메뉴 건너뛰기




Volumn 5, Issue , 2005, Pages 2686-2689

Evaluation of MAP image reconstruction with positron range modeling for 3D PET

Author keywords

[No Author keywords available]

Indexed keywords

IMAGE NOISE; POSITRON RANGE;

EID: 33846629139     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2005.1596890     Document Type: Conference Paper
Times cited : (22)

References (7)
  • 1
    • 0033059817 scopus 로고    scopus 로고
    • Calculation of Positron Range and Its Effect on the Fundamental Limit of Positron Emission Tomography System Spatial Resolution
    • C. S. Levin and E. J. Huffman, Calculation of Positron Range and Its Effect on the Fundamental Limit of Positron Emission Tomography System Spatial Resolution, Phys. Med. Biol. 44, pp. 781-799, 1999
    • (1999) Phys. Med. Biol , vol.44 , pp. 781-799
    • Levin, C.S.1    Huffman, E.J.2
  • 2
    • 3242789549 scopus 로고    scopus 로고
    • Optimization and performance evaluation of the microPET II scanner for in vivo small-animal imaging
    • Y. Yang, Y. C. Tai, S. Siegel, D. F. Newport, B. Bai, Q. Li, R. M. Leahy and S. R. Cherry, Optimization and performance evaluation of the microPET II scanner for in vivo small-animal imaging, Phys. Med. Biol. 49(12), pp. 2527-2545, 2004
    • (2004) Phys. Med. Biol , vol.49 , Issue.12 , pp. 2527-2545
    • Yang, Y.1    Tai, Y.C.2    Siegel, S.3    Newport, D.F.4    Bai, B.5    Li, Q.6    Leahy, R.M.7    Cherry, S.R.8
  • 3
    • 17844363989 scopus 로고    scopus 로고
    • Performance Evaluation of the microPET Focus: A Third-Generation microPET Scanner Dedicated to Animal Imaging
    • Y. C. Tai, A. Ruangma, D. Rowland, S. Siegel, D. F. Newport, P. L. Chow and R. Laforest, Performance Evaluation of the microPET Focus: A Third-Generation microPET Scanner Dedicated to Animal Imaging, J. Nucl. Med. 46(3), pp. 455-463, 2005
    • (2005) J. Nucl. Med , vol.46 , Issue.3 , pp. 455-463
    • Tai, Y.C.1    Ruangma, A.2    Rowland, D.3    Siegel, S.4    Newport, D.F.5    Chow, P.L.6    Laforest, R.7
  • 4
    • 0036817371 scopus 로고    scopus 로고
    • MicroPET Imaging with Non-Conventional Isotopes
    • R. Laforest, D. J. Rowland and M. J. Welch, MicroPET Imaging with Non-Conventional Isotopes, IEEE Trans. Nucl. Sci. 49(5), pp. 2119-2126, 2002
    • (2002) IEEE Trans. Nucl. Sci , vol.49 , Issue.5 , pp. 2119-2126
    • Laforest, R.1    Rowland, D.J.2    Welch, M.J.3
  • 5
    • 84939036393 scopus 로고
    • Mathematical Removal of Positron Range Blurring in High Resolution Tomography
    • S. E. Derenzo, Mathematical Removal of Positron Range Blurring in High Resolution Tomography, IEEE Trans. Nucl. Sci. 33(1), pp. 565-569, 1986
    • (1986) IEEE Trans. Nucl. Sci , vol.33 , Issue.1 , pp. 565-569
    • Derenzo, S.E.1
  • 7
    • 0034178287 scopus 로고    scopus 로고
    • Resolution and noise properties of MAP reconstructions in fully 3D PET
    • J. Qi and R. M. Leahy, Resolution and noise properties of MAP reconstructions in fully 3D PET, IEEE Trans. Med. Imag. 19, pp. 493-506, 2000
    • (2000) IEEE Trans. Med. Imag , vol.19 , pp. 493-506
    • Qi, J.1    Leahy, R.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.