. Cardoso, "Higher-order contrast for independent component analysis," Neural Comput, vol. 11, pp. 157-192, 1999.
    • (1999) Neural Comput , vol.11 , pp. 157-192
    • Cardoso, J.-F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.