메뉴 건너뛰기




Volumn 1, Issue , 2005, Pages 59-63

Prototype tracking studies for proton CT

Author keywords

[No Author keywords available]

Indexed keywords

ANGULAR RESOLUTION; MOST LIKELY PATH (MLP); PROTON COMPUTED TOMOGRAPHY; SILICON STRIP DETECTORS;

EID: 33846606275     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2005.1596207     Document Type: Conference Paper
Times cited : (3)

References (15)
  • 1
    • 0031807135 scopus 로고    scopus 로고
    • The precision of proton range calculations in proton radiotherapy treatment planning: Experimental verification of the relation between CT-HU and proton stopping power
    • B. Schaffner and E. Pedroni, "The precision of proton range calculations in proton radiotherapy treatment planning: experimental verification of the relation between CT-HU and proton stopping power", Phys Med Biol. 43(6): 1579-1592, 1998.
    • (1998) Phys Med Biol , vol.43 , Issue.6 , pp. 1579-1592
    • Schaffner, B.1    Pedroni, E.2
  • 5
    • 33846578482 scopus 로고    scopus 로고
    • L. R. Johnson, B. Keeney, G. Ross, H. K.-W. Sadrozinski, A. Seiden, D. C. Williams, L. Zhang,V. Bashkirov, R. W. Schulte, K. Shahnazi, Monte Carlo studies on proton computed tomography using a silicon strip detector telescope, SClPP 02/35.
    • L. R. Johnson, B. Keeney, G. Ross, H. K.-W. Sadrozinski, A. Seiden, D. C. Williams, L. Zhang,V. Bashkirov, R. W. Schulte, K. Shahnazi, "Monte Carlo studies on proton computed tomography using a silicon strip detector telescope", SClPP 02/35.
  • 6
    • 3442885471 scopus 로고    scopus 로고
    • The most likely path of an energetic charged particle through a uniform medium
    • D C Williams, "The most likely path of an energetic charged particle through a uniform medium", Phys. Med. Biol. 49 2899-2911, 2004.
    • (2004) Phys. Med. Biol , vol.49 , pp. 2899-2911
    • Williams, D.C.1
  • 9
    • 33846593643 scopus 로고    scopus 로고
    • First experimental calorimeter studies for proton CT at LLUMC
    • unpublished
    • M. C. Kloek, R. W. Schulte, V.Bashkirov. "First experimental calorimeter studies for proton CT at LLUMC", unpublished.
    • Kloek, M.C.1    Schulte, R.W.2    Bashkirov, V.3
  • 11
    • 5644226204 scopus 로고    scopus 로고
    • Reconstruction with most likely trajectory for proton computed tomography
    • T. Li, Z. Liang, et al. "Reconstruction with most likely trajectory for proton computed tomography". SPIE Medical Imaging, 2004.
    • (2004) SPIE Medical Imaging
    • Li, T.1    Liang, Z.2
  • 13
    • 34447297049 scopus 로고    scopus 로고
    • Review of Particle Physics
    • Particle Data Group
    • Particle Data Group, S. Eidelman et al., "Review of Particle Physics", Physics Letters B 592, 1 (2004).
    • (2004) Physics Letters B , vol.592 , pp. 1
    • Eidelman, S.1
  • 15
    • 33846620225 scopus 로고    scopus 로고
    • Detailed Monte Carlo Investigation of a Proton Computed Tomography System
    • Poster 103-25, Oct
    • G. A. P. Cirrone et al. "Detailed Monte Carlo Investigation of a Proton Computed Tomography System", Poster 103-25, 2005 IEEE NSS-MIC Symposium in Puerto Rico, Oct 2005.
    • (2005) 2005 IEEE NSS-MIC Symposium in Puerto Rico
    • Cirrone, G.A.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.