Can transventricular intracardiac impedance measurement discriminate haemodynamically unstable ventricular arrhythmias in human?

Author keywords

Haemodynamic stability; Transventricular intracardiac impedance; Ventricular tachycardia

Indexed keywords

ADULT; AGED; ARTERIAL PRESSURE; ARTICLE; CLINICAL ARTICLE; CORRELATION ANALYSIS; DISEASE CLASSIFICATION; ELECTROCARDIOGRAPHY; ELECTROGRAPHY; FEMALE; FEMORAL ARTERY; HEART CATHETER; HEART ELECTROPHYSIOLOGY; HEART HEMODYNAMICS; HEART VENTRICLE TACHYCARDIA; HEMODYNAMIC MONITORING; HUMAN; IMPEDANCE CARDIOGRAPHY; MALE; PRIORITY JOURNAL;

EID: 33846928758     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eul150     Document Type: Article
Times cited : (8)

References (10)
  • 2
    • 0022559393 scopus 로고
    • Measurement of ventricular volume by intracardiac impedance - Theoretical and empirical approaches
    • Sato RW, Wallner TG, Pedersen BD. Measurement of ventricular volume by intracardiac impedance - theoretical and empirical approaches. IEEE-Trans Biomed Eng 1986;33:189-95.
    • (1986) IEEE-Trans Biomed Eng , vol.33 , pp. 189-195
    • Sato, R.W.1    Wallner, T.G.2    Pedersen, B.D.3
  • 3
    • 0033782999 scopus 로고    scopus 로고
    • Closed-loop stimulation using intracardiac impedance as a sensor principle: Correlation of right ventricutair dP/dtmax and intracardiac impedance during dobutamine stress test
    • Osswald S, Cron T, Gradel C, Hilti P, Lippert M, Strobel J et al. Closed-loop stimulation using intracardiac impedance as a sensor principle: Correlation of right ventricutair dP/dtmax and intracardiac impedance during dobutamine stress test. Pacing Clin Electrophysiol 2000;23:1502-8.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 1502-1508
    • Osswald, S.1    Cron, T.2    Gradel, C.3    Hilti, P.4    Lippert, M.5    Strobel, J.6
  • 4
    • 0036097960 scopus 로고    scopus 로고
    • Continuous ambulatory right heart pressure measurements with an implantable haemodynamic monitor: A multicenter 12 month follow-up study of patients with chronic heart failure
    • Magalski A, Adamson P, Gadler F, Boehm M, Steinhaus D, Reynolds D et al. Continuous ambulatory right heart pressure measurements with an implantable haemodynamic monitor: A multicenter 12 month follow-up study of patients with chronic heart failure. J Card Fail 2002;8:63-70.
    • (2002) J Card Fail , vol.8 , pp. 63-70
    • Magalski, A.1    Adamson, P.2    Gadler, F.3    Boehm, M.4    Steinhaus, D.5    Reynolds, D.6
  • 5
    • 0024845707 scopus 로고
    • Continuous right ventricular volume assessment by catheter measurement of impedance for antitachycardia system control
    • Khoury D, McAllister H, Wilkoff B, Simmons T, Rudy Y, McCowan R et al. Continuous right ventricular volume assessment by catheter measurement of impedance for antitachycardia system control. Pacing Clin Electrophysiol 1989;12:1918-26.
    • (1989) Pacing Clin Electrophysiol , vol.12 , pp. 1918-1926
    • Khoury, D.1    McAllister, H.2    Wilkoff, B.3    Simmons, T.4    Rudy, Y.5    McCowan, R.6
  • 6
    • 33745632992 scopus 로고
    • Impedance, conductance, resistance: Definitions and measurement principles
    • In: Winter UJ, Klocke RK, Kubicek WG, Niederlag W, eds. Stuttgart: George Thieme
    • Irnich W. Impedance, conductance, resistance: Definitions and measurement principles. In: Winter UJ, Klocke RK, Kubicek WG, Niederlag W, eds. Thoracic impedance measurements in Clinical Cardiology. Stuttgart: George Thieme; 1994. p4-10.
    • (1994) Thoracic Impedance Measurements in Clinical Cardiology , pp. 4-10
    • Irnich, W.1
  • 7
    • 33846910457 scopus 로고    scopus 로고
    • Can the real time measurement of intracardiac impedance discriminate haemodynamically stable from unstable arrhythmias?
    • Thesis, University of Newcastle, Newcastle upon Tyne, UK
    • Arthur W. Can the real time measurement of intracardiac impedance discriminate haemodynamically stable from unstable arrhythmias? 2003: Thesis, University of Newcastle, Newcastle upon Tyne, UK.
    • (2003)
    • Arthur, W.1
  • 8
    • 33750314112 scopus 로고    scopus 로고
    • The use of unipolar intracardiac impedance for discrimination of haemodynamically stable and unstable arrhythmias in man
    • Kaye G, Arthur W, Edgar D, Lippert M, Czygan G. The use of unipolar intracardiac impedance for discrimination of haemodynamically stable and unstable arrhythmias in man. Europace 2006;8:988-93.
    • (2006) Europace , vol.8 , pp. 988-993
    • Kaye, G.1    Arthur, W.2    Edgar, D.3    Lippert, M.4    Czygan, G.5
  • 9
    • 0029928190 scopus 로고    scopus 로고
    • Analysis of right ventricular function during bypass of the left side of the heart by afterload alterations in both normal and failing hearts
    • Park CH, Nishimura K, Katano M, Matsuda K, Okamoto Y, Ban T. Analysis of right ventricular function during bypass of the left side of the heart by afterload alterations in both normal and failing hearts. J Thorac Cardiovasc Surg 1996; 111: 1092-1102.
    • (1996) J Thorac Cardiovasc Surg , vol.111 , pp. 1092-1102
    • Park, C.H.1    Nishimura, K.2    Katano, M.3    Matsuda, K.4    Okamoto, Y.5    Ban, T.6
  • 10
    • 33745593723 scopus 로고    scopus 로고
    • Determination of left ventricular volume changes by intracardiac conductance using a biventricutar electrode configuration
    • Zima E, Lippert M, Czygan G, Merkely B. Determination of left ventricular volume changes by intracardiac conductance using a biventricutar electrode configuration. Europace 2006;8:537-44.
    • (2006) Europace , vol.8 , pp. 537-544
    • Zima, E.1    Lippert, M.2    Czygan, G.3    Merkely, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.