메뉴 건너뛰기




Volumn 3, Issue , 2005, Pages 1658-1661

An integrated microfluidic blood sampler for determination of blood input function in quantitative mouse microPET studies

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD SAMPLER; DESIGNATED WELLS; MICROFLUIDIC PLATFORM; SAMPLING DEVICES;

EID: 33846575079     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2005.1596638     Document Type: Conference Paper
Times cited : (5)

References (10)
  • 2
    • 0029160881 scopus 로고
    • Factor analysis for extraction of blood time-activity curves in dynamic FDG-PET studies
    • H. M. Wu, C. K. Hoh, Y. Choi, H. R. Schelbert, R. A. Hawkins, M. E. Phelps, and S. C. Huang, "Factor analysis for extraction of blood time-activity curves in dynamic FDG-PET studies," J Nucl Med, vol. 36, pp. 1714-22, 1995.
    • (1995) J Nucl Med , vol.36 , pp. 1714-1722
    • Wu, H.M.1    Hoh, C.K.2    Choi, Y.3    Schelbert, H.R.4    Hawkins, R.A.5    Phelps, M.E.6    Huang, S.C.7
  • 4
    • 33846627403 scopus 로고    scopus 로고
    • H. M. Wu, M. C. Kreissl, M. Jodan, M. Prins, W. Ladno, H. R. Schelbert, M. E. Phelps, and S. C. Huang, Estimation of left ventricular size of mouse heart using cluster analysis and high temporal resolution micrPET images to account for partial effect (PVE) in the derivation of input functions, JNuc Med, 46, pp. 204p, 2005.
    • H. M. Wu, M. C. Kreissl, M. Jodan, M. Prins, W. Ladno, H. R. Schelbert, M. E. Phelps, and S. C. Huang, "Estimation of left ventricular size of mouse heart using cluster analysis and high temporal resolution micrPET images to account for partial volume effect (PVE) in the derivation of input functions," JNuc Med, vol. 46, pp. 204p, 2005.
  • 5
    • 33846632910 scopus 로고    scopus 로고
    • Mouse Plasma And Whole Blood Difference In 2-[18f]Fluoro-2-Deoxy-D-Glucose (FDG) Concentration: Implication For Quantitative Mouse FDG-PET Studies
    • H. M. Wu, W. Ladno, D. Truong, M. C. Kreissl, M. Prins, H. R. Schelbert, M. E. Phelps, and S. C. Huang, "Mouse Plasma And Whole Blood Difference In 2-[18f]Fluoro-2-Deoxy-D-Glucose (FDG) Concentration: Implication For Quantitative Mouse FDG-PET Studies," JNuc Med, vol. 46, pp. 204p, 2005.
    • (2005) JNuc Med , vol.46
    • Wu, H.M.1    Ladno, W.2    Truong, D.3    Kreissl, M.C.4    Prins, M.5    Schelbert, H.R.6    Phelps, M.E.7    Huang, S.C.8
  • 6
    • 22844452107 scopus 로고    scopus 로고
    • P. L. Chow, F. R. Rannou, and A. F. Chatziioannou, Attenuation correction for small animal PET tomographs, Physics in Medicine and Biology, Physics in Medicine and Biology, 50, pp. 1837-1850, 2005.
    • P. L. Chow, F. R. Rannou, and A. F. Chatziioannou, "Attenuation correction for small animal PET tomographs," Physics in Medicine and Biology," Physics in Medicine and Biology, vol. 50, pp. 1837-1850, 2005.
  • 7
    • 0018582265 scopus 로고
    • Tomographic measurement of local cerebral glucose metabolic rate in humans with (F-18)2-fluoro-2-deoxy-D-glucose: Validation of method
    • M. E. Phelps, S. C. Huang, E. J. Hoffman, C. Selin, L. Sokoloff, and D. E. Kuhl, "Tomographic measurement of local cerebral glucose metabolic rate in humans with (F-18)2-fluoro-2-deoxy-D-glucose: validation of method," Annals of Neurology, vol. 6, pp. 371-88, 1979.
    • (1979) Annals of Neurology , vol.6 , pp. 371-388
    • Phelps, M.E.1    Huang, S.C.2    Hoffman, E.J.3    Selin, C.4    Sokoloff, L.5    Kuhl, D.E.6
  • 9
    • 0020321344 scopus 로고
    • Calculation of cerebral glucose phosphorylation from brain uptake of glucose analogs in vivo: A re-examination
    • A. Gjedde, "Calculation of cerebral glucose phosphorylation from brain uptake of glucose analogs in vivo: a re-examination," Brain Res, vol. 257, pp. 237-74, 1982.
    • (1982) Brain Res , vol.257 , pp. 237-274
    • Gjedde, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.