메뉴 건너뛰기




Volumn 3, Issue , 2005, Pages 1524-1529

Design simulation of a rotating dual-headed PET/CT scanner for breast imaging

Author keywords

[No Author keywords available]

Indexed keywords

ANTHROPOMORPHIC ACTIVITY; ATTENUATION DISTRIBUTION; BREAST IMAGING; DESIGN SIMULATION;

EID: 33846649450     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2005.1596608     Document Type: Conference Paper
Times cited : (15)

References (8)
  • 1
    • 0035355148 scopus 로고    scopus 로고
    • maxPET: A Dedicated Mammary and Axillary Region PET Imaging System for Breast Cancer
    • Doshi NK, Silverman RW, Shao Y and Cherry SR "maxPET: A Dedicated Mammary and Axillary Region PET Imaging System for Breast Cancer" IEEE Trans. Nucl. Sci. 48 (3): 811-815, 2001
    • (2001) IEEE Trans. Nucl. Sci , vol.48 , Issue.3 , pp. 811-815
    • Doshi, N.K.1    Silverman, R.W.2    Shao, Y.3    Cherry, S.R.4
  • 2
    • 0035190741 scopus 로고    scopus 로고
    • Dedicated Breast CT: Radiation dose and image quality evaluation
    • Boone JM, Nelson TR, Lindfors KK, and Seibert JA, "Dedicated Breast CT: Radiation dose and image quality evaluation", Radiology 221: 657-667, 2001
    • (2001) Radiology , vol.221 , pp. 657-667
    • Boone, J.M.1    Nelson, T.R.2    Lindfors, K.K.3    Seibert, J.A.4
  • 3
    • 5744251917 scopus 로고    scopus 로고
    • Jan S, Santin G, Strul D, Staelens S, Assie K, Autret D, Avner S, Barbier R, Bardies M, Bloomfield PM, Brasse D, Breton V, Bruyndonckx P, Buvat I, Chatziioannou AF, Choi Y, Chung YH, Comtat C, Donnarieix D, Ferrer L, Glick SJ, Groiselle CJ, Guez D, Honore PF, Kerhoas-Cavata S, Kirov AS, Kohli V, Koole M, Krieguer M, van der Laan DJ, Lamare F, Largeron G, Lartizien C, Lazaro D, Maas MC, Maigne L, Mayet F, Melot F, Merheb C, Pennacchio E, Perez J, Pietrzyk U, Rannou FR, Rey M, Schaart DR, Schmidtlein CR, Simon L, Song TY, Vieira JM, Visvikis D, de Walle RV, Wieers E and Morel C GATE: A simulation toolkit for PET and SPECT Phys. Med. Biol. 49: 4543-4561, 2004
    • Jan S, Santin G, Strul D, Staelens S, Assie K, Autret D, Avner S, Barbier R, Bardies M, Bloomfield PM, Brasse D, Breton V, Bruyndonckx P, Buvat I, Chatziioannou AF, Choi Y, Chung YH, Comtat C, Donnarieix D, Ferrer L, Glick SJ, Groiselle CJ, Guez D, Honore PF, Kerhoas-Cavata S, Kirov AS, Kohli V, Koole M, Krieguer M, van der Laan DJ, Lamare F, Largeron G, Lartizien C, Lazaro D, Maas MC, Maigne L, Mayet F, Melot F, Merheb C, Pennacchio E, Perez J, Pietrzyk U, Rannou FR, Rey M, Schaart DR, Schmidtlein CR, Simon L, Song TY, Vieira JM, Visvikis D, de Walle RV, Wieers E and Morel C "GATE: A simulation toolkit for PET and SPECT" Phys. Med. Biol. 49: 4543-4561, 2004
  • 4
    • 0035246235 scopus 로고    scopus 로고
    • Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms
    • Segars WP, Lalush DS, Tsui BMW "Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms" IEEE Trans Nuc Sci 48(1), 89-97, 2001
    • (2001) IEEE Trans Nuc Sci , vol.48 , Issue.1 , pp. 89-97
    • Segars, W.P.1    Lalush, D.S.2    Tsui, B.M.W.3
  • 5
    • 13244295721 scopus 로고    scopus 로고
    • Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors
    • Judenhofer MS, Pichler BJ and Cherry SR "Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors" Phys. Med. Biol 50, 29-44, 2005
    • (2005) Phys. Med. Biol , vol.50 , pp. 29-44
    • Judenhofer, M.S.1    Pichler, B.J.2    Cherry, S.R.3
  • 6
    • 0035114719 scopus 로고    scopus 로고
    • FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection
    • Ramos CD, Erdi Y, Conen CM et al "FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection" Eur J Nucl Med, 28(2): 155-64, 2001.
    • (2001) Eur J Nucl Med , vol.28 , Issue.2 , pp. 155-164
    • Ramos, C.D.1    Erdi, Y.2    Conen, C.M.3
  • 7
    • 0025414253 scopus 로고
    • Measuring PET Scanner Sensitivity - Relating Countrates to Image Signal-to-Noise Ratios Using Noise Equivalent Counts
    • Strother, S.C., M.E. Casey, and E.J. Hoffman "Measuring PET Scanner Sensitivity - Relating Countrates to Image Signal-to-Noise Ratios Using Noise Equivalent Counts" IEEE Trans Nucl Sci, 37(2): 783-788, 1990.
    • (1990) IEEE Trans Nucl Sci , vol.37 , Issue.2 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 8
    • 0142063357 scopus 로고    scopus 로고
    • GATE: A Geant4-based simulation platform for PET and SPECT integrating movement and time management
    • Oct
    • Santin G, Strul D, Lazaro D, Simon L, Krieguer M, Martins MV, Breton V and Morel C "GATE: A Geant4-based simulation platform for PET and SPECT integrating movement and time management" IEEE Trans Nucl. Sci. 50 (5): 1516-1521 Part 2, Oct 2003
    • (2003) IEEE Trans Nucl. Sci , vol.50 , Issue.5 PART 2 , pp. 1516-1521
    • Santin, G.1    Strul, D.2    Lazaro, D.3    Simon, L.4    Krieguer, M.5    Martins, M.V.6    Breton, V.7    Morel, C.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.