메뉴 건너뛰기




Volumn 51, Issue 22, 2006, Pages 5927-5936

Development of an easy-to-handle range measurement tool using a plastic scintillator for proton beam therapy

Author keywords

[No Author keywords available]

Indexed keywords

CHARGE COUPLED DEVICES; DOSIMETRY; IONIZATION CHAMBERS; PATIENT TREATMENT; PHOSPHORS; PROTON IRRADIATION; TUMORS;

EID: 33846860629     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/51/22/014     Document Type: Article
Times cited : (29)

References (10)
  • 1
    • 0026804696 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations
    • Bedder A S, Mackie T R and Attix F H 1992 Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations Phys. Med. Biol 37 1883-900
    • (1992) Phys. Med. Biol , vol.37 , Issue.10 , pp. 1883-1900
    • Bedder, A.S.1    MacKie, T.R.2    Attix, F.H.3
  • 4
    • 0033735266 scopus 로고    scopus 로고
    • Performance of a fluorescent screen and CCD camera as a two-dimensional dosimetry system for dynamic treatment techniques
    • Boon S N, van Luijk P, Böhringer T, Coray A, Lomax A J, Pedroni E, Schaffner B and Schippers J M 2000 Performance of a fluorescent screen and CCD camera as a two-dimensional dosimetry system for dynamic treatment techniques Med. Phys. 27 2198-208
    • (2000) Med. Phys. , vol.27 , Issue.10 , pp. 2198-2208
    • Boon, S.N.1    Van Luijk, P.2    Böhringer, T.3    Coray, A.4    Lomax, A.J.5    Pedroni, E.6    Schaffner, B.7    Schippers, J.M.8
  • 5
    • 0032726570 scopus 로고    scopus 로고
    • An application of GafChromic MD-55 film for 67.5 MeV clinical proton beam dosimetry
    • Daftari I, Castenadas C, Petti P L, Singh R P and Verhey L J 1999 An application of GafChromic MD-55 film for 67.5 MeV clinical proton beam dosimetry Phys. Med. Biol. 44 2735-45
    • (1999) Phys. Med. Biol. , vol.44 , Issue.11 , pp. 2735-2745
    • Daftari, I.1    Castenadas, C.2    Petti, P.L.3    Singh, R.P.4    Verhey, L.J.5
  • 7
    • 33644695957 scopus 로고    scopus 로고
    • ICRU 1998 Clinical proton dosimetry: part I. Beam production, beam delivery and measurement of absorbed dose ICRU Report 59 (Bethesda, MD: International Commission on Radiation Units and Measurements)
    • (1998) ICRU Report 59
    • Icru1
  • 8
    • 0034516224 scopus 로고    scopus 로고
    • Depth ionization curves for an unmodulated proton beam measured with different ionization chambers
    • Mobit P N, Sandison G A and Bloch C 2000 Depth ionization curves for an unmodulated proton beam measured with different ionization chambers Med. Phys. 27 2780-7
    • (2000) Med. Phys. , vol.27 , Issue.12 , pp. 2780-2787
    • Mobit, P.N.1    Sandison, G.A.2    Bloch, C.3
  • 9
    • 0033863116 scopus 로고    scopus 로고
    • Radiochromic film dosimetry of a low energy proton beam
    • Piermattei A et al 2000 Radiochromic film dosimetry of a low energy proton beam Med. Phys. 27 1655-60
    • (2000) Med. Phys. , vol.27 , Issue.7 , pp. 1655-1660
    • Piermattei, A.1    Al, E.2
  • 10
    • 5744234410 scopus 로고    scopus 로고
    • Development of an inorganic scintillating mixture for proton beam verification dosimetry
    • Sarios S, Shixiong L and Eros P 2004 Development of an inorganic scintillating mixture for proton beam verification dosimetry Phys. Med. Biol 49 4637-55
    • (2004) Phys. Med. Biol , vol.49 , Issue.19 , pp. 4637-4655
    • Sarios, S.1    Shixiong, L.2    Eros, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.