Transesophageal echocardiography and intracardiac echocardiography differently predict potential technical challenges or failures of interatrial shunts catheter-based closure

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; DIAGNOSTIC ERROR; ECHOCARDIOGRAPHY; FEMALE; FLUOROSCOPY; FOLLOW UP; HEART ATRIUM SEPTUM DEFECT; HUMAN; MALE; PRIORITY JOURNAL; SCREENING; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; VEIN VALVE;

EID: 33846486910     PISSN: 08964327     EISSN: 15408183     Source Type: Journal    
DOI: 10.1111/j.1540-8183.2007.00219.x     Document Type: Article
Times cited : (26)

References (14)
  • 1
    • 28444462483 scopus 로고    scopus 로고
    • Atrial and ventricular septal defects can safely be closed by percutaneous intervention
    • Hein R, Buscheck F, Fischer E, et al. Atrial and ventricular septal defects can safely be closed by percutaneous intervention. J Interven Cardiol 2005;18:515-522.
    • (2005) J Interven Cardiol , vol.18 , pp. 515-522
    • Hein, R.1    Buscheck, F.2    Fischer, E.3
  • 2
    • 0242720939 scopus 로고    scopus 로고
    • Intracardiac echocardiography-guided transcatheter closure of secundum atrial septal defect: A new efficient device selection method
    • Zanchetta M, Onorato E, Rigateli G, et al. Intracardiac echocardiography-guided transcatheter closure of secundum atrial septal defect: A new efficient device selection method. J Am Coll Cardiol 2003;42:1677-1682.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 1677-1682
    • Zanchetta, M.1    Onorato, E.2    Rigateli, G.3
  • 3
    • 33744968634 scopus 로고    scopus 로고
    • Intracardiac echocardiography in cardiovascular catheter-based interventions: Different devices for different purposes
    • Rigateli G, Hijazi ZM. Intracardiac echocardiography in cardiovascular catheter-based interventions: Different devices for different purposes. J Invasive Cardiol 2006;18:225-233.
    • (2006) J Invasive Cardiol , vol.18 , pp. 225-233
    • Rigateli, G.1    Hijazi, Z.M.2
  • 4
    • 0036196291 scopus 로고    scopus 로고
    • Persistent redundant Eustachian valve interfering with Amplatzer PFO occluder placement: Anatomico-clinical and technical implications
    • Onorato E, Pera IG, Melzi G, et al. Persistent redundant Eustachian valve interfering with Amplatzer PFO occluder placement: Anatomico-clinical and technical implications. Catheter Cardiovasc Interv 2002; 55:521-524.
    • (2002) Catheter Cardiovasc Interv , vol.55 , pp. 521-524
    • Onorato, E.1    Pera, I.G.2    Melzi, G.3
  • 6
    • 32944459711 scopus 로고    scopus 로고
    • American Society of Echocardiography's Nomenclature and Standards Committee; Task Force on Chamber Quantification; American College of Cardiology Echocardiography Committee; American Heart Association; European Association of Echocardiography, European Society of Cardiology. Recommendations for chamber quantification
    • Lang RM, Bierig M, Devereux RB, et al., American Society of Echocardiography's Nomenclature and Standards Committee; Task Force on Chamber Quantification; American College of Cardiology Echocardiography Committee; American Heart Association; European Association of Echocardiography, European Society of Cardiology. Recommendations for chamber quantification. Eur J Echocardiogr 2006;7:79-108.
    • (2006) Eur J Echocardiogr , vol.7 , pp. 79-108
    • Lang, R.M.1    Bierig, M.2    Devereux, R.B.3
  • 7
    • 0033549030 scopus 로고    scopus 로고
    • Potential source of cerebral embolism in migraine with aura: A transcranial Doppler study
    • Anzola GP, Magoni M, Guindani M, et al. Potential source of cerebral embolism in migraine with aura: A transcranial Doppler study. Neurology 1999;52:1622-1625.
    • (1999) Neurology , vol.52 , pp. 1622-1625
    • Anzola, G.P.1    Magoni, M.2    Guindani, M.3
  • 8
    • 23744516333 scopus 로고    scopus 로고
    • Intracardiac echocardiography: Gross anatomy and magnetic resonance correlations and validations
    • Zanchetta M, Rigateli G, Pedon L, et al. Intracardiac echocardiography: Gross anatomy and magnetic resonance correlations and validations. Int J Cardiovasc Imaging 2005;21:391-401.
    • (2005) Int J Cardiovasc Imaging , vol.21 , pp. 391-401
    • Zanchetta, M.1    Rigateli, G.2    Pedon, L.3
  • 9
    • 0029051940 scopus 로고
    • Chiari's network: Normal anatomic variant or risk factor for arterial embolic events?
    • Schneider B, Hofmann T, Justen MH, et al. Chiari's network: Normal anatomic variant or risk factor for arterial embolic events? J Am Coll Cardiol 1995;26:203-210
    • (1995) J Am Coll Cardiol , vol.26 , pp. 203-210
    • Schneider, B.1    Hofmann, T.2    Justen, M.H.3
  • 10
    • 0027321632 scopus 로고
    • Echocardiographic follow-up of atrial septal defect after catheter closure by double-umbrella device
    • Boutin C, Musewe NN, Smallhorn JF, et al. Echocardiographic follow-up of atrial septal defect after catheter closure by double-umbrella device. Circulation 1993;88:621-627.
    • (1993) Circulation , vol.88 , pp. 621-627
    • Boutin, C.1    Musewe, N.N.2    Smallhorn, J.F.3
  • 11
    • 6344233578 scopus 로고    scopus 로고
    • Echocardiographic characteristics of secundum-type atrial septal defects in adult patients: Implications for percutaneous closure using Amplatzer septal occluders
    • Prokselj K, Kozelj M, Zadnik V, et al. Echocardiographic characteristics of secundum-type atrial septal defects in adult patients: Implications for percutaneous closure using Amplatzer septal occluders. J Am Soc Echocardiogr 2004;17:1167-1172.
    • (2004) J Am Soc Echocardiogr , vol.17 , pp. 1167-1172
    • Prokselj, K.1    Kozelj, M.2    Zadnik, V.3
  • 12
    • 0037630124 scopus 로고    scopus 로고
    • Intracardiac echocardiography evaluation in secundum atrial septal defect transcatheter closure
    • Zanchetta M, Pedon L, Rigateli G, et al. Intracardiac echocardiography evaluation in secundum atrial septal defect transcatheter closure. Cardiovasc Intervent Radiol 2003;26:52-57.
    • (2003) Cardiovasc Intervent Radiol , vol.26 , pp. 52-57
    • Zanchetta, M.1    Pedon, L.2    Rigateli, G.3
  • 13
    • 0035143017 scopus 로고    scopus 로고
    • Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: Feasibility and comparison with transesophageal echocardiography
    • Hijazi Z, Wang Z, Cao Q, et al. Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: Feasibility and comparison with transesophageal echocardiography. Catheter Cardiovasc Interv 2001;52:194-199.
    • (2001) Catheter Cardiovasc Interv , vol.52 , pp. 194-199
    • Hijazi, Z.1    Wang, Z.2    Cao, Q.3
  • 14
    • 0037108122 scopus 로고    scopus 로고
    • Comparison of transcatheter closure of secundum atrial septal defect using the Amplatzer septal occluder associated with deficient versus sufficient rims
    • Du ZD, Koenig P, Cao QL, et al. Comparison of transcatheter closure of secundum atrial septal defect using the Amplatzer septal occluder associated with deficient versus sufficient rims. Am J Cardiol 2002;90:865-869.
    • (2002) Am J Cardiol , vol.90 , pp. 865-869
    • ZD, D.1    Koenig, P.2    Cao, Q.L.3