메뉴 건너뛰기




Volumn 6, Issue 1, 2007, Pages 34-37

American Brachytherapy Society recommends no change for prostate permanent implant dose prescriptions using iodine-125 or palladium-103

Author keywords

103Pd; 125I; ABS guidelines; Dosimetry; Prescription; Prostate brachytherapy

Indexed keywords

IODINE 125; PALLADIUM 103;

EID: 33846566218     PISSN: 15384721     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.brachy.2006.11.001     Document Type: Article
Times cited : (45)

References (22)
  • 1
    • 0033047030 scopus 로고    scopus 로고
    • American Brachytherapy Society (ABS) recommendations for transperineal permanent brachytherapy of prostate cancer
    • Nag S., Beyer D., Friedland J., et al. American Brachytherapy Society (ABS) recommendations for transperineal permanent brachytherapy of prostate cancer. Int J Radiat Oncol Biol Phys 44 (1999) 789-799
    • (1999) Int J Radiat Oncol Biol Phys , vol.44 , pp. 789-799
    • Nag, S.1    Beyer, D.2    Friedland, J.3
  • 3
    • 1142304255 scopus 로고    scopus 로고
    • Update of AAPM task group No. 43 report: A revised AAPM protocol for brachytherapy dose calculations
    • Rivard M.J., Coursey B.M., DeWerd L.A., et al. Update of AAPM task group No. 43 report: A revised AAPM protocol for brachytherapy dose calculations. Med Phys 31 (2004) 633-674
    • (2004) Med Phys , vol.31 , pp. 633-674
    • Rivard, M.J.1    Coursey, B.M.2    DeWerd, L.A.3
  • 5
    • 0034004512 scopus 로고    scopus 로고
    • 103Pd interstitial source calibration and dosimetry: Implications for dose specification and prescription (AAPM Report No. 69)
    • 103Pd interstitial source calibration and dosimetry: Implications for dose specification and prescription (AAPM Report No. 69). Med Phys 27 (2000) 634-642
    • (2000) Med Phys , vol.27 , pp. 634-642
    • Williamson, J.F.1    Coursey, B.M.2    DeWerd, L.A.3
  • 6
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • Nath R., Anderson L.L., Luxton G., et al. Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. Med Phys 22 (1995) 209-234
    • (1995) Med Phys , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3
  • 7
    • 0032891406 scopus 로고    scopus 로고
    • Guidance to users of Nycomed Amersham and North American Scientific, Inc. I-125 Interstitial Sources: Dosimetry and calibration changes: Recommendation of the American Association of Physicists in Medicine Radiation Therapy Committee Ad Hoc Subcommittee on Low-Energy Seed Dosimetry
    • Williamson J.F., Coursey B.M., DeWerd L.A., et al. Guidance to users of Nycomed Amersham and North American Scientific, Inc. I-125 Interstitial Sources: Dosimetry and calibration changes: Recommendation of the American Association of Physicists in Medicine Radiation Therapy Committee Ad Hoc Subcommittee on Low-Energy Seed Dosimetry. Med Phys 26 (1999) 570-573
    • (1999) Med Phys , vol.26 , pp. 570-573
    • Williamson, J.F.1    Coursey, B.M.2    DeWerd, L.A.3
  • 9
    • 0034004556 scopus 로고    scopus 로고
    • 103Pd seeds with air kerma strength calibration based upon a primary national standard
    • 103Pd seeds with air kerma strength calibration based upon a primary national standard. Med Phys 27 (2000) 655-658
    • (2000) Med Phys , vol.27 , pp. 655-658
    • Nath, R.1    Yue, N.2    Shahnazi, K.3    Bongiorni, P.4
  • 10
    • 0242495806 scopus 로고    scopus 로고
    • Minimizing prostate brachytherapy-related morbidity
    • Merrick G.S., Wallner K.E., and Butler W.M. Minimizing prostate brachytherapy-related morbidity. Urology 62 (2003) 786-792
    • (2003) Urology , vol.62 , pp. 786-792
    • Merrick, G.S.1    Wallner, K.E.2    Butler, W.M.3
  • 11
    • 0035176374 scopus 로고    scopus 로고
    • Penile erectile function after permanent radioactive seed implantation for treatment of prostate cancer
    • Stock R.G., Kao J., and Stone N.N. Penile erectile function after permanent radioactive seed implantation for treatment of prostate cancer. J Urol 165 (2001) 436-439
    • (2001) J Urol , vol.165 , pp. 436-439
    • Stock, R.G.1    Kao, J.2    Stone, N.N.3
  • 12
    • 0029008161 scopus 로고
    • Dosimetry guidelines to minimize urethral and rectal morbidity following transperineal I-125 prostate brachytherapy
    • Wallner K., Roy J., and Harrison L. Dosimetry guidelines to minimize urethral and rectal morbidity following transperineal I-125 prostate brachytherapy. Int J Radiat Oncol Biol Phys 32 (1995) 465-471
    • (1995) Int J Radiat Oncol Biol Phys , vol.32 , pp. 465-471
    • Wallner, K.1    Roy, J.2    Harrison, L.3
  • 13
    • 28844494984 scopus 로고    scopus 로고
    • Variability of prostate preimplant dosimetry: A multi-institutional analysis
    • Merrick G.S., Butler W.M., Waller K.E., et al. Variability of prostate preimplant dosimetry: A multi-institutional analysis. Brachytherapy 4 (2005) 241-251
    • (2005) Brachytherapy , vol.4 , pp. 241-251
    • Merrick, G.S.1    Butler, W.M.2    Waller, K.E.3
  • 14
    • 13744261123 scopus 로고    scopus 로고
    • 125Iodine brachytherapy of prostate cancer
    • 125Iodine brachytherapy of prostate cancer. J Urol 173 (2005) 803-807
    • (2005) J Urol , vol.173 , pp. 803-807
    • Stone, N.N.1    Stock, R.G.2    Unger, P.3
  • 15
    • 0035400236 scopus 로고    scopus 로고
    • A comprehensive review of CT-based dosimetry parameters and biochemical control in patients treated with permanent prostate brachytherapy
    • Potters L., Cao Y., Calugaru E., et al. A comprehensive review of CT-based dosimetry parameters and biochemical control in patients treated with permanent prostate brachytherapy. Int J Radiat Oncol Biol Phys 50 (2001) 605-614
    • (2001) Int J Radiat Oncol Biol Phys , vol.50 , pp. 605-614
    • Potters, L.1    Cao, Y.2    Calugaru, E.3
  • 16
    • 0344395011 scopus 로고    scopus 로고
    • 103Pd for low-risk prostate cancer: Preliminary PSA outcomes from a prospective randomized multicenter trial
    • 103Pd for low-risk prostate cancer: Preliminary PSA outcomes from a prospective randomized multicenter trial. Int J Radiat Oncol Biol Phys 57 (2003) 1297-1303
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1297-1303
    • Wallner, K.1    Merrick, G.2    True, L.3
  • 18
    • 17144368838 scopus 로고    scopus 로고
    • 12-year outcomes following permanent prostate brachytherapy in patients with clinically localized prostate cancer
    • Potters L., Morgenstern, Calugaru E., et al. 12-year outcomes following permanent prostate brachytherapy in patients with clinically localized prostate cancer. J Urol 173 (2005) 1562-1566
    • (2005) J Urol , vol.173 , pp. 1562-1566
    • Potters, L.1    Morgenstern2    Calugaru, E.3
  • 19
    • 14344256744 scopus 로고    scopus 로고
    • 103Pd brachytherapy versus radical prostatectomy in patients with clinically localized prostate cancer: A 12-year experience from a single group practice
    • 103Pd brachytherapy versus radical prostatectomy in patients with clinically localized prostate cancer: A 12-year experience from a single group practice. Brachytherapy 4 (2005) 34-44
    • (2005) Brachytherapy , vol.4 , pp. 34-44
    • Sharkey, J.1    Cantor, A.2    Solc, Z.3
  • 20
    • 0037441806 scopus 로고    scopus 로고
    • Long-term outcomes after treatment with external beam radiation therapy and palladium 103 for patients with higher risk prostate carcinoma: Influence of prostatic acid phosphatase
    • Dattoli M., Wallner K., True L., et al. Long-term outcomes after treatment with external beam radiation therapy and palladium 103 for patients with higher risk prostate carcinoma: Influence of prostatic acid phosphatase. Cancer 97 (2003) 979-983
    • (2003) Cancer , vol.97 , pp. 979-983
    • Dattoli, M.1    Wallner, K.2    True, L.3
  • 21
    • 0030801752 scopus 로고    scopus 로고
    • Code of practice for brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 56
    • Nath R., Anderson L.L., Meli J.A., et al. Code of practice for brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 56. Med Phys 24 (1997) 1557-1598
    • (1997) Med Phys , vol.24 , pp. 1557-1598
    • Nath, R.1    Anderson, L.L.2    Meli, J.A.3
  • 22
    • 33645530573 scopus 로고    scopus 로고
    • 60Co therapy level beams, and the transfer to the AAPM accredited dosimetry calibration laboratories
    • 60Co therapy level beams, and the transfer to the AAPM accredited dosimetry calibration laboratories. Med Phys 33 (2006) 1074-1077
    • (2006) Med Phys , vol.33 , pp. 1074-1077
    • Minniti, R.1    Chen-Mayer, H.2    Seltzer, S.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.