메뉴 건너뛰기




Volumn 17, Issue 1, 2007, Pages 55-59

Donors whose blood reacts falsely positive in transfusion microbiology screening assays need not be lost to transfusion

Author keywords

False reactivity; Re admission; Resources; Transfusion microbiology

Indexed keywords

ARTICLE; BLOOD ANALYSIS; BLOOD DONOR; BLOOD TRANSFUSION; DONOR SELECTION; ENZYME LINKED IMMUNOSORBENT ASSAY; HEMATOLOGICAL PROCEDURES; HEPATITIS C; HEPATITIS C VIRUS; HUMAN; LABORATORY DIAGNOSIS; MICROBIOLOGY; PRACTICE GUIDELINE; SCREENING TEST; VIRUS DETECTION;

EID: 33846920583     PISSN: 09587578     EISSN: 13653148     Source Type: Journal    
DOI: 10.1111/j.1365-3148.2006.00700.x     Document Type: Article
Times cited : (13)

References (10)
  • 1
    • 0029885304 scopus 로고    scopus 로고
    • Safety and efficacy of hepatitis C virus antibody screening of blood donors with two sequential screening assays
    • Allain, J.P., Kitchen, A., Aloysius, S., Reeves, I., Petrik, J., Barbara, J.A.J. & Williamson, L.M. (1996) Safety and efficacy of hepatitis C virus antibody screening of blood donors with two sequential screening assays. Transfusion 36, 401-405.
    • (1996) Transfusion , vol.36 , pp. 401-405
    • Allain, J.P.1    Kitchen, A.2    Aloysius, S.3    Reeves, I.4    Petrik, J.5    Barbara, J.A.J.6    Williamson, L.M.7
  • 2
    • 33947626190 scopus 로고    scopus 로고
    • The National Blood Service (England) approach to evaluation of kits for detecting infectious agents
    • in press, in press
    • Barbara J. et al. (in press) The National Blood Service (England) approach to evaluation of kits for detecting infectious agents. Transfusion Medicine Reviews, in press.
    • Transfusion Medicine Reviews
    • Barbara, J.1
  • 3
    • 33846936327 scopus 로고    scopus 로고
    • Department of Health. Better blood transfusion: appropriate use of blood. Circular HSC 2002/009, 4 July 2002, Department of Health, UK.
    • Department of Health. Better blood transfusion: appropriate use of blood. Circular HSC 2002/009, 4 July 2002, Department of Health, UK.
  • 4
    • 0031068592 scopus 로고    scopus 로고
    • To they (reactive) donors be true!
    • Busch, M.P. (1997) To they (reactive) donors be true! Transfusion 37, 117-119.
    • (1997) Transfusion , vol.37 , pp. 117-119
    • Busch, M.P.1
  • 5
    • 6744226380 scopus 로고    scopus 로고
    • Noise' in microbiological screening assays
    • Dow, B. (2000) 'Noise' in microbiological screening assays. Transfusion Medicine 10, 97-106.
    • (2000) Transfusion Medicine , vol.10 , pp. 97-106
    • Dow, B.1
  • 7
    • 0028333744 scopus 로고
    • Evaluation of clinical and laboratory aspects of antibody tests for detection of hepatitis C virus infection in blood donors and recipients from a low-risk population
    • MacDonald, K.L., Mills, W.A., Wood, R.C. et al. (1994) Evaluation of clinical and laboratory aspects of antibody tests for detection of hepatitis C virus infection in blood donors and recipients from a low-risk population. Transfusion 34, 202-208.
    • (1994) Transfusion , vol.34 , pp. 202-208
    • MacDonald, K.L.1    Mills, W.A.2    Wood, R.C.3
  • 8
    • 0037969990 scopus 로고    scopus 로고
    • Creeping precautionism' and the blood supply
    • Moreno, J.D. (2003) 'Creeping precautionism' and the blood supply. Transfusion 43, 840-842.
    • (2003) Transfusion , vol.43 , pp. 840-842
    • Moreno, J.D.1
  • 9
    • 0025756655 scopus 로고
    • High rate of false positives in blood donor screening for antibodies to hepatitis C virus. Cause of underestimation of virus transmission rate
    • Prohaska, W., Wolff, C., Lechler, E. & Klessiek, K. (1991) High rate of false positives in blood donor screening for antibodies to hepatitis C virus. Cause of underestimation of virus transmission rate. Klin Wochenschr 3, 294-296.
    • (1991) Klin Wochenschr , vol.3 , pp. 294-296
    • Prohaska, W.1    Wolff, C.2    Lechler, E.3    Klessiek, K.4
  • 10
    • 0028266157 scopus 로고
    • Diagnosis of hepatitis C virus infection using two second generation enzyme immunoassays with a recombinant immuno blot assay for confirmation
    • Sneeberger, P., van der Nat, H., van Dijk, W.&van Loon, A. (1994) Diagnosis of hepatitis C virus infection using two second generation enzyme immunoassays with a recombinant immuno blot assay for confirmation. Eur J Clin Micrbiol Infect Dis 13, 118-121.
    • (1994) Eur J Clin Micrbiol Infect Dis , vol.13 , pp. 118-121
    • Sneeberger, P.1    van der Nat, H.2    van Dijk, W.3    van Loon, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.