Volumn 5, Issue , 2005, Pages 2542-2546

A new approach of dynamic pinhole SPECT imaging for evaluation of sympathetic nervous system function in animal models of cardiac hypertrophy

Author keywords

[No Author keywords available]

Indexed keywords

CARDIAC HYPERTROPHY; NONLINEAR POINT PROJECTION FITTING METHODS; PHANTOMS; SPONTANEOUS HYPERTENSIVE RATS (SHR);

EID: 33846645055     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2005.1596857     Document Type: Conference Paper
Times cited : (4)

References (7)
  • 1
    • 0028947435 scopus 로고
    • Editorial-Scintigraphy of myocardial innervation with metaiodobenzylguanidine (MIBG): Is there a clinical application?
    • M. W. Dae, "Editorial-Scintigraphy of myocardial innervation with metaiodobenzylguanidine (MIBG): Is there a clinical application?" J. Nucl. Cardiol., vol. 2, pp. 151-154, 1995.
    • (1995) J. Nucl. Cardiol , vol.2 , pp. 151-154
    • Dae, M.W.1
  • 2
    • 0023519549 scopus 로고
    • Estimation of geometrical parameters for fan beam tomography
    • G. T. Gullberg, B. M. W. Tsui, C. Crawford, and E. Edgerton, "Estimation of geometrical parameters for fan beam tomography," Phys. Med. Biol., vol. 32, pp. 1581-94, 1987.
    • (1987) Phys. Med. Biol , vol.32 , pp. 1581-1594
    • Gullberg, G.T.1    Tsui, B.M.W.2    Crawford, C.3    Edgerton, E.4
  • 4
    • 0031981253 scopus 로고    scopus 로고
    • High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner
    • J. Qi, R. M. Leahy, S. R. Cherry, A. Chatziioannou, and T. H. Farquhar, "High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner," Phys. Med. Biol., vol. 43, pp. 1001-13, 1998.
    • (1998) Phys. Med. Biol , vol.43 , pp. 1001-1013
    • Qi, J.1    Leahy, R.M.2    Cherry, S.R.3    Chatziioannou, A.4    Farquhar, T.H.5
  • 5
    • 0018861279 scopus 로고
    • The use of principal components in the quantitative analysis of gamma camera dynamic studies
    • D.C. Barber, "The use of principal components in the quantitative analysis of gamma camera dynamic studies," Phys. Med. Biol., vol. 25, pp. 283-92, 1980.
    • (1980) Phys. Med. Biol , vol.25 , pp. 283-292
    • Barber, D.C.1
  • 6
    • 0035212751 scopus 로고    scopus 로고
    • Reconstruction of dynamic renal tomographic data acquired by slow rotation
    • A. Sitek, G. T. Gullberg, E. V. Di Bella, and A. Celler, "Reconstruction of dynamic renal tomographic data acquired by slow rotation," J. Nucl. Med., vol. 42, pp. 1704-12, 2001
    • (2001) J. Nucl. Med , vol.42 , pp. 1704-1712
    • Sitek, A.1    Gullberg, G.T.2    Di Bella, E.V.3    Celler, A.4
  • 7
    • 0033804685 scopus 로고    scopus 로고
    • Factor analysis with a priori knowledge-application in dynamic cardiac SPECT
    • A. Sitek, E. V. Di Bella, and G. T. Gullberg, "Factor analysis with a priori knowledge-application in dynamic cardiac SPECT," Phys. Med. Biol., vol. 45, pp. 2619-38, 2000.
    • (2000) Phys. Med. Biol , vol.45 , pp. 2619-2638
    • Sitek, A.1    Di Bella, E.V.2    Gullberg, G.T.3