메뉴 건너뛰기




Volumn 3, Issue , 2005, Pages 1786-1789

A novel method for the estimation of infarct size in a reperfused rat model for pinhole SPECT

Author keywords

[No Author keywords available]

Indexed keywords

CARDIOVASCULAR SYSTEM; ESTIMATION; MATHEMATICAL MODELS; MEDICAL IMAGING; OPTICAL COLLIMATORS; SPURIOUS SIGNAL NOISE;

EID: 33846626305     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2005.1596667     Document Type: Conference Paper
Times cited : (3)

References (6)
  • 1
    • 0025542169 scopus 로고
    • Quantification of area at risk during coronary occlusion and degree of myocardial salvage after reperfusion with technetium-99m methoxyisobutyl isonitrile
    • AJ Sinusas, KA Trautman, JD Bergin, DD Watson, M Ruiz, WH Smith and GA Beller "Quantification of area at risk during coronary occlusion and degree of myocardial salvage after reperfusion with technetium-99m methoxyisobutyl isonitrile", Circulation 82:1424-37, 1990.
    • (1990) Circulation , vol.82 , pp. 1424-1437
    • Sinusas, A.J.1    Trautman, K.A.2    Bergin, J.D.3    Watson, D.D.4    Ruiz, M.5    Smith, W.H.6    Beller, G.A.7
  • 2
    • 0036306518 scopus 로고    scopus 로고
    • Z. Liu Z, G. A. Kastis, G. D. Stevenson, H. H. Barrett, L. R. Furenlid, M. A. Kupinski, D. D. Patton, D. W. Wilson, Quantitative Analysis of Acute Myocardial Infarct in Rat Hearts with Ischemia-Reperfusion Using a High-Resolution Stationary SPECT System, J. Nucl. Med. 43:933-939, 2002.
    • Z. Liu Z, G. A. Kastis, G. D. Stevenson, H. H. Barrett, L. R. Furenlid, M. A. Kupinski, D. D. Patton, D. W. Wilson, "Quantitative Analysis of Acute Myocardial Infarct in Rat Hearts with Ischemia-Reperfusion Using a High-Resolution Stationary SPECT System", J. Nucl. Med. 43:933-939, 2002.
  • 3
    • 0041626115 scopus 로고    scopus 로고
    • Pinhole Single-Photon Emission Computed Tomography for Myocardial Perfusion Imaging of Mice
    • M. C.Wu, D. W. Gao, R. E. Sievers, R. J. Lee, B. H. Hasegawa, M. W. Dae, "Pinhole Single-Photon Emission Computed Tomography for Myocardial Perfusion Imaging of Mice", J. Am. Coll. Card, 42:576-582, 2003.
    • (2003) J. Am. Coll. Card , vol.42 , pp. 576-582
    • Wu, M.C.1    Gao, D.W.2    Sievers, R.E.3    Lee, R.J.4    Hasegawa, B.H.5    Dae, M.W.6
  • 4
    • 33846639373 scopus 로고    scopus 로고
    • Quantitative imaging of myocardial infarct in rats with high resolution pinhole SPECT
    • in press
    • P. D. Acton, D. Thomas, R. Zhou, "Quantitative imaging of myocardial infarct in rats with high resolution pinhole SPECT", Int. J. Cardiovasc. Imaging, in press, 2005.
    • (2005) Int. J. Cardiovasc. Imaging
    • Acton, P.D.1    Thomas, D.2    Zhou, R.3
  • 5
    • 0036306518 scopus 로고    scopus 로고
    • W. P. Segars, B. M. W. Tsui, E. C. Frey, G. A. Johnson and S. S. Berr, Development of a 4D digital mouse phantom for molecular imaging research, Molecular Imaging & Biology, 6, Issue 3, p. 149-159, 2004.
    • W. P. Segars, B. M. W. Tsui, E. C. Frey, G. A. Johnson and S. S. Berr, "Development of a 4D digital mouse phantom for molecular imaging research", Molecular Imaging & Biology, Vol. 6, Issue 3, p. 149-159, 2004.
  • 6
    • 0000051658 scopus 로고    scopus 로고
    • Automated Region Selection for Analysis of Dynamic Cardiac SPECT Data
    • E.V.R. Di Bella, G.T. Gullberg, A.B. Barclay, and R.L. Eisner, "Automated Region Selection for Analysis of Dynamic Cardiac SPECT Data" IEEE Trans. Nucl. Sci . 44(3) 1355-1361, 1997.
    • (1997) IEEE Trans. Nucl. Sci , vol.44 , Issue.3 , pp. 1355-1361
    • Di Bella, E.V.R.1    Gullberg, G.T.2    Barclay, A.B.3    Eisner, R.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.