메뉴 건너뛰기




Volumn 25, Issue 2, 2007, Pages 278-292

Sequential anisotropic Wiener filtering applied to 3D MRI data

Author keywords

Anisotropic filter; MMSE criterion; MSE performance; Orientation filter; Parameter estimation; Sequential filter; Wiener filter

Indexed keywords

ANISOTROPIC FILTER; ARTICLE; FILTER; FILTRATION; NEUROIMAGING; NUCLEAR MAGNETIC RESONANCE IMAGING; ORIENTATION FILTER; PARAMETER; PRIORITY JOURNAL; SEQUENTIAL FILTER; THREE DIMENSIONAL IMAGING; WIENER FILTER;

EID: 33846557373     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2006.05.001     Document Type: Article
Times cited : (49)

References (33)
  • 2
    • 51249193175 scopus 로고
    • Generalized harmonic analysis
    • Wiener N. Generalized harmonic analysis. Acta Math 55 (1930) 117-258
    • (1930) Acta Math , vol.55 , pp. 117-258
    • Wiener, N.1
  • 6
    • 0018998148 scopus 로고
    • Digital image enhancement and noise filtering using local statistics
    • Lee J. Digital image enhancement and noise filtering using local statistics. IEEE Trans Pattern Anal Mach Intell 2 (1980) 165-168
    • (1980) IEEE Trans Pattern Anal Mach Intell , vol.2 , pp. 165-168
    • Lee, J.1
  • 9
    • 27244447833 scopus 로고    scopus 로고
    • Kriging filters for multidimensional signal processing
    • Ruiz-Alzola J., Alberola-Lopez C., and Westin C.F. Kriging filters for multidimensional signal processing. Signal Process 85 (2005) 413-439
    • (2005) Signal Process , vol.85 , pp. 413-439
    • Ruiz-Alzola, J.1    Alberola-Lopez, C.2    Westin, C.F.3
  • 11
    • 0033322132 scopus 로고    scopus 로고
    • Wavelet-based Rician noise removal for magnetic resonance imaging
    • Nowak R.D. Wavelet-based Rician noise removal for magnetic resonance imaging. IEEE Trans Image Process 8 (1999) 1408-1419
    • (1999) IEEE Trans Image Process , vol.8 , pp. 1408-1419
    • Nowak, R.D.1
  • 12
    • 0033062659 scopus 로고    scopus 로고
    • Wavelet packet denoising of magnetic resonance images: importance of Rician noise at low SNR
    • Wood J.C., and Johnson K.M. Wavelet packet denoising of magnetic resonance images: importance of Rician noise at low SNR. Magn Reson Med 41 (1999) 631-635
    • (1999) Magn Reson Med , vol.41 , pp. 631-635
    • Wood, J.C.1    Johnson, K.M.2
  • 18
    • 0032784869 scopus 로고    scopus 로고
    • Adaptive nonlocal filtering: a fast alternative to anisotropic diffusion for image enhancement
    • Fischl B., and Schwartz E.L. Adaptive nonlocal filtering: a fast alternative to anisotropic diffusion for image enhancement. IEEE Trans Pattern Anal Mach Intell 21 (1999) 42-48
    • (1999) IEEE Trans Pattern Anal Mach Intell , vol.21 , pp. 42-48
    • Fischl, B.1    Schwartz, E.L.2
  • 19
    • 0031182197 scopus 로고    scopus 로고
    • An adaptive image enhancement algorithm
    • Silva-Centeno J.A., and Haertel V. An adaptive image enhancement algorithm. Pattern Recogn 30 (1997) 1183-1189
    • (1997) Pattern Recogn , vol.30 , pp. 1183-1189
    • Silva-Centeno, J.A.1    Haertel, V.2
  • 21
    • 0344358958 scopus 로고
    • Scale space and edge detection using anisotropic filtering of MRI data
    • Perona P., and Malik J. Scale space and edge detection using anisotropic filtering of MRI data. IEEE Trans Med Imaging 11 (1992) 221-232
    • (1992) IEEE Trans Med Imaging , vol.11 , pp. 221-232
    • Perona, P.1    Malik, J.2
  • 22
    • 0036879769 scopus 로고    scopus 로고
    • Flux-based anisotropic diffusion applied to enhancement of 3D angiograms
    • Krissian K. Flux-based anisotropic diffusion applied to enhancement of 3D angiograms. IEEE Trans Med Imaging 21 (2002) 1440-1442
    • (2002) IEEE Trans Med Imaging , vol.21 , pp. 1440-1442
    • Krissian, K.1
  • 23
    • 33747645569 scopus 로고    scopus 로고
    • On the estimation of the coefficient of variation for anisotropic diffusion speckle filtering
    • Aja S., and Alberola-Lopez C. On the estimation of the coefficient of variation for anisotropic diffusion speckle filtering. IEEE Trans Image Process 15 (2006) 2694-2701
    • (2006) IEEE Trans Image Process , vol.15 , pp. 2694-2701
    • Aja, S.1    Alberola-Lopez, C.2
  • 24
    • 0026203860 scopus 로고
    • Iterative Wiener filters for image restoration
    • Hillery A.D., and Chin R.T. Iterative Wiener filters for image restoration. IEEE Trans Signal Process 39 (1991) 1892-1899
    • (1991) IEEE Trans Signal Process , vol.39 , pp. 1892-1899
    • Hillery, A.D.1    Chin, R.T.2
  • 25
    • 84975534691 scopus 로고
    • Restoration of images distorted by systems of random impulse response
    • Ward R.K., and Saleh B.E.A. Restoration of images distorted by systems of random impulse response. J Opt Soc Am 2 (1985) 1254-1259
    • (1985) J Opt Soc Am , vol.2 , pp. 1254-1259
    • Ward, R.K.1    Saleh, B.E.A.2
  • 26
    • 0000913755 scopus 로고
    • Spatial interaction and the statistical analysis of lattice systems (with discussion)
    • Besag J. Spatial interaction and the statistical analysis of lattice systems (with discussion). J Royal Statist Soc Ser B 36 (1974) 192-236
    • (1974) J Royal Statist Soc Ser B , vol.36 , pp. 192-236
    • Besag, J.1
  • 27
    • 0028839871 scopus 로고
    • The Rician distribution of noisy MRI data
    • Gudbjartsson H., and Patz S. The Rician distribution of noisy MRI data. Magn Reson Med 34 (1995) 910-914
    • (1995) Magn Reson Med , vol.34 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 28
    • 0033000058 scopus 로고    scopus 로고
    • Parameter estimation from Rician-distributed data sets using a maximum likelihood estimator: application to T1 and perfusion measurements
    • Karlsen O.T., Verhagen R., and Bove W.M.M.J. Parameter estimation from Rician-distributed data sets using a maximum likelihood estimator: application to T1 and perfusion measurements. Magn Reson Med 41 (1999) 614-623
    • (1999) Magn Reson Med , vol.41 , pp. 614-623
    • Karlsen, O.T.1    Verhagen, R.2    Bove, W.M.M.J.3
  • 29
    • 1542346904 scopus 로고    scopus 로고
    • Maximum likelihood estimation of signal amplitude and noise variance from MR data
    • Sijbers J., and den Dekker A.J. Maximum likelihood estimation of signal amplitude and noise variance from MR data. Magn Reson Med 51 (2004) 586-594
    • (2004) Magn Reson Med , vol.51 , pp. 586-594
    • Sijbers, J.1    den Dekker, A.J.2
  • 30
    • 0024438651 scopus 로고
    • Measuring signal-to-noise ratios in MR-imaging
    • Kausmann L., Kramer D., Crooks L., and Ortendahl D. Measuring signal-to-noise ratios in MR-imaging. Radiology 173 (1989) 265-267
    • (1989) Radiology , vol.173 , pp. 265-267
    • Kausmann, L.1    Kramer, D.2    Crooks, L.3    Ortendahl, D.4
  • 31
    • 20344396104 scopus 로고    scopus 로고
    • 3D Bayesian regularization of diffusion tensor MRI using multivariate gaussian Markov random fields
    • Martin-Fernandez M., Westin C.-F., and Alberola-Lopez C. 3D Bayesian regularization of diffusion tensor MRI using multivariate gaussian Markov random fields. Lect Notes Comput Sci 3216 (2004) 351-359
    • (2004) Lect Notes Comput Sci , vol.3216 , pp. 351-359
    • Martin-Fernandez, M.1    Westin, C.-F.2    Alberola-Lopez, C.3
  • 33
    • 0033233097 scopus 로고    scopus 로고
    • MRI simulation-based evaluation of image-processing and classification methods
    • Kwan R.K.S., Evans A.C., and Pike G.B. MRI simulation-based evaluation of image-processing and classification methods. IEEE Trans Med Imaging 18 (1999) 1085-1097
    • (1999) IEEE Trans Med Imaging , vol.18 , pp. 1085-1097
    • Kwan, R.K.S.1    Evans, A.C.2    Pike, G.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.