메뉴 건너뛰기




Volumn 1268, Issue C, 2004, Pages 946-951

Usefulness of computerized scheme for differentiating benign from malignant lung nodules on high-resolution CT

Author keywords

Computer aided diagnosis (CAD); Lung nodule; Receiver operating characteristic (ROC) curve

Indexed keywords


EID: 33846912702     PISSN: 05315131     EISSN: None     Source Type: Book Series    
DOI: 10.1016/j.ics.2004.03.083     Document Type: Article
Times cited : (6)

References (8)
  • 1
    • 0032565365 scopus 로고    scopus 로고
    • Mass screening for lung cancer with mobile spiral computed tomography scanner
    • S Sone Mass screening for lung cancer with mobile spiral computed tomography scanner Lancet 351 1998 1242 1245
    • (1998) Lancet , vol.351 , pp. 1242-1245
    • Sone, S1
  • 2
    • 0033542870 scopus 로고    scopus 로고
    • Early lung cancer action project: overall design and findings from baseline screening
    • C.I Henschke Early lung cancer action project: overall design and findings from baseline screening Lancet 354 1999 99 105
    • (1999) Lancet , vol.354 , pp. 99-105
    • Henschke, C.I1
  • 3
    • 0036190266 scopus 로고    scopus 로고
    • Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers
    • S Diederich Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers Radiology 222 2002 773 781
    • (2002) Radiology , vol.222 , pp. 773-781
    • Diederich, S1
  • 4
    • 0036109223 scopus 로고    scopus 로고
    • CT screening for lung cancer: frequency and significance of part-solid and nonsolid nodules
    • C.I Henschke CT screening for lung cancer: frequency and significance of part-solid and nonsolid nodules AJR 178 2002 1053 1057
    • (2002) AJR , vol.178 , pp. 1053-1057
    • Henschke, C.I1
  • 5
    • 85120230569 scopus 로고    scopus 로고
    • Comparison of thin section CT findings in malignant and benign nodules in CT screening for lung cancer
    • F Li Comparison of thin section CT findings in malignant and benign nodules in CT screening for lung cancer Radiology 2004 (in press)
    • (2004) Radiology
    • Li, F1
  • 6
    • 85120236888 scopus 로고    scopus 로고
    • Improvement in radiologists' performance for differentiating small benign from malignant lung nodules on high-resolution CT by using computer-estimated likelihood of malignancy
    • F Li Improvement in radiologists' performance for differentiating small benign from malignant lung nodules on high-resolution CT by using computer-estimated likelihood of malignancy AJR 2004 (in press)
    • (2004) AJR
    • Li, F1
  • 7
    • 0032525017 scopus 로고    scopus 로고
    • Maximum-likelihood estimation of receiver operating (ROC) curves from continuously distributed data
    • C.E Metz B.A Herman J.H Shen Maximum-likelihood estimation of receiver operating (ROC) curves from continuously distributed data Stat. Med. 17 1998 1033 1053
    • (1998) Stat. Med. , vol.17 , pp. 1033-1053
    • Metz, C.E1    Herman, B.A2    Shen, J.H3
  • 8
    • 0026664983 scopus 로고
    • ROC rating analysis: generalization to the population of readers and cases with the jackknife method
    • D.D Dorfman K.S Berbaum C.E Metz ROC rating analysis: generalization to the population of readers and cases with the jackknife method Invest. Radiol. 27 1992 723 731
    • (1992) Invest. Radiol. , vol.27 , pp. 723-731
    • Dorfman, D.D1    Berbaum, K.S2    Metz, C.E3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.