-
4
-
-
0037452439
-
Power consumption profile analysis and tensile strength measurements during moist agglomeration
-
Betz G., Bürgin P.J., and Leuenberger H. Power consumption profile analysis and tensile strength measurements during moist agglomeration. Int. J. Pharm. 252 (2003) 11-25
-
(2003)
Int. J. Pharm.
, vol.252
, pp. 11-25
-
-
Betz, G.1
Bürgin, P.J.2
Leuenberger, H.3
-
5
-
-
0026526343
-
Instrumentation of a high-shear mixer: evaluation and comparison of a new capacitive sensor, a watt meter, and a strain gage torque sensor for wet granulation monitoring
-
Corvari V., Fry W.C., Seibert W.L., and Augsburger L. Instrumentation of a high-shear mixer: evaluation and comparison of a new capacitive sensor, a watt meter, and a strain gage torque sensor for wet granulation monitoring. Pharm. Res. 9 (1992) 1525-1533
-
(1992)
Pharm. Res.
, vol.9
, pp. 1525-1533
-
-
Corvari, V.1
Fry, W.C.2
Seibert, W.L.3
Augsburger, L.4
-
6
-
-
33846602288
-
-
Daniher, D., Briens, L., Tallevi, A., in press. End-point detection in high-shear granulation using sound and vibration signal analysis. Powder Technol.
-
-
-
-
7
-
-
0031009324
-
Process control by application of near infra-red spectroscopy
-
Frake P., Greenhalgh D., Grierson S.M., Hempenstall J.M., and Rudd D.R. Process control by application of near infra-red spectroscopy. Int. J. Pharm. 151 (1977) 75-80
-
(1977)
Int. J. Pharm.
, vol.151
, pp. 75-80
-
-
Frake, P.1
Greenhalgh, D.2
Grierson, S.M.3
Hempenstall, J.M.4
Rudd, D.R.5
-
8
-
-
33845214203
-
-
Han, S.M., 1998. Direct moisture measurement during granulation using a near-infrared filter instrument. Pharmacopeial Forum, vol. 24. Available online at: http://www.ndcinfrared.com/applications/bulk_materials/bulkmaterials_articles/directmoisture/directmoisture.html.
-
-
-
-
10
-
-
0033384396
-
Granulation monitoring by fast Fourier transform technique
-
Ohike A., Ashihara K., and Ibuki R. Granulation monitoring by fast Fourier transform technique. Chem. Pharm. Bull. 47 (1999) 1734-1739
-
(1999)
Chem. Pharm. Bull.
, vol.47
, pp. 1734-1739
-
-
Ohike, A.1
Ashihara, K.2
Ibuki, R.3
-
11
-
-
0032531185
-
On-line monitoring of moisture content in an instrumented fluidized bed granulator with a multi-channel NIR moisture sensor
-
Rantanen J., Lehtola S., Rämet P., Mannermaa J.-P., and Yliruusi J. On-line monitoring of moisture content in an instrumented fluidized bed granulator with a multi-channel NIR moisture sensor. Powder Technol. 99 (1998) 163-170
-
(1998)
Powder Technol.
, vol.99
, pp. 163-170
-
-
Rantanen, J.1
Lehtola, S.2
Rämet, P.3
Mannermaa, J.-P.4
Yliruusi, J.5
-
12
-
-
0025100556
-
Analysis of end-point with power consumption in high speed mixer
-
Terashita K., Kato M., Ohike A., and Miyanami K. Analysis of end-point with power consumption in high speed mixer. Chem. Pharm. Bull. 38 (1990) 1977-1982
-
(1990)
Chem. Pharm. Bull.
, vol.38
, pp. 1977-1982
-
-
Terashita, K.1
Kato, M.2
Ohike, A.3
Miyanami, K.4
-
13
-
-
0025674396
-
Determination of end-point by frequency analysis of power consumption in agitation granulation
-
Terashita K., Watano S., and Miyanami K. Determination of end-point by frequency analysis of power consumption in agitation granulation. Chem. Pharm. Bull. 38 (1990) 3120-3123
-
(1990)
Chem. Pharm. Bull.
, vol.38
, pp. 3120-3123
-
-
Terashita, K.1
Watano, S.2
Miyanami, K.3
-
15
-
-
0035806248
-
Direct control of wet granulation processes by image processing system
-
Watano S. Direct control of wet granulation processes by image processing system. Powder Technol. 117 (2001) 163-172
-
(2001)
Powder Technol.
, vol.117
, pp. 163-172
-
-
Watano, S.1
-
16
-
-
0026501121
-
Frequency analysis of power consumption in agitation granulation of powder materials with sparingly soluble acetaminophen
-
Watano S., Terashita K., and Miyanami K. Frequency analysis of power consumption in agitation granulation of powder materials with sparingly soluble acetaminophen. Chem. Pharm. Bull. 40 (1992) 269-271
-
(1992)
Chem. Pharm. Bull.
, vol.40
, pp. 269-271
-
-
Watano, S.1
Terashita, K.2
Miyanami, K.3
-
17
-
-
0034665062
-
Application of acoustic emission to the monitoring and end point determination of a high shear granulation process
-
Whitaker M., Baker G.R., Westrup J., Goulding P.A., Rudd D.R., Belchamber R.M., and Collins M.P. Application of acoustic emission to the monitoring and end point determination of a high shear granulation process. Int. J. Pharm. 204 (2000) 79-91
-
(2000)
Int. J. Pharm.
, vol.204
, pp. 79-91
-
-
Whitaker, M.1
Baker, G.R.2
Westrup, J.3
Goulding, P.A.4
Rudd, D.R.5
Belchamber, R.M.6
Collins, M.P.7
|