메뉴 건너뛰기




Volumn 3, Issue , 2005, Pages 1590-1595

Effect of randoms on signal-to-noise-ratio in TOF PET

Author keywords

[No Author keywords available]

Indexed keywords

RANDOM COINCIDENCE; RANDOM REDUCTION; TIME RESOLUTION; TIME-OF-FLIGHT (TOF);

EID: 33846600769     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2005.1596623     Document Type: Conference Paper
Times cited : (11)

References (17)
  • 1
    • 0026902676 scopus 로고
    • Cerium-doped lutetium orthosilicate: A fast, efficient new scintillator
    • C.L.Melcher and J.S.Schweitzer, "Cerium-doped lutetium orthosilicate: a fast, efficient new scintillator", IEEE Trans. Nucl. Sci., vol.39, pp. 502-505, 1992.
    • (1992) IEEE Trans. Nucl. Sci , vol.39 , pp. 502-505
    • Melcher, C.L.1    Schweitzer, J.S.2
  • 2
    • 0033337104 scopus 로고    scopus 로고
    • Prospects for time-of-flight PET using LSO scintillator
    • W.W. Moses and S.E. Derenzo, "Prospects for time-of-flight PET using LSO scintillator", IEEE Trans. Nucl. Sci., vol.46, no.3, pp. 783-788, 1999.
    • (1999) IEEE Trans. Nucl. Sci , vol.46 , Issue.3 , pp. 783-788
    • Moses, W.W.1    Derenzo, S.E.2
  • 3
    • 25444442095 scopus 로고    scopus 로고
    • First experimental results of time-of-flight reconstruction on an LSO PET scanner
    • M. Conti, B. Bendriem, M. Casey, M. Chen, F. Kehren, C. Michel, V. Panin, "First experimental results of time-of-flight reconstruction on an LSO PET scanner", Phys. Med. Biol., vol. 50 , pp. 4507-4526 , 2005.
    • (2005) Phys. Med. Biol , vol.50 , pp. 4507-4526
    • Conti, M.1    Bendriem, B.2    Casey, M.3    Chen, M.4    Kehren, F.5    Michel, C.6    Panin, V.7
  • 5
    • 0142126690 scopus 로고    scopus 로고
    • Time of flight in PET revisited
    • W.W. Moses, "Time of flight in PET revisited", IEEE Trans. Nucl. Sci., vol.50, no.5, pp. 1325-1330, 2003.
    • (2003) IEEE Trans. Nucl. Sci , vol.50 , Issue.5 , pp. 1325-1330
    • Moses, W.W.1
  • 6
    • 0020701632 scopus 로고
    • Time-of-flight positron emission tomography: Status relative to conventional PET
    • T.F. Budinger, "Time-of-flight positron emission tomography: status relative to conventional PET", J. Nucl. Medicine, vol. 24, pp. 73-78, 1983.
    • (1983) J. Nucl. Medicine , vol.24 , pp. 73-78
    • Budinger, T.F.1
  • 7
    • 0019572508 scopus 로고
    • A mathematical model for positron emission tomography systems having time-of-flight measurements
    • D.L. Snyder, L.J. Thomas, M.M. Ter-Pogossian, "A mathematical model for positron emission tomography systems having time-of-flight measurements", IEEE Trans. Nucl. Sci., vol. 28, no.3, pp. 3575-3583, 1981.
    • (1981) IEEE Trans. Nucl. Sci , vol.28 , Issue.3 , pp. 3575-3583
    • Snyder, D.L.1    Thomas, L.J.2    Ter-Pogossian, M.M.3
  • 9
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating count rates to image signal-to-noise ratios using noise equivalent counts
    • S.C. Strother, M.E. Casey and E.J. Hoffman, "Measuring PET scanner sensitivity: relating count rates to image signal-to-noise ratios using noise equivalent counts", IEEE Trans. Nucl. Sci., vol. 37, no.2, pp. 783-788, 1990.
    • (1990) IEEE Trans. Nucl. Sci , vol.37 , Issue.2 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 10
    • 0020206197 scopus 로고
    • Experimental assessment of the gain achieved by the utilization of time-of-flight information in a positron emission tomograph (Super PETT I)
    • M. Yamamoto, D.C. Ficke, M.M. Ter-Pogossian, "Experimental assessment of the gain achieved by the utilization of time-of-flight information in a positron emission tomograph (Super PETT I), IEEE Trans. Med. Imaging, vol.1, pp. 187-192, 1982.
    • (1982) IEEE Trans. Med. Imaging , vol.1 , pp. 187-192
    • Yamamoto, M.1    Ficke, D.C.2    Ter-Pogossian, M.M.3
  • 11
    • 0024611228 scopus 로고
    • An experimental evaluation of the effect of time-of-flight information in image reconstruction for the Scanditronix/PETT electronics SP-3000 positron emission tomograph -preliminary results
    • T.K.Lewellen, R.L. Harrison, A.N. Bice, "An experimental evaluation of the effect of time-of-flight information in image reconstruction for the Scanditronix/PETT electronics SP-3000 positron emission tomograph -preliminary results", IEEE Trans. Nucl. Sci., vol. 36, pp. 1095-1099, 1989.
    • (1989) IEEE Trans. Nucl. Sci , vol.36 , pp. 1095-1099
    • Lewellen, T.K.1    Harrison, R.L.2    Bice, A.N.3
  • 12
    • 0020703508 scopus 로고
    • Modeling of accidental coincidences in both conventional and time-of-flight positron-emission tomography
    • T.J. Holmes, D.C. Ficke, D.L. Snyder, "Modeling of accidental coincidences in both conventional and time-of-flight positron-emission tomography", IEEE Trans. Nucl. Sci., vol.31, no. 1, pp. 627-631, 1984.
    • (1984) IEEE Trans. Nucl. Sci , vol.31 , Issue.1 , pp. 627-631
    • Holmes, T.J.1    Ficke, D.C.2    Snyder, D.L.3
  • 13
    • 11844250590 scopus 로고    scopus 로고
    • Effect of random and scatter fractions in variance reduction using time-of-flight information
    • Portland, Oregon, USA, November 19-26
    • J.A. Kimdom, J.Qi, W.W. Moses, "Effect of random and scatter fractions in variance reduction using time-of-flight information", IEEE 2003 Nuclear Science Symposium Conference Record, Portland, Oregon, USA, November 19-26, 2003.
    • (2003) IEEE 2003 Nuclear Science Symposium Conference Record
    • Kimdom, J.A.1    Qi, J.2    Moses, W.W.3
  • 15
    • 33846637951 scopus 로고    scopus 로고
    • Extension of single scatter simulation to scatter correction of time-of-flight PET
    • San Juan, Puerto Rico, October 23-29
    • C.C. Watson, "Extension of single scatter simulation to scatter correction of time-of-flight PET", IEEE 2005 Nuclear Science Symposium Conference Record, San Juan, Puerto Rico, October 23-29, 2005.
    • (2005) IEEE 2005 Nuclear Science Symposium Conference Record
    • Watson, C.C.1
  • 16
    • 0019656680 scopus 로고
    • Image reconstruction and noise evaluation in photon time-of-flight assisted positron emission tomography
    • T. Tomitani, "Image reconstruction and noise evaluation in photon time-of-flight assisted positron emission tomography", IEEE Trans. Nucl. Sci., vol. 28, no. 6, pp. 4582-4588, 1981.
    • (1981) IEEE Trans. Nucl. Sci , vol.28 , Issue.6 , pp. 4582-4588
    • Tomitani, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.