메뉴 건너뛰기




Volumn 5, Issue , 2005, Pages 3010-3013

SiliPET: Design of an ultra high resolution small animal PET scanner based on stacks of semiconductor detectors

Author keywords

Double sided silicon strip detector; Small animal PET

Indexed keywords

COMPUTER SIMULATION; GAMMA RAYS; LIGHT EMISSION; MEDICAL IMAGING; OPTICAL RESOLVING POWER; PHOTODETECTORS;

EID: 33846610646     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2005.1596964     Document Type: Conference Paper
Times cited : (6)

References (13)
  • 3
    • 0035554654 scopus 로고    scopus 로고
    • J. Seidel, J. J. Vaquero and M. V. Green. Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: comparison to simulated LSO scanners without depth-of-interaction capability. IEEE Nucl Sci Symp Conf Rec (2001) 3: 15551558
    • J. Seidel, J. J. Vaquero and M. V. Green. Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: comparison to simulated LSO scanners without depth-of-interaction capability. IEEE Nucl Sci Symp Conf Rec (2001) 3: 15551558
  • 6
    • 17644367489 scopus 로고    scopus 로고
    • Characterization and Readout of MADPET-II Detector Modules: Validation of a Unique Design Concept for High Resolution Small Animal PET
    • David P. McElroy, Wendelin Pimpl, Bernd J. Pichler, Magdalena Rafecas, Thomas Schler, and Sibylle I. Ziegler, "Characterization and Readout of MADPET-II Detector Modules: Validation of a Unique Design Concept for High Resolution Small Animal PET",IEEE Trans, on Nucl. Sci, VOL. 52, NO. 1, pp. 199-204
    • IEEE Trans, on Nucl. Sci , vol.52 , Issue.1 , pp. 199-204
    • McElroy, D.P.1    Pimpl, W.2    Pichler, B.J.3    Rafecas, M.4    Schler, T.5    Ziegler, S.I.6
  • 7
    • 0032316712 scopus 로고    scopus 로고
    • YAP-PET: First results of a small animal Positron Emissin Tomograph based on YAP:Ce finger crystals
    • Dec
    • A. Del Guerra, G. Di Domenico, M. Scandola, G. Zavattini, "YAP-PET: first results of a small animal Positron Emissin Tomograph based on YAP:Ce finger crystals", IEEE Trans. Nucl. Sci., vol. 45, no. 6, pp. 3105-3108, Dec. 1998.
    • (1998) IEEE Trans. Nucl. Sci , vol.45 , Issue.6 , pp. 3105-3108
    • Del Guerra, A.1    Di Domenico, G.2    Scandola, M.3    Zavattini, G.4
  • 10
    • 0036816252 scopus 로고    scopus 로고
    • Timing in Thick Silicon Detectors for a Compton Camera
    • M. Mikuz et al., "Timing in Thick Silicon Detectors for a Compton Camera" IEEE Trans. Nucl. Sci., vol. 49 (2002) pp. 2549-2557
    • (2002) IEEE Trans. Nucl. Sci , vol.49 , pp. 2549-2557
    • Mikuz, M.1
  • 11
    • 20144379657 scopus 로고    scopus 로고
    • G. Kanbach et al. Development and calibration of the tracking Compton/Pair telescope MEGA, NIM A541, (2005) pp. 310-322
    • G. Kanbach et al. "Development and calibration of the tracking Compton/Pair telescope MEGA", NIM A541, (2005) pp. 310-322
  • 12
    • 0142126804 scopus 로고    scopus 로고
    • P. Bloser et al. Development of silicon strip detectors for a medium energy gamma-ray telescope, NIM A512, (2003) pp. 220-228
    • P. Bloser et al. "Development of silicon strip detectors for a medium energy gamma-ray telescope", NIM A512, (2003) pp. 220-228
  • 13
    • 0028923795 scopus 로고
    • Positron emission tomography within a magnetic field using photomultiplier tubes and lightguides
    • N. L. Christensen et al. "Positron emission tomography within a magnetic field using photomultiplier tubes and lightguides", Phys. Med. Biol. 40 (1995) 691-497
    • (1995) Phys. Med. Biol , vol.40 , pp. 691-497
    • Christensen, N.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.