메뉴 건너뛰기




Volumn 42, Issue 10, 2006, Pages 3560-3562

A novel zero-drift detection method for highly sensitive GMR biochips

Author keywords

Biosensor; Micromagnetic simulation; Spin valve; Temperature drift cancellation

Indexed keywords

BIOSENSORS; MAGNETIC MATERIALS; MAGNETORESISTANCE; MODULATION; NANOSTRUCTURED MATERIALS;

EID: 33846602608     PISSN: 00189464     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMAG.2006.879615     Document Type: Article
Times cited : (18)

References (7)
  • 1
    • 31044447257 scopus 로고    scopus 로고
    • Spin valve sensors for ultrasensitive detection of super-paramagnetic nanoparticles for biological applications
    • G. Li et al., "Spin valve sensors for ultrasensitive detection of super-paramagnetic nanoparticles for biological applications," Sen. Actuators A, vol. 126, pp. 98-106, 2006.
    • (2006) Sen. Actuators A , vol.126 , pp. 98-106
    • Li, G.1
  • 2
    • 18544368501 scopus 로고    scopus 로고
    • Magnetic field-assisted DNA hybridization and simultaneous detection using micron-sized spin-valve sensors and magnetic nanoparticles
    • D. L. Graham et al., "Magnetic field-assisted DNA hybridization and simultaneous detection using micron-sized spin-valve sensors and magnetic nanoparticles," Sen. Actuators B, vol. 107, pp. 936-944, 2005.
    • (2005) Sen. Actuators B , vol.107 , pp. 936-944
    • Graham, D.L.1
  • 3
    • 0242364773 scopus 로고    scopus 로고
    • Design and performance of GMR sensors for the detection of magnetic microbeads in biosensors
    • J. C. Rife, M. M. Miller, P. E. Sheehan, C. R. Tamanaha, M. Tondra, and L. J. Whitman, "Design and performance of GMR sensors for the detection of magnetic microbeads in biosensors," Sen. Actuators A, vol. 107, pp. 209-218, 2003.
    • (2003) Sen. Actuators A , vol.107 , pp. 209-218
    • Rife, J.C.1    Miller, M.M.2    Sheehan, P.E.3    Tamanaha, C.R.4    Tondra, M.5    Whitman, L.J.6
  • 4
    • 0000595576 scopus 로고    scopus 로고
    • Sensor properties of a robust giant magnetoresistance material system at elevated temperatures
    • May
    • K.-M. H. Lenssen et al., "Sensor properties of a robust giant magnetoresistance material system at elevated temperatures," J. Appl. Phys., vol. 87, pp. 6665-6667, May 2000.
    • (2000) J. Appl. Phys , vol.87 , pp. 6665-6667
    • Lenssen, K.-M.H.1
  • 5
    • 33846569637 scopus 로고    scopus 로고
    • Magnetic sensor array having an analog frequency-division multiplexed output,
    • U.S. Patent Application 11/128105, May 11, filed
    • S.-J. Han and S. X. Wang, "Magnetic sensor array having an analog frequency-division multiplexed output," U.S. Patent Application 11/128105, May 11, 2005. (filed).
    • (2005)
    • Han, S.-J.1    Wang, S.X.2
  • 6
    • 0031189401 scopus 로고    scopus 로고
    • Magnetization rotation in spin-valve multilayers
    • Jul
    • M. Labrune, J. C. S. Kools, and A. Thiaville, "Magnetization rotation in spin-valve multilayers," J. Magn. Magn. Mater., vol. 171, pp. 1-15, Jul. 1997.
    • (1997) J. Magn. Magn. Mater , vol.171 , pp. 1-15
    • Labrune, M.1    Kools, J.C.S.2    Thiaville, A.3
  • 7
    • 33846619398 scopus 로고    scopus 로고
    • Design and Analysis of Magnetoresistive Recording Heads
    • E. M. Williams, Design and Analysis of Magnetoresistive Recording Heads. New York: Wiley, 2001, pp. 26-2.
    • (2001) New York: Wiley , pp. 26-22
    • Williams, E.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.