-
1
-
-
1842429552
-
Active device tracking and high-resolution intravascular MRI using a novel catheter-based, opposed-solenoid phased array coil
-
C.M. Hillenbraud, D.R. Elgort, E.Y. Wong, A. Reykowski, F.K. Wacker, J.S. Lewin, J.L. Duerk, "Active device tracking and high-resolution intravascular MRI using a novel catheter-based, opposed-solenoid phased array coil". Magnetic Resonance Imaging in Medecine. 51: 4. pp. 668-675, 2004.
-
(2004)
Magnetic Resonance Imaging in Medecine
, vol.51
, Issue.4
, pp. 668-675
-
-
Hillenbraud, C.M.1
Elgort, D.R.2
Wong, E.Y.3
Reykowski, A.4
Wacker, F.K.5
Lewin, J.S.6
Duerk, J.L.7
-
2
-
-
0030854650
-
Catheter visualization using locally induced actively controlled field inhomogeneities
-
A. Glowinski, G. Adam, A. Bucker, J. Neuerburg, J.J. Van Vaals, R.W. Gunther, "Catheter visualization using locally induced actively controlled field inhomogeneities". Magnetic Resonance in Medicine, v 38, n 2, pp. 253-258, 1997.
-
(1997)
Magnetic Resonance in Medicine
, vol.38
, Issue.2
, pp. 253-258
-
-
Glowinski, A.1
Adam, G.2
Bucker, A.3
Neuerburg, J.4
Van Vaals, J.J.5
Gunther, R.W.6
-
3
-
-
0032173362
-
Image guidance of endovascular interventions on a clinical MR scanner
-
Oct
-
R. Van Der Weide, K.J. Zuiderveld, C.J.G Bakker, T. Hoogenboom, J.J. Van Vaals, A. Max. "Image guidance of endovascular interventions on a clinical MR scanner". IEEE Transactions on Medical Imaging. v17, n 1, Oct, 1998, p 779-785
-
(1998)
IEEE Transactions on Medical Imaging
, vol.17
, Issue.1
, pp. 779-785
-
-
Van Der Weide, R.1
Zuiderveld, K.J.2
Bakker, C.J.G.3
Hoogenboom, T.4
Van Vaals, J.J.5
Max, A.6
-
4
-
-
1542300654
-
-
J.-B. Mathieu, S. Martel, L. Yahia, G. Soulez, G. Beaudoin, MRI Systems as a mean of propulsion for a microdevice in blood vessels. Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439). Piscataway, NJ, USA: IEEE. 4, pp. 3419-3422, 2003.
-
J.-B. Mathieu, S. Martel, L. Yahia, G. Soulez, G. Beaudoin, "MRI Systems as a mean of propulsion for a microdevice in blood vessels". Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439). Piscataway, NJ, USA: IEEE. 4, pp. 3419-3422, 2003.
-
-
-
-
5
-
-
0141540607
-
Preliminary studies for using magnetic resonance imaging systems as a mean of propulsion for microrobots in blood vessels and evaluation of ferromagnetic artefacts
-
Montreal, Canada, pp
-
J-B. Mathieu, S. Martel, L. Yahia, G. Soulez, and G. Beaudoin, "Preliminary studies for using magnetic resonance imaging systems as a mean of propulsion for microrobots in blood vessels and evaluation of ferromagnetic artefacts," Canadian Congress on Electric and Computer Engineering, Montreal, Canada, pp 835-838, 2003.
-
(2003)
Canadian Congress on Electric and Computer Engineering
, pp. 835-838
-
-
Mathieu, J.-B.1
Martel, S.2
Yahia, L.3
Soulez, G.4
Beaudoin, G.5
-
6
-
-
33845332852
-
Method of propulsion of a ferromagnetic core in the cardiovascular system through magnetic gradients generated by an MRI system
-
in review
-
J-B. Mathieu, G. Beaudoin, and S. Martel, "Method of propulsion of a ferromagnetic core in the cardiovascular system through magnetic gradients generated by an MRI system," IEEE Trans. on Biomedical Eng., 2005 (in review)
-
(2005)
IEEE Trans. on Biomedical Eng
-
-
Mathieu, J.-B.1
Beaudoin, G.2
Martel, S.3
-
7
-
-
0034087960
-
Design and fabrication of a three-axis multilayer gradient coil for magnetic resonance microscopy of mice
-
June
-
B. Chronik, A. Alejski, B.K. Rutt. 2000. «Design and fabrication of a three-axis multilayer gradient coil for magnetic resonance microscopy of mice». Magnetic Resonance Materials in Physics, Biology and Medicine. v10, n 2, June 2000, pp. 131-146.
-
(2000)
Magnetic Resonance Materials in Physics, Biology and Medicine
, vol.10
, Issue.2
, pp. 131-146
-
-
Chronik, B.1
Alejski, A.2
Rutt, B.K.3
|