메뉴 건너뛰기




Volumn 4, Issue , 2005, Pages 2291-2295

Implementation of scatter corrected List-Mode OP-EM reconstruction algorithm and a dual (Histogram/List-Mode) reconstruction scheme for dynamic PET imaging

Author keywords

[No Author keywords available]

Indexed keywords

HIGH RESOLUTION RESEARCH TOMOGRAPHY (HRRT); ORDINARY POISSON LIST MODE EXPECTATION MAXIMIZATION (OP-LMEM); SINGLE SCATTER SIMULATION (SSS) TECHNIQUE; VARIANCE REDUCED DELAYED COINCIDENCE TECHNIQUE;

EID: 33846619321     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2005.1596792     Document Type: Conference Paper
Times cited : (5)

References (8)
  • 1
    • 4644340219 scopus 로고    scopus 로고
    • Statistical list-mode image reconstruction for the high resolution research tomography
    • A. Rahmim, M. Lenox, A. J. Reader, C. Michel. Z. Burbar, T. J. Ruth, and V. Sossi, "Statistical list-mode image reconstruction for the high resolution research tomography," Phys. Med. Biol., vol. 49, pp. 4239-4258, 2004.
    • (2004) Phys. Med. Biol , vol.49 , pp. 4239-4258
    • Rahmim, A.1    Lenox, M.2    Reader, A.J.3    Michel, C.4    Burbar, Z.5    Ruth, T.J.6    Sossi, V.7
  • 2
    • 26244444788 scopus 로고    scopus 로고
    • Statistical dynamic image reconstruction in state-of-the-art high resolution PET
    • A. Rahmim, J.-C. Cheng, S. Blinder, M-L Camborde, and V. Sossi, "Statistical dynamic image reconstruction in state-of-the-art high resolution PET," Phys. Med. Biol., vol. 50, pp. 4887-4912, 2005.
    • (2005) Phys. Med. Biol , vol.50 , pp. 4887-4912
    • Rahmim, A.1    Cheng, J.-C.2    Blinder, S.3    Camborde, M.-L.4    Sossi, V.5
  • 3
    • 0034244929 scopus 로고    scopus 로고
    • New, Faster, Image-Based Scatter Correction for 3D PET
    • C. C.Watson, "New, Faster, Image-Based Scatter Correction for 3D PET," IEEE Trans. Nucl. Sci., vol. 47, pp. 1587-1594, 2000.
    • (2000) IEEE Trans. Nucl. Sci , vol.47 , pp. 1587-1594
    • Watson, C.C.1
  • 4
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • H. M. Hudson and R. S. Larkin, "Accelerated image reconstruction using ordered subsets of projection data", IEEE Trans. Med. Imag., vol. 13, no. 4, pp. 601-609, 1994.
    • (1994) IEEE Trans. Med. Imag , vol.13 , Issue.4 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 5
    • 0022888626 scopus 로고
    • Quantitation in positron emission tomography: 7. A technique to reduce noise in accidental concidence measurements and coincidence efficinecy calibration
    • M. E. Casey and E. J. Hoffman, "Quantitation in positron emission tomography: 7. A technique to reduce noise in accidental concidence measurements and coincidence efficinecy calibration," J. Comput. Assist. Tomogr., vol. 10, no. 5, pp. 845-850, 1986.
    • (1986) J. Comput. Assist. Tomogr , vol.10 , Issue.5 , pp. 845-850
    • Casey, M.E.1    Hoffman, E.J.2
  • 7
    • 33846591506 scopus 로고    scopus 로고
    • to be published
    • L. Byars, C. Michel et al., to be published, 2005.
    • (2005)
    • Byars, L.1    Michel, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.