메뉴 건너뛰기




Volumn 5, Issue SUPPL. 1, 2006, Pages

Membrane filtration for cold regions - Impact of cold water on membrane integrity monitoring tests

Author keywords

Diffusive air flow test; Low pressure membranes; Membrane integrity monitoring; Microfiltration; Pathogen removal; Pressure decay test; Ultrafiltration; Water treatment

Indexed keywords

GEOGRAPHICAL REGIONS; MICROFILTRATION; ULTRAFILTRATION; WATER; WATER TREATMENT;

EID: 33846860834     PISSN: 14962551     EISSN: None     Source Type: Journal    
DOI: 10.1139/S06-037     Document Type: Article
Times cited : (13)

References (16)
  • 3
    • 2442464761 scopus 로고    scopus 로고
    • Estimating air diffusion contribution to pressure decay during membrane integrity tests
    • Farahbakhsh, K., and Smith, D.W. 2004. Estimating air diffusion contribution to pressure decay during membrane integrity tests. J. Memb. Sci. 237(1-2): 203-212.
    • (2004) J. Memb. Sci , vol.237 , Issue.1-2 , pp. 203-212
    • Farahbakhsh, K.1    Smith, D.W.2
  • 4
    • 0002494396 scopus 로고    scopus 로고
    • Evaluation of microfiltration performance with Bacillus spore, particle count and particle index measurements
    • Toronto, Ontario, pp
    • Freeman, S.D.N., Logsdon, G.S., Harris, A.T., and Moles, A.D. 1996. Evaluation of microfiltration performance with Bacillus spore, particle count and particle index measurements. Proceedings of the AWWA Annual Conference, Toronto, Ontario, pp. 1013-1039.
    • (1996) Proceedings of the AWWA Annual Conference , pp. 1013-1039
    • Freeman, S.D.N.1    Logsdon, G.S.2    Harris, A.T.3    Moles, A.D.4
  • 5
    • 0032442261 scopus 로고    scopus 로고
    • Experimental assessment of the efficacy of microfiltration and ultrafiltration for Cryptosporidium removal
    • Hirata, T., and Hashimoto, A. 1998. Experimental assessment of the efficacy of microfiltration and ultrafiltration for Cryptosporidium removal. Water Sci. Technol. 38: 103-107.
    • (1998) Water Sci. Technol , vol.38 , pp. 103-107
    • Hirata, T.1    Hashimoto, A.2
  • 6
    • 0021222567 scopus 로고
    • Integrity testing of microfiltration membranes
    • Hofman, F. 1984. Integrity testing of microfiltration membranes. J. Parenter. Sci. Technol. 38: 148-158.
    • (1984) J. Parenter. Sci. Technol , vol.38 , pp. 148-158
    • Hofman, F.1
  • 10
    • 0036957784 scopus 로고    scopus 로고
    • Evaluation of membrane filtration for Los Angeles' open reservoirs
    • Karimi, A.A., Adham, S., and Tu, S.-C. 2002. Evaluation of membrane filtration for Los Angeles' open reservoirs. J. Am. Water Works Assoc. 94: 120-128.
    • (2002) J. Am. Water Works Assoc , vol.94 , pp. 120-128
    • Karimi, A.A.1    Adham, S.2    Tu, S.-C.3
  • 12
    • 85021141107 scopus 로고    scopus 로고
    • The impact of cold feed waters on membrane filtration operation
    • Washington D.C
    • Uhr, D.R. 2001. The impact of cold feed waters on membrane filtration operation. Proceedings of AWWA Annual Conference, Washington D.C.
    • (2001) Proceedings of AWWA Annual Conference
    • Uhr, D.R.1
  • 13
    • 33846864693 scopus 로고    scopus 로고
    • USEPA. 2005. Membrane filtration guidance manual. EPA 815R-06-009.
    • USEPA. 2005. Membrane filtration guidance manual. EPA 815R-06-009.
  • 15
    • 84984085862 scopus 로고
    • Correlation of diffusion coefficient in dilute solutions
    • Wilke, C.R., and Chang, P. 1955. Correlation of diffusion coefficient in dilute solutions. Am Inst. Chem. Eng. J. 1: 264-270.
    • (1955) Am Inst. Chem. Eng. J , vol.1 , pp. 264-270
    • Wilke, C.R.1    Chang, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.