메뉴 건너뛰기




Volumn 29, Issue 4, 2006, Pages 321-327

Measurement of magnetic fields produced by a "Magnetic deflector" for the removal of electron contamination in radiotherapy

Author keywords

Electron contamination; Magnetic fields; Nd2Fe14B magnets; Skin dose; Surface dose

Indexed keywords

MAGNETIC FIELD EFFECTS; MAGNETIC FIELD MEASUREMENT; SKIN; X RAYS;

EID: 33846527416     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03178398     Document Type: Article
Times cited : (9)

References (14)
  • 1
    • 0029899797 scopus 로고    scopus 로고
    • Magnetic repulsion of linear accelerator contaminates
    • Butson, M. J, Wong, T. Y, et al., Magnetic repulsion of linear accelerator contaminates, Med. Phys. 23 (6), 953-955, 1996.
    • (1996) Med. Phys. , vol.23 , Issue.6 , pp. 953-955
    • Butson, M.J.1    Wong, T.Y.2
  • 2
    • 0031150166 scopus 로고    scopus 로고
    • Skin Dose Reduction by a Clinically Viable Magnetic Deflector
    • Butson, M. J., Yu, P, et al., Skin Dose Reduction by a Clinically Viable Magnetic Deflector, Australian. Phys. Eng. Sci. Med. 20 (2), 107-110, 1997.
    • (1997) Australian. Phys. Eng. Sci. Med. , vol.20 , Issue.2 , pp. 107-110
    • Butson, M.J.1    Yu, P.2
  • 3
    • 0022578185 scopus 로고
    • Build-up/surface dose and exit dose measurements for a 6-MV linear accelerator
    • Purdy, J. A., Build-up/surface dose and exit dose measurements for a 6-MV linear accelerator, Med. Phys. 13 (2), 259-262, 1986.
    • (1986) Med. Phys. , vol.13 , Issue.2 , pp. 259-262
    • Purdy, J.A.1
  • 4
    • 0018758746 scopus 로고
    • Improving the build-up and depth-dose characteristics of high energy, photon beams bv using electron filters
    • Ling, C. C. and Biggs, P. J., Improving the build-up and depth-dose characteristics of high energy, photon beams bv using electron filters, Med. Phys. 6 (4), 296-301, 1979.
    • (1979) Med. Phys. , vol.6 , Issue.4 , pp. 296-301
    • Ling, C.C.1    Biggs, P.J.2
  • 5
    • 0029845005 scopus 로고    scopus 로고
    • Electron contamination in clinical high energy photon beams
    • Sjogren, R. and Karlsson, M., Electron contamination in clinical high energy photon beams, Med. Phys. 23 (11), 1873-1881, 1996.
    • (1996) Med. Phys. , vol.23 , Issue.11 , pp. 1873-1881
    • Sjogren, R.1    Karlsson, M.2
  • 6
    • 0021946951 scopus 로고
    • Electron contamination from different materials in high energy, photon beams
    • Nilsson, B., Electron contamination from different materials in high energy, photon beams, Phys. Med. Biol. 30, 139-151, 1985.
    • (1985) Phys. Med. Biol. , vol.30 , pp. 139-151
    • Nilsson, B.1
  • 7
    • 0030440153 scopus 로고    scopus 로고
    • Characteristics of secondary electrons produced by 6,10 and 24 MV x-ray beams
    • Jursinic, P. A. and Mackie TR., Characteristics of secondary electrons produced by 6,10 and 24 MV x-ray beams, Phys. Med. Biol. 41, 1499-1509, 1996.
    • (1996) Phys. Med. Biol. , vol.41 , pp. 1499-1509
    • Jursinic, P.A.1    Mackie, T.R.2
  • 8
    • 0020037703 scopus 로고
    • Magnetic analysis of the radiation components of a 10 MV photon beam
    • Ling, C. C., Schell, M. C., et al., Magnetic analysis of the radiation components of a 10 MV photon beam, Med. Phys. 9 (1), 20-26, 1982.
    • (1982) Med. Phys. , vol.9 , Issue.1 , pp. 20-26
    • Ling, C.C.1    Schell, M.C.2
  • 9
    • 85039213976 scopus 로고    scopus 로고
    • AMF Magnetics, Unit 1/26 Wentworth Ave Mascot NSW 2020 Australia
    • AMF Magnetics, Unit 1/26 Wentworth Ave Mascot NSW 2020 Australia.
  • 10
    • 85039199545 scopus 로고    scopus 로고
    • John Beeteson Web Page created Accessed Nov 2005
    • John Beeteson Web Page created 2003: http://www.vizimag.com Accessed Nov 2005.
    • (2003)
  • 11
    • 85039227824 scopus 로고    scopus 로고
    • Vizimag 3.0 tutorial Copyright
    • Beeteson, J. S., Vizimag 3.0 tutorial Copyright, 2004.
    • (2004)
    • Beeteson, J.S.1
  • 12
    • 0020137053 scopus 로고
    • A solid water phantom material for radiotherapy X-ray and gamma ray beam ray, calculations
    • Constanitinou, C., Attix, F. and Paliwal, B., A solid water phantom material for radiotherapy X-ray and gamma ray beam ray, calculations, Med Phys. 9 (3), 436-441, 1982.
    • (1982) Med Phys. , vol.9 , Issue.3 , pp. 436-441
    • Constanitinou, C.1    Attix, F.2    Paliwal, B.3
  • 13
    • 0026695986 scopus 로고
    • Newcombe D, Design of parallel plate ion chambers for build up measurements in megavoltage photon beams
    • Rawlinson, J. A. and Arien, D., Newcombe D, Design of parallel plate ion chambers for build up measurements in megavoltage photon beams, Med Phys. 19 (3), 641-648, 1992.
    • (1992) Med Phys. , vol.19 , Issue.3 , pp. 641-648
    • Rawlinson, J.A.1    Arien, D.2
  • 14
    • 0025916626 scopus 로고
    • Bonnefoux I, Complications in low energy x-ray dosimetry caused by electron contamination
    • Klevenhagen, S. C. and D'Souza D., Bonnefoux I, Complications in low energy x-ray dosimetry caused by electron contamination. Phys. Med. Biol. 36 (8), 1111-1116, 1991.
    • (1991) Phys. Med. Biol. , vol.36 , Issue.8 , pp. 1111-1116
    • Klevenhagen, S.C.1    D'Souza, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.