Volumn 7 VOLS, Issue , 2005, Pages 406-408

Development of an artificial myocardium using a covalent shape-memory alloy fiber and its cardiovascular diagnostic response

Author keywords

[No Author keywords available]

Indexed keywords

BIOELECTRIC PHENOMENA; BIOMEDICAL ENGINEERING; METABOLISM; PHYSIOLOGY; SHAPE MEMORY EFFECT;

EID: 33846919383     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/iembs.2005.1616431     Document Type: Conference Paper
Times cited : (27)

References (16)
  • 1
    • 0031844460 scopus 로고    scopus 로고
    • The registry of the international so-ciety for heart and lung transplantation: Fifteenth offi-cial report-1998
    • Hosenpud JD, et al., "The registry of the international so-ciety for heart and lung transplantation: fifteenth offi-cial report-1998," J Heart Lung Transplant, 17, pp. 656-68, 1998
    • (1998) J Heart Lung Transplant , vol.17 , pp. 656-668
    • Hosenpud, J.D.1
  • 2
    • 0037155176 scopus 로고    scopus 로고
    • Fabrication of pulsatile cardiac tissue grafts using a novel 3-dimensional cell sheet manipulation technique and temperature-responsive cell culture surfaces
    • Feb
    • Shimizu T, et al., "Fabrication of pulsatile cardiac tissue grafts using a novel 3-dimensional cell sheet manipulation technique and temperature-responsive cell culture surfaces," Circ Res, 90(3), e40, Feb 2002.
    • (2002) Circ Res , vol.90 , Issue.3
    • Shimizu, T.1
  • 3
    • 33846898852 scopus 로고    scopus 로고
    • Nitta S, et al., Application of shape memory alloy for an artificial heart driving system, MBE 83-49, pp. 45-51, 1983 (in Japanese)
    • Nitta S, et al., "Application of shape memory alloy for an artificial heart driving system," MBE 83-49, pp. 45-51, 1983 (in Japanese)
  • 4
    • 22144488074 scopus 로고    scopus 로고
    • Addition of rhythm to non-pulsatile circulation
    • Yambe T, et al., "Addition of rhythm to non-pulsatile circulation," Biomed Pharmacother, 58 Suppl 1:8145-9, 2004.
    • (2004) Biomed Pharmacother , vol.58 , Issue.SUPPL. 1 , pp. 8145-8149
    • Yambe, T.1
  • 5
    • 0142231363 scopus 로고    scopus 로고
    • Artificial myocardium with an artificial baroreflex system using nano technology
    • s
    • Yambe T, et al., "Artificial myocardium with an artificial baroreflex system using nano technology," Biomed Pharmacother, 57 Suppl 1:122s-125s, 2004.
    • (2004) Biomed Pharmacother , vol.57 , Issue.SUPPL. 1
    • Yambe, T.1
  • 6
    • 4344668514 scopus 로고    scopus 로고
    • An artificial myocardium assist system: Electrohydraulic ventricular actuation improves myocardial tissue perfusion in goats
    • Wang Q, et al., "An artificial myocardium assist system: electrohydraulic ventricular actuation improves myocardial tissue perfusion in goats," Artif Organs, 28(9), pp. 853-857, 2004.
    • (2004) Artif Organs , vol.28 , Issue.9 , pp. 853-857
    • Wang, Q.1
  • 7
    • 0002672492 scopus 로고
    • A new instrument for prolonged mechanical massage
    • Anstadt GL, et al., "A new instrument for prolonged mechanical massage," Circulation, 31(Suppl. II), p.43, 1965.
    • (1965) Circulation , vol.31 , Issue.SUPPL. II , pp. 43
    • Anstadt, G.L.1
  • 8
    • 0026021254 scopus 로고
    • Direct mechanical ventricular actruator
    • Anstadt M, et al., "Direct mechanical ventricular actruator," Resuscitation, 21, pp. 7-23, 1991.
    • (1991) Resuscitation , vol.21 , pp. 7-23
    • Anstadt, M.1
  • 9
    • 0031009652 scopus 로고    scopus 로고
    • Dynamic cardiac compression improves contractile efficiency of the heart
    • Kawaguchi O, et al., "Dynamic cardiac compression improves contractile efficiency of the heart," J Thorac Cardiovasc Surg, 113, pp. 923-31, 1997.
    • (1997) J Thorac Cardiovasc Surg , vol.113 , pp. 923-931
    • Kawaguchi, O.1
  • 10
    • 36849132052 scopus 로고
    • Effect of low-temperature phase changes on the mechanical properties of alloys near composition TiNi
    • Buehler WJ, Gilfrich J, Wiley KC, "Effect of low-temperature phase changes on the mechanical properties of alloys near composition TiNi," J Appl Phys, 34, p.1465, 1963.
    • (1963) J Appl Phys , vol.34 , pp. 1465
    • Buehler, W.J.1    Gilfrich, J.2    Wiley, K.C.3
  • 12
    • 0017212152 scopus 로고
    • Further study of NITINOL wire as contrctile artificial muscle for an artificial heart
    • Sawyer PN, et al., "Further study of NITINOL wire as contrctile artificial muscle for an artificial heart," Carrdiovasc Diseases Bull. Texas Heart Inst 3, p. 65, 1976.
    • (1976) Carrdiovasc Diseases Bull. Texas Heart Inst , vol.3 , pp. 65
    • Sawyer, P.N.1
  • 13
    • 0034122952 scopus 로고    scopus 로고
    • Non-transplant surgery for heart failure
    • Westaby S, "Non-transplant surgery for heart failure," Heart, 83: pp. 603-10, 2000
    • (2000) Heart , vol.83 , pp. 603-610
    • Westaby, S.1
  • 14
    • 0034124893 scopus 로고    scopus 로고
    • Non transplant cardiac surgery for end-stage cardiomyopathy
    • Suma H, et al. "Non transplant cardiac surgery for end-stage cardiomyopathy," J Thorac Cardiovasc Surg, 119, pp. 1233-44, 2000.
    • (2000) J Thorac Cardiovasc Surg , vol.119 , pp. 1233-1244
    • Suma, H.1
  • 15
    • 33846916767 scopus 로고    scopus 로고
    • Raman JS, et al. The mid-term results of ventricular containment (Acorn Wrap) for end-stage ischemic cardiomyopathy
    • Raman JS, et al. "The mid-term results of ventricular containment (Acorn Wrap) for end-stage ischemic cardiomyopathy
  • 16
    • 0037167698 scopus 로고    scopus 로고
    • Ventricular constraint using the cardiac support device reduces myocardial akinetic area in an ovine model of acute infarction
    • Pilla JJ, et al. "Ventricular constraint using the cardiac support device reduces myocardial akinetic area in an ovine model of acute infarction," Circulation, 106[Suppl 1], 1207-1211, 2002.
    • (2002) Circulation , vol.106 , Issue.SUPPL. 1 , pp. 1207-1211
    • Pilla, J.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.