-
1
-
-
0007518930
-
Experiments with medium Z materials for shielding against low-energy x-rays
-
E. W. Webster, " Experiments with medium Z materials for shielding against low-energy x-rays., " Radiology 86, 146 (1966).
-
(1966)
Radiology
, vol.86
, pp. 146
-
-
Webster, E.W.1
-
2
-
-
0025909731
-
Composite materials for x-ray protection
-
M. J. Yaffe, G. E. Mawdsley, L. Martin, R. Servant, and R. George, " Composite materials for x-ray protection., " Health Phys. 60, 661-664 (1991).
-
(1991)
Health Phys.
, vol.60
, pp. 661-664
-
-
Yaffe, M.J.1
Mawdsley, G.E.2
Martin, L.3
Servant, R.4
George, R.5
-
3
-
-
0027529683
-
Attenuation properties of lead composite aprons
-
P. H. Murphy, Y. Wu, and S. A. Glaze, " Attenuation properties of lead composite aprons., " Radiology 186, 269-272 (1993).
-
(1993)
Radiology
, vol.186
, pp. 269-272
-
-
Murphy, P.H.1
Wu, Y.2
Glaze, S.A.3
-
4
-
-
0028864708
-
Effectiveness of lead aprons in vascular radiology: Results of clinical measurements
-
P. J. Kicken and A. J. J. Bos, " Effectiveness of lead aprons in vascular radiology: Results of clinical measurements., " Radiology 197, 473-478 (1995).
-
(1995)
Radiology
, vol.197
, pp. 473-478
-
-
Kicken, P.J.1
Bos, A.J.J.2
-
5
-
-
0037701348
-
Evaluation of the transmitted exposure through lead equivalent aprons used in a radiology department, including contribution from backscatter
-
E. G. Christodoulou, M. M. Soodsitt, S. C. Larson, K. L. Darner, J. Satti, and H.-P. Chan, " Evaluation of the transmitted exposure through lead equivalent aprons used in a radiology department, including contribution from backscatter., " Med. Phys. 30, 1033-1038 (2003).
-
(2003)
Med. Phys.
, vol.30
, pp. 1033-1038
-
-
Christodoulou, E.G.1
Soodsitt, M.M.2
Larson, S.C.3
Darner, K.L.4
Satti, J.5
Chan, H.-P.6
-
6
-
-
24944439970
-
Experimental and theoretical studies on radiation protective effect of a lighter non-lead protective apron
-
Y. Takano, K. Okazaki, K. Ono, and M. Kai, " Experimental and theoretical studies on radiation protective effect of a lighter non-lead protective apron., " Nippon Hoshasen Gijutsu Gakkai Zasshi (Jpn. J. Radiol. Technol.) 61, 1027-1032 (2005) (in Japanese).
-
(2005)
Nippon Hoshasen Gijutsu Gakkai Zasshi (Jpn. J. Radiol. Technol.)
, vol.61
, pp. 1027-1032
-
-
Takano, Y.1
Okazaki, K.2
Ono, K.3
Kai, M.4
-
9
-
-
0034104708
-
Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
-
I. Kawrakow, " Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version., " Med. Phys. 27, 485-498 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 485-498
-
-
Kawrakow, I.1
-
10
-
-
0003797114
-
-
PIRS-701, 4th printing, National Research Council of Canada, Ottawa, Canada
-
I. Kawrakow and D. W. O. Rogers, " The EGSnrc Code System: Monte Carlo simulation of electron and photon transport., " Technical Report No. PIRS-701, 4th printing, National Research Council of Canada, Ottawa, Canada, 2003.
-
(2003)
The EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport
-
-
Kawrakow, I.1
Rogers, D.W.O.2
-
11
-
-
33746660928
-
-
PIRS 898, National Research Council of Canada, Ottawa, Canada
-
I. Kawrakow, " EGSnrc C++ class library., " Technical Report No. PIRS 898, National Research Council of Canada, Ottawa, Canada, 2005.
-
(2005)
EGSnrc C++ Class Library
-
-
Kawrakow, I.1
-
12
-
-
33746607672
-
Efficient x-ray tube simulations
-
E. Mainegra-Hing and I. Kawrakow, " Efficient x-ray tube simulations., " Med. Phys. 33 (8), 2683-2690 (2006).
-
(2006)
Med. Phys.
, vol.33
, Issue.8
, pp. 2683-2690
-
-
Mainegra-Hing, E.1
Kawrakow, I.2
-
15
-
-
0003966102
-
-
M. J. Berger, J. H. Hubbell, S. M. Seltzer, J. Chang, and J. S. Coursey, " XCOM: Photon Cross-Section Database., " NIST, http://physics.nist. gov/PhysRefData/Xcom/Text/XCOM.html (1990).
-
(1990)
XCOM: Photon Cross-Section Database
-
-
Berger, M.J.1
Hubbell, J.H.2
Seltzer, S.M.3
Chang, J.4
Coursey, J.S.5
-
16
-
-
0018399326
-
Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector
-
R. Birch and M. Marshall, " Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector., " Phys. Med. Biol. 24, 505-517 (1979).
-
(1979)
Phys. Med. Biol.
, vol.24
, pp. 505-517
-
-
Birch, R.1
Marshall, M.2
-
18
-
-
85027238959
-
-
International Commission on Radiation Units and Measurements, ICRU Report No. 51
-
International Commission on Radiation Units and Measurements, ICRU Report No. 51 (1993).
-
(1993)
-
-
-
19
-
-
0024355954
-
Experimentally determined backscatter factors for x rays generated at voltages between 16 and 140 kV
-
S. C. Klevenhagen, " Experimentally determined backscatter factors for x rays generated at voltages between 16 and 140 kV., " Phys. Med. Biol. 34, 1871-1882 (1989).
-
(1989)
Phys. Med. Biol.
, vol.34
, pp. 1871-1882
-
-
Klevenhagen, S.C.1
|