메뉴 건너뛰기




Volumn 7 VOLS, Issue , 2005, Pages 2272-2275

Experimental research on balloon-expandable endovascular stent expansion

Author keywords

In vitro stent expansion; LabVIEW; Machine vision; Medical endovascular stent

Indexed keywords

BIOMEDICAL EQUIPMENT; COMPUTER SIMULATION; COMPUTER VISION; ENDOSCOPY; FINITE ELEMENT METHOD;

EID: 33846937138     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (10)
  • 1
    • 10044238835 scopus 로고    scopus 로고
    • Finite-element simulation of slotted tube (stent) with the presence of plague and artery by balloon expansion
    • S. N. David Chua, B. J. Mac Donald, M. S. J. Hashmi, "Finite-element simulation of slotted tube (stent) with the presence of plague and artery by balloon expansion," Materials Processing Technology, vol. 155-156, pp. 1772-1779, 2004.
    • (2004) Materials Processing Technology , vol.155-156 , pp. 1772-1779
    • David Chua, S.N.1    Mac Donald, B.J.2    Hashmi, M.S.J.3
  • 3
    • 0036000226 scopus 로고    scopus 로고
    • Mechanical behavior of coronary stents investigated through the finite element method
    • Francesco Migliavacca, Lorenza Petrini, Maurizio Colombo, "Mechanical behavior of coronary stents investigated through the finite element method," Journal of Biomechanics, vol. 35, no. 6, pp. 803-811, 2002.
    • (2002) Journal of Biomechanics , vol.35 , Issue.6 , pp. 803-811
    • Migliavacca, F.1    Petrini, L.2    Colombo, M.3
  • 4
    • 1442299848 scopus 로고    scopus 로고
    • Numerical investigation of the intravascular coronary stent flexibility
    • Lorenza Petrini, Francesco Migliavacca, Ferdinando Auricchio, Gabriele Dubini, "Numerical investigation of the intravascular coronary stent flexibility," Journal of Biomechanics, vol. 37, no. 4, pp. 495-501,2004.
    • (2004) Journal of Biomechanics , vol.37 , Issue.4 , pp. 495-501
    • Petrini, L.1    Migliavacca, F.2    Auricchio, F.3    Dubini, G.4
  • 6
    • 0033157322 scopus 로고    scopus 로고
    • Effects of a positron-emitting VANADIUM-48 nitinol stent on experimental restenosis in porcine coronary arteries: An injury-response study
    • Neal Eigler, James Whiting, Alex Li, Aaron Frimerman, Raj Makkar, Jorg Hausleiter, "Effects of a positron-emitting VANADIUM-48 nitinol stent on experimental restenosis in porcine coronary arteries: An injury-response study," Cardiovascular Radiation Medicine, vol. 1, no.3, pp.239-251, 1999.
    • (1999) Cardiovascular Radiation Medicine , vol.1 , Issue.3 , pp. 239-251
    • Eigler, N.1    Whiting, J.2    Li, A.3    Frimerman, A.4    Makkar, R.5    Hausleiter, J.6
  • 8
    • 0038293022 scopus 로고    scopus 로고
    • Measurement of the symmetry of in vitro stent expansion: A stereo-photogrammetric approach
    • April
    • A. J. Narracott, D. R. Hose, P. V. Lawford, J.Gunn, "Measurement of the symmetry of in vitro stent expansion: a stereo-photogrammetric approach," Journal of Medical Engineering & Technology, vol. 27, no. 2, pp. 59-70, April.2003.
    • (2003) Journal of Medical Engineering & Technology , vol.27 , Issue.2 , pp. 59-70
    • Narracott, A.J.1    Hose, D.R.2    Lawford, P.V.3    Gunn, J.4
  • 9
    • 0034485714 scopus 로고    scopus 로고
    • A numerical and experimental study of periodic flow in a model of a corrugated vessel with application to stented arteries
    • S. Natarajan, M. R. Mokhtarzadeh-Dehghan, "A numerical and experimental study of periodic flow in a model of a corrugated vessel with application to stented arteries," Medical Engineering & Physics, vol. 22, pp. 555-566, 2000.
    • (2000) Medical Engineering & Physics , vol.22 , pp. 555-566
    • Natarajan, S.1    Mokhtarzadeh-Dehghan, M.R.2