Volumn 3, Issue , 2005, Pages 1809-1813

Extravascular density model for PET partial volume correction

Author keywords

[No Author keywords available]

Indexed keywords

ENDOCARDIAL PLACEMENT; EXTRAVASCULAR DENSITY MODELS (EV); PARTIAL VOLUME LOSSES (PV); TRANSMISSION RESOLUTION;

EID: 33846560986     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2005.1596672     Document Type: Conference Paper
Times cited : (3)

References (15)
  • 3
    • 33645208753 scopus 로고    scopus 로고
    • Perfusable Tissue Index Obtained Positron Emission Tomography as a Marker of Myocardial Viability in Patients With Ischemic Ventricular Dysfunction
    • H. Itoh, M. Namura, H. Seki, T. Asai, T. Tsuchiya, H. Uenishi, et. al., "Perfusable Tissue Index Obtained Positron Emission Tomography as a Marker of Myocardial Viability in Patients With Ischemic Ventricular Dysfunction," Circ, vol. 66, pp. 3411-344, 2002
    • (2002) Circ , vol.66 , pp. 3411-3344
    • Itoh, H.1    Namura, M.2    Seki, H.3    Asai, T.4    Tsuchiya, T.5    Uenishi, H.6    et., al.7
  • 5
    • 0025938248 scopus 로고
    • Physical Aspects of Cardiac Scanning with a Block Detector Positron Tomograph
    • T. Spinks, L. Araujo, C. Rhodes, B. Hutton, "Physical Aspects of Cardiac Scanning with a Block Detector Positron Tomograph," J of Comput Assist Tomogr, vol. 15, no. 5, pp. 893-904, 1991
    • (1991) J of Comput Assist Tomogr , vol.15 , Issue.5 , pp. 893-904
    • Spinks, T.1    Araujo, L.2    Rhodes, C.3    Hutton, B.4
  • 7
    • 33846649861 scopus 로고    scopus 로고
    • R.W. Wassenaar, R.S.B. Beanlands, T.D. Ruddy, R.A. deKemp, Resolution Recovery with 3D PET Extravascular Density Imaging, Opto-Canada; SPIE Regional Meeting on Optoelectronics, Photonics, and Imaging; TD01, pp. 386-89, 2002
    • R.W. Wassenaar, R.S.B. Beanlands, T.D. Ruddy, R.A. deKemp, "Resolution Recovery with 3D PET Extravascular Density Imaging," Opto-Canada; SPIE Regional Meeting on Optoelectronics, Photonics, and Imaging; vol. TD01, pp. 386-89, 2002
  • 8
    • 0019780254 scopus 로고
    • Quantitative Measurement of Regional Extravascular Lung Density Using Positron Emission and Transmission Tomography
    • C.G. Rhodes, P. Wollmer, F. Faxio, T. Jones, "Quantitative Measurement of Regional Extravascular Lung Density Using Positron Emission and Transmission Tomography," J Comput Assist Tomogr, vol. 5, no. 6, pp. 783-791, 1981
    • (1981) J Comput Assist Tomogr , vol.5 , Issue.6 , pp. 783-791
    • Rhodes, C.G.1    Wollmer, P.2    Faxio, F.3    Jones, T.4
  • 10
    • 0026710876 scopus 로고
    • A Region of Interest Strategy for Minimizing Resolution Distortions in Quantitative Myocardial PET Studies
    • G.D. Hutchins, J.M. Caraher, R.R. Raylman, "A Region of Interest Strategy for Minimizing Resolution Distortions in Quantitative Myocardial PET Studies," J Nuc Med, vol. 33, pp. 1243-1250, 1992
    • (1992) J Nuc Med , vol.33 , pp. 1243-1250
    • Hutchins, G.D.1    Caraher, J.M.2    Raylman, R.R.3
  • 12
    • 33645652860 scopus 로고    scopus 로고
    • A Canine Model of 3D PET Extravascular Density Imaging for Regional Myocardial Resolution Recovery
    • R. Wassenaar, S. Mason, A DiNardo, D. Gauthier, J. DaSilva, R. Beanlands, R. deKemp, "A Canine Model of 3D PET Extravascular Density Imaging for Regional Myocardial Resolution Recovery," J Nuc Med, vol. 46, no. 2, pp. 1522P, 2005
    • (2005) J Nuc Med , vol.46 , Issue.2
    • Wassenaar, R.1    Mason, S.2    DiNardo, A.3    Gauthier, D.4    DaSilva, J.5    Beanlands, R.6    deKemp, R.7
  • 13
    • 0027530709 scopus 로고
    • Automated Region Definition for Cardiac Nitrogen-13-Ammonia PET Imaging
    • O. Muzik, R. Beanlands, E. Wolfe, G.D. Hutchins, M. Schwaiger, "Automated Region Definition for Cardiac Nitrogen-13-Ammonia PET Imaging," J Nuc Med, vol. 34, pp.2336-2344, 1993
    • (1993) J Nuc Med , vol.34 , pp. 2336-2344
    • Muzik, O.1    Beanlands, R.2    Wolfe, E.3    Hutchins, G.D.4    Schwaiger, M.5
  • 15
    • 85037542073 scopus 로고    scopus 로고
    • R. Hart, T.D. Ruddy, R.S. Beanlands, R.A. deKemp, Sinusoidal Eccentric Thickening Model for ECG-Gated SPECT Perfusion Imaging, Opto-Canada: SPIE Regional Meeting on Optoelectronics, Photonics, and Imaging, TD01, pp. 370-372, 2002
    • R. Hart, T.D. Ruddy, R.S. Beanlands, R.A. deKemp, "Sinusoidal Eccentric Thickening Model for ECG-Gated SPECT Perfusion Imaging," Opto-Canada: SPIE Regional Meeting on Optoelectronics, Photonics, and Imaging, vol. TD01, pp. 370-372, 2002


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.