메뉴 건너뛰기




Volumn 52, Issue 6, 2006, Pages 395-400

Metabolic / glycemic control accuracy, effect and complications of the continuous glucose monitoring system in diabetic patients;Impacto do sistema de monitorização contínua da glicose em pacientes diabéticos

Author keywords

Capillary glycemia; CGMS; Diabetes mellitus

Indexed keywords

ADOLESCENT; ADULT; AGED; AMBULATORY MONITORING; ARTICLE; BLOOD; BLOOD GLUCOSE MONITORING; CAPILLARY; CHILD; DIABETES MELLITUS; FEMALE; GLUCOSE BLOOD LEVEL; GLUCOSE TOLERANCE TEST; HUMAN; HYPERGLYCEMIA; HYPOGLYCEMIA; MALE; MIDDLE AGED; PRESCHOOL CHILD; REFERENCE VALUE; RETROSPECTIVE STUDY; STANDARD;

EID: 33846794903     PISSN: 01044230     EISSN: None     Source Type: Journal    
DOI: 10.1590/S0104-42302006000600017     Document Type: Article
Times cited : (7)

References (22)
  • 1
    • 17844405085 scopus 로고    scopus 로고
    • Glicemia capilar em ponta do dedo versus lóbulo de orelha: Estudo comparativo dos valores resultantes e preferências dos pacientes
    • Ferraz DP, Maia FFR, Araújo LR. Glicemia capilar em ponta do dedo versus lóbulo de orelha: estudo comparativo dos valores resultantes e preferências dos pacientes. Arq Bras Endocrinol Metab. 2004;48:389-93.
    • (2004) Arq Bras Endocrinol Metab , vol.48 , pp. 389-393
    • Ferraz, D.P.1    Maia, F.F.R.2    Araújo, L.R.3
  • 2
    • 0030896255 scopus 로고    scopus 로고
    • Quality of life and associated characteristics in a large national sample of adults with diabetes
    • Glasgow RE, Eakin EG. Quality of life and associated characteristics in a large national sample of adults with diabetes. Diabetes Care. 1997;20:562-7.
    • (1997) Diabetes Care , vol.20 , pp. 562-567
    • Glasgow, R.E.1    Eakin, E.G.2
  • 3
    • 0035374580 scopus 로고    scopus 로고
    • The prevalence of comorbid depression in adults with diabetes: A meta-analysis
    • Anderson RJ, Freedland KE, Clouse RE, Iustman PJ. The prevalence of comorbid depression in adults with diabetes: a meta-analysis. Diabetes Care. 2001;24:1069-78.
    • (2001) Diabetes Care , vol.24 , pp. 1069-1078
    • Anderson, R.J.1    Freedland, K.E.2    Clouse, R.E.3    Iustman, P.J.4
  • 4
    • 0034493821 scopus 로고    scopus 로고
    • Role of continuous glucose monitoring in pediatric patients
    • Kaufman FR. Role of continuous glucose monitoring in pediatric patients. Diabetes Technol Ther. 2000;2:S49-52.
    • (2000) Diabetes Technol Ther , vol.2
    • Kaufman, F.R.1
  • 5
    • 0034492952 scopus 로고    scopus 로고
    • Continuous glucose monitoring in youth with type 2 diabetes: Overcoming barriers to successful treatment
    • Boland EA, Tamborlane VW. Continuous glucose monitoring in youth with type 2 diabetes: overcoming barriers to successful treatment. Diabetes Technol Ther 2000;2:S53-9.
    • (2000) Diabetes Technol Ther , vol.2
    • Boland, E.A.1    Tamborlane, V.W.2
  • 6
    • 0242357278 scopus 로고    scopus 로고
    • First human experiments with a non-invasive, non-optical continuous glucose monitoring system
    • Caduff A, Hirt E, Feldman Y, Ali Z, Heinemann L. First human experiments with a non-invasive, non-optical continuous glucose monitoring system. Biosens Bioelecton. 2003;19:209-7.
    • (2003) Biosens Bioelecton , vol.19 , pp. 209-207
    • Caduff, A.1    Hirt, E.2    Feldman, Y.3    Ali, Z.4    Heinemann, L.5
  • 7
    • 0034004142 scopus 로고    scopus 로고
    • Interstitial glucose concentration and glycemia: Impiclations for continuous subcutaneous glucose monitoring
    • Aussedat B, Dupire-Angel M, Gifford R, Klein JC, Wilson GS, Reach G. Interstitial glucose concentration and glycemia: impiclations for continuous subcutaneous glucose monitoring. Endocrinol Metab. 2000;278:E716-E28.
    • (2000) Endocrinol Metab , vol.278
    • Aussedat, B.1    Dupire-Angel, M.2    Gifford, R.3    Klein, J.C.4    Wilson, G.S.5    Reach, G.6
  • 8
    • 1542439960 scopus 로고    scopus 로고
    • Performance assessment of the Medtronic-Minimed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in Type 1 diabetic subjects
    • Sachedina N, Pickup JC. Performance assessment of the Medtronic-Minimed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in Type 1 diabetic subjects. Diabet Metab. 2003;20:1012-5.
    • (2003) Diabet Metab , vol.20 , pp. 1012-1015
    • Sachedina, N.1    Pickup, J.C.2
  • 9
    • 17144458994 scopus 로고    scopus 로고
    • Accuracy of the continuous glucose monitoring system in inpatient and outpatient conditions
    • Djakoure-Platonoff C, Radermercker R, Reach G, Slama G, Selam JI. Accuracy of the continuous glucose monitoring system in inpatient and outpatient conditions. Diabetes Metab. 2003;29(2 Pt 1):159-62.
    • (2003) Diabetes Metab , vol.29 , Issue.2 PART 1 , pp. 159-162
    • Djakoure-Platonoff, C.1    Radermercker, R.2    Reach, G.3    Slama, G.4    Selam, J.I.5
  • 10
    • 0041666413 scopus 로고    scopus 로고
    • Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs
    • Guerci B, Floriot M, Bohme P, Durain D, Benichou M, Jellimann S, et al. Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs. Diabetes Care. 2003;26: 582-9.
    • (2003) Diabetes Care , vol.26 , pp. 582-589
    • Guerci, B.1    Floriot, M.2    Bohme, P.3    Durain, D.4    Benichou, M.5    Jellimann, S.6
  • 11
    • 21244434882 scopus 로고    scopus 로고
    • Diabetes Research in Children Network Study Group. Eight point glucose testing versus the continuous glucose monitoring system in evaluation of glycemic control in type 1 diabetes
    • Fiallo-Scharer R. Diabetes Research in Children Network Study Group. Eight point glucose testing versus the continuous glucose monitoring system in evaluation of glycemic control in type 1 diabetes. J Clin Endocrinol Metab. 2005;90:3387-91.
    • (2005) J Clin Endocrinol Metab , vol.90 , pp. 3387-3391
    • Fiallo-Scharer, R.1
  • 12
    • 1442275324 scopus 로고    scopus 로고
    • Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia. Experience of the Diabetes Research in Children Network (DirecNet)
    • Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia. Experience of the Diabetes Research in Children Network (DirecNet). Diabetes Care. 2004;27:722-6.
    • (2004) Diabetes Care , vol.27 , pp. 722-726
  • 13
    • 0038643466 scopus 로고    scopus 로고
    • Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: A controlled crossover study
    • Ludvigsson J, Hanas R. Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: a controlled crossover study. Pediatrics. 2003;111(5 Pt 1):933-8.
    • (2003) Pediatrics , vol.111 , Issue.5 PART 1 , pp. 933-938
    • Ludvigsson, J.1    Hanas, R.2
  • 14
    • 0345862180 scopus 로고    scopus 로고
    • Improved metabolic control in diabetic adolescents using the continuous glucose monitoring system (CGMS)
    • Schaepelynck-Belicar P, Bague P, Simonin G, Lassmann-Vague V. Improved metabolic control in diabetic adolescents using the continuous glucose monitoring system (CGMS). Diabetes Metab. 2003;29:608-12.
    • (2003) Diabetes Metab , vol.29 , pp. 608-612
    • Schaepelynck-Belicar, P.1    Bague, P.2    Simonin, G.3    Lassmann-Vague, V.4
  • 15
    • 0242268979 scopus 로고    scopus 로고
    • The Accuracy of the CGMS in children with type 1 diabetes: Results of the Diabetes Research in Children Network (DirecNet)
    • The Accuracy of the CGMS in children with type 1 diabetes: results of the Diabetes Research in Children Network (DirecNet). Diabetes Technol Ther. 2003;5:781-9.
    • (2003) Diabetes Technol Ther , vol.5 , pp. 781-789
  • 16
    • 0037278431 scopus 로고    scopus 로고
    • Determination of plasma glucose during rapid glucose excursions with a subcutaneous glucose sensor
    • Steil GM, Rebrin K, Mastrototaro J, Bernaba B, Saad MF. Determination of plasma glucose during rapid glucose excursions with a subcutaneous glucose sensor. Diabetes Technol Ther. 2003;5:27-31.
    • (2003) Diabetes Technol Ther , vol.5 , pp. 27-31
    • Steil, G.M.1    Rebrin, K.2    Mastrototaro, J.3    Bernaba, B.4    Saad, M.F.5
  • 17
    • 0036728499 scopus 로고    scopus 로고
    • Spurius reporting of nocturnal hypoglycemia by CGMS in patients with thigthtyle controlled diabetes
    • McGowan K, Tomas W, Moran A. Spurius reporting of nocturnal hypoglycemia by CGMS in patients with thigthtyle controlled diabetes. Diabetes Care. 2002;25:1499-503.
    • (2002) Diabetes Care , vol.25 , pp. 1499-1503
    • McGowan, K.1    Tomas, W.2    Moran, A.3
  • 18
    • 0036632394 scopus 로고    scopus 로고
    • Reproductibility of glucose measurements using the glucose sensor
    • Metzger M, Leibowitz G, Waistein J, Glaser B, Raz I. Reproductibility of glucose measurements using the glucose sensor. Diabetes Care. 2002;25:1185-91.
    • (2002) Diabetes Care , vol.25 , pp. 1185-1191
    • Metzger, M.1    Leibowitz, G.2    Waistein, J.3    Glaser, B.4    Raz, I.5
  • 19
    • 0035514022 scopus 로고    scopus 로고
    • Limitations of conventional methods of self-monitoring of blood glucose: Lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes
    • Boland E, Monsod T, Delucia M, Brandt CA, Fernando S, Tamborlane VW. Limitations of conventional methods of self-monitoring of blood glucose: lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes. Diabetes Care. 2001;24:1858-62.
    • (2001) Diabetes Care , vol.24 , pp. 1858-1862
    • Boland, E.1    Monsod, T.2    Delucia, M.3    Brandt, C.A.4    Fernando, S.5    Tamborlane, V.W.6
  • 20
    • 0042490765 scopus 로고    scopus 로고
    • The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control
    • Chico A, Vidal-Rios P, Subira M, Novials A. The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control. Diabetes Care. 2003;26:1153-7.
    • (2003) Diabetes Care , vol.26 , pp. 1153-1157
    • Chico, A.1    Vidal-Rios, P.2    Subira, M.3    Novials, A.4
  • 21
    • 9444290443 scopus 로고    scopus 로고
    • Continuous glucose monitoring and the reality metabolic control in preschool children with type 1 diabetes
    • Jeha GS, Karaviti PL, Anderson B, Smith EO, Donaldson S, Mc Girk TS, et al. Continuous glucose monitoring and the reality metabolic control in preschool children with type 1 diabetes. Diabetes Care. 2004;27:2881-6.
    • (2004) Diabetes Care , vol.27 , pp. 2881-2886
    • Jeha, G.S.1    Karaviti, P.L.2    Anderson, B.3    Smith, E.O.4    Donaldson, S.5    Mc Girk, T.S.6
  • 22
    • 28244499529 scopus 로고    scopus 로고
    • Maia FFR, Araújo LR. Accuracy, utility and complications of continuous glucose monitoring system (CGMS) in pediatric patients with type 1 diabetes. J Pediatr. (Rio J) 2005;81:293-7.
    • Maia FFR, Araújo LR. Accuracy, utility and complications of continuous glucose monitoring system (CGMS) in pediatric patients with type 1 diabetes. J Pediatr. (Rio J) 2005;81:293-7.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.