메뉴 건너뛰기




Volumn 5, Issue , 2005, Pages 2514-2518

Performance evaluation of the low-cost high-sensitivity Rodent Research PET (RRPET) camera using Monte Carlo simulations

Author keywords

[No Author keywords available]

Indexed keywords

BIODIVERSITY; CAMERAS; COMPUTER SIMULATION; IMAGING SYSTEMS; MONTE CARLO METHODS; OPTICAL RESOLVING POWER;

EID: 33846643673     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2005.1596851     Document Type: Conference Paper
Times cited : (5)

References (9)
  • 1
    • 0033050169 scopus 로고    scopus 로고
    • Small-animal PET: Advent of a new era of PET research
    • Jul
    • M. Tornai, R. Jaszczak, T. Turkington and R. Coleman, "Small-animal PET: Advent of a new era of PET research," J. Nucl. Med., vol. 40, no. 7, pp. 1176-1179, Jul. 1999.
    • (1999) J. Nucl. Med , vol.40 , Issue.7 , pp. 1176-1179
    • Tornai, M.1    Jaszczak, R.2    Turkington, T.3    Coleman, R.4
  • 3
    • 20244389194 scopus 로고    scopus 로고
    • A pentagon Photomultiplier-Quadrant-Sharing BGO detector for a Rodent Research PET (RRPET)
    • Feb
    • S. Xie, R. Ramirez, Y. Liu, T. Xing, J. Uribe, H. Li, et al.; "A pentagon Photomultiplier-Quadrant-Sharing BGO detector for a Rodent Research PET (RRPET)," IEEE Trans. Nucl. Sci., vol. 52, no. 1, pp. 210-216, Feb. 2005.
    • (2005) IEEE Trans. Nucl. Sci , vol.52 , Issue.1 , pp. 210-216
    • Xie, S.1    Ramirez, R.2    Liu, Y.3    Xing, T.4    Uribe, J.5    Li, H.6
  • 4
    • 0027644358 scopus 로고
    • A positron camera detector design with cross-coupled scintillatiors and quadrant sharing photomultipliers
    • Aug
    • W.-H. Wong, "A positron camera detector design with cross-coupled scintillatiors and quadrant sharing photomultipliers," IEEE Trans. Nucl. Sci., vol. 40, no. 4, pp. 962-966, Aug. 1993.
    • (1993) IEEE Trans. Nucl. Sci , vol.40 , Issue.4 , pp. 962-966
    • Wong, W.-H.1
  • 5
    • 0036071435 scopus 로고    scopus 로고
    • Monte Carlo simulations in SPECT and PET
    • Mar
    • I. Buvat, I. Castiglioni, "Monte Carlo simulations in SPECT and PET," Q J Nucl. Med., vol. 46, pp. 48-61, Mar. 2002.
    • (2002) Q J Nucl. Med , vol.46 , pp. 48-61
    • Buvat, I.1    Castiglioni, I.2
  • 8
    • 0036816137 scopus 로고    scopus 로고
    • A New Pileup-Prevention Front-End Electronic Design for High-Resolution PET and Gamma Cameras
    • Oct
    • H. Li, W.-H. Wong, J. Uribe, H. Baghaei, Y. Liu, Y. Wang, et al., "A New Pileup-Prevention Front-End Electronic Design for High-Resolution PET and Gamma Cameras," IEEE Trans. Nucl. Sci., vol. 49, no. 5, pp. 2051-2056, Oct. 2002.
    • (2002) IEEE Trans. Nucl. Sci , vol.49 , Issue.5 , pp. 2051-2056
    • Li, H.1    Wong, W.-H.2    Uribe, J.3    Baghaei, H.4    Liu, Y.5    Wang, Y.6
  • 9
    • 0033059817 scopus 로고    scopus 로고
    • Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution
    • C. Levin and E. Huffman, "Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution," Phys. Med. Biol., vol. 44, pp. 781-799, 1999.
    • (1999) Phys. Med. Biol , vol.44 , pp. 781-799
    • Levin, C.1    Huffman, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.