Volumn 29, Issue 12, 2006, Pages 1174-1184

Tribological characterization of surface-treated commercially pure titanium for femoral heads in total hip replacement: A feasibility study

Author keywords

CoCrMo; Surface treatments; Titanium; Total hip replacement; Wear properties

Indexed keywords

ARTHROPLASTY; BIOCOMPATIBILITY; COBALT ALLOYS; HIP PROSTHESES; MOLYBDENUM ALLOYS; NONMETALLIC MATRIX COMPOSITES; SURFACE TREATMENT; TERNARY ALLOYS; TITANIUM ALLOYS; TRIBOLOGY; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES; WEAR OF MATERIALS; WEAR RESISTANCE;

EID: 33846473250     PISSN: 03913988     EISSN: None     Source Type: Journal    
DOI: 10.1177/039139880602901211     Document Type: Article
Times cited : (6)

References (25)
  • 1
    • 33846472023 scopus 로고    scopus 로고
    • Information for physicians who believe they may have a patient with a sensitivity to metal
    • Available at:
    • Information for physicians who believe they may have a patient with a sensitivity to metal. Available at: www.zimmer.com.
  • 2
    • 0035108321 scopus 로고    scopus 로고
    • Metal sensitivity in patients with orthopaedic implants
    • Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg (Am) 2001; 83: 428-33.
    • (2001) J Bone Joint Surg (Am) , vol.83 , pp. 428-433
    • Hallab, N.1    Merritt, K.2    Jacobs, J.J.3
  • 4
    • 0344553484 scopus 로고    scopus 로고
    • Biomaterials in orthopaedic surgery: Effects of a nickel-reduced stainless steel on in vitro proliferation and activation of human osteoblasts
    • Torricelli P, Fini M, Borsari V, Lenger H, Bernauer J, Tschon M, Bonazzi V, Giardino R. Biomaterials in orthopaedic surgery: effects of a nickel-reduced stainless steel on in vitro proliferation and activation of human osteoblasts. Int J Artif Organs 2003; 26: 952-7.
    • (2003) Int J Artif Organs , vol.26 , pp. 952-957
    • Torricelli, P.1    Fini, M.2    Borsari, V.3    Lenger, H.4    Bernauer, J.5    Tschon, M.6    Bonazzi, V.7    Giardino, R.8
  • 5
    • 0027897650 scopus 로고
    • In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling
    • Gilbert JL, Buckley CA, Jacobs JJ. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. J Biomed Mater Res 1993; 27: 1533-44.
    • (1993) J Biomed Mater Res , vol.27 , pp. 1533-1544
    • Gilbert, J.L.1    Buckley, C.A.2    Jacobs, J.J.3
  • 6
    • 33645961394 scopus 로고    scopus 로고
    • The role of fretting damage in total hip arthroplasty with modular design hip joints - Evaluation of retrieval studies and experimental simulation methods
    • Schaaff P. The role of fretting damage in total hip arthroplasty with modular design hip joints - evaluation of retrieval studies and experimental simulation methods. Journal of Applied Biomaterials & Biomechanics 2004; 2: 121-35.
    • (2004) Journal of Applied Biomaterials & Biomechanics , vol.2 , pp. 121-135
    • Schaaff, P.1
  • 7
    • 0043238148 scopus 로고    scopus 로고
    • Howse II cemented titanium metal-backed acetabular cups: Poor 10-year results in 107 hips
    • Mohan R, Grigoris P, Johnstone F, Hamblen DL. Howse II cemented titanium metal-backed acetabular cups: poor 10-year results in 107 hips. Acta Orthop Scand 2003; 74: 397-403.
    • (2003) Acta Orthop Scand , vol.74 , pp. 397-403
    • Mohan, R.1    Grigoris, P.2    Johnstone, F.3    Hamblen, D.L.4
  • 8
    • 1842681798 scopus 로고    scopus 로고
    • Pulsed laser deposition of titanium oxide at room temperature - Structural, mechanical and tribological properties
    • Lackner JM, Waldhauser R, Ebner R, Major B, Schöberl T. Pulsed laser deposition of titanium oxide at room temperature - structural, mechanical and tribological properties. Surface and Coatings Technology 2004; 180-181: 585-90.
    • (2004) Surface and Coatings Technology , vol.180-181 , pp. 585-590
    • Lackner, J.M.1    Waldhauser, R.2    Ebner, R.3    Major, B.4    Schöberl, T.5
  • 10
    • 33846480653 scopus 로고    scopus 로고
    • Improving wear resistance by heat-treatment in different atmospheres
    • Feng B, Weng J, Qu SX, Leng YX, Zhou ZR. Improving wear resistance by heat-treatment in different atmospheres. Key Engineering Materials 2005; 288-289: 641-4.
    • (2005) Key Engineering Materials , vol.288-289 , pp. 641-644
    • Feng, B.1    Weng, J.2    Qu, S.X.3    Leng, Y.X.4    Zhou, Z.R.5
  • 11
    • 24944541844 scopus 로고    scopus 로고
    • Influence of laser surface modification on corrosion behaviour of stainless steel 316L and Ti-6AI-4V in simulated biofluid
    • Singh R, Martin M, Dahotre NB. Influence of laser surface modification on corrosion behaviour of stainless steel 316L and Ti-6AI-4V in simulated biofluid. Surface Engineering 2005; 21: 297-306.
    • (2005) Surface Engineering , vol.21 , pp. 297-306
    • Singh, R.1    Martin, M.2    Dahotre, N.B.3
  • 12
    • 12344298672 scopus 로고    scopus 로고
    • Surface modification of titanium, titanium alloys and related materials for biomedical applications
    • R 47
    • Liu X, Chu PK, Ding C. Surface modification of titanium, titanium alloys and related materials for biomedical applications. Materials Science and Engineering 2004; R 47: 49-121.
    • (2004) Materials Science and Engineering , pp. 49-121
    • Liu, X.1    Chu, P.K.2    Ding, C.3
  • 14
    • 33846514766 scopus 로고    scopus 로고
    • Method of coloring titanium and its alloys through anodic oxidation
    • Patent EP 1 199 385 A2 - 19.10.2000
    • Pedeferri P. Method of coloring titanium and its alloys through anodic oxidation. Patent EP 1 199 385 A2 - 19.10.2000 (2000).
    • (2000)
    • Pedeferri, P.1
  • 15
  • 16
    • 33846523031 scopus 로고
    • US Patent 5,185075
    • Rosenberg HW. US Patent 5,185075; (1993).
    • (1993)
    • Rosenberg, H.W.1
  • 19
    • 0038699514 scopus 로고    scopus 로고
    • Laser surface processing of titanium in air: Influence of scan traces overlapping
    • Perez del Pino A, Serra P, Morenza JL. Laser surface processing of titanium in air: Influence of scan traces overlapping. J Laser Appl 2003; 15: 120-3.
    • (2003) J Laser Appl , vol.15 , pp. 120-123
    • Perez del Pino, A.1    Serra, P.2    Morenza, J.L.3
  • 20
    • 0002989262 scopus 로고
    • Forces transmitted by joints in the human body
    • Paul JP. Forces transmitted by joints in the human body. Proc Inst Mech Eng 1967; 181: 8-15.
    • (1967) Proc Inst Mech Eng , vol.181 , pp. 8-15
    • Paul, J.P.1
  • 22
    • 33846480053 scopus 로고    scopus 로고
    • Standard practice for gravimetric measurement of polymeric components for wear assessment
    • Standard F2025-00. West Conshohocken, PA, USA. American Society for Testing and Materials
    • Standard F2025-00. Standard practice for gravimetric measurement of polymeric components for wear assessment. West Conshohocken, PA, USA. American Society for Testing and Materials, 2003.
    • (2003)
  • 23
    • 0035694550 scopus 로고    scopus 로고
    • Effects of laser hardening on fretting wear behaviour of Ti alloy
    • Zhang H, Dai D, Shi Y, Xu CY. Effects of laser hardening on fretting wear behaviour of Ti alloy. Surface Engineering 2001; 17: 518-20.
    • (2001) Surface Engineering , vol.17 , pp. 518-520
    • Zhang, H.1    Dai, D.2    Shi, Y.3    Xu, C.Y.4
  • 25
    • 23944457404 scopus 로고    scopus 로고
    • Surface modification for bioimplants: The role of laser surface engineering
    • Kurella A, Dahotre NB. Surface modification for bioimplants: the role of laser surface engineering. J Biomater Appl 2005; 20: 5-50.
    • (2005) J Biomater Appl , vol.20 , pp. 5-50
    • Kurella, A.1    Dahotre, N.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.