메뉴 건너뛰기




Volumn 16, Issue 1, 2007, Pages 31-36

Shear bond strength evaluation of different veneering systems on Ni-Cr alloys

Author keywords

Bonding systems; Composite resin; Fixed prosthodontics; Resin bonding; Shear bond strength

Indexed keywords

ALLOY; ALUMINUM OXIDE; BIODENT; BIOMEDICAL AND DENTAL MATERIALS; CHROMIUM DERIVATIVE; DENTAL ALLOY; DENTAL POLYGLASS; GLASS IONOMER; SILICATE CEMENT; UNCLASSIFIED DRUG; VITA VMK 68;

EID: 33846463059     PISSN: 1059941X     EISSN: 1532849X     Source Type: Journal    
DOI: 10.1111/j.1532-849X.2006.00148.x     Document Type: Article
Times cited : (17)

References (18)
  • 1
    • 0038716765 scopus 로고    scopus 로고
    • Shear bond strength of aesthetic materials bonded to Ni-Cr alloy
    • Almilhatti HJ, Giampaolo ET, Vergani CE, et al: Shear bond strength of aesthetic materials bonded to Ni-Cr alloy. J Dent 2003;31:205-211
    • (2003) J Dent , vol.31 , pp. 205-211
    • Almilhatti, H.J.1    Giampaolo, E.T.2    Vergani, C.E.3
  • 2
    • 0033226954 scopus 로고    scopus 로고
    • Shear bond strength of techniques for bonding esthetic veneers to metal
    • Petridis H, Hirayama H, Kugel G, et al: Shear bond strength of techniques for bonding esthetic veneers to metal. J Prosthet Dent 1999;82:608-614
    • (1999) J Prosthet Dent , vol.82 , pp. 608-614
    • Petridis, H.1    Hirayama, H.2    Kugel, G.3
  • 3
    • 0031201534 scopus 로고    scopus 로고
    • Bond strengths of resin-to-metal bonding systems
    • Kourtis SG: Bond strengths of resin-to-metal bonding systems. J Prosthet Dent 1997;78:136-145
    • (1997) J Prosthet Dent , vol.78 , pp. 136-145
    • Kourtis, S.G.1
  • 4
    • 0142155594 scopus 로고    scopus 로고
    • Evaluation of shear bond strength of composite to porcelain according to surface treatment
    • Kussano CM, Bonfante G, Batista JG, et al: Evaluation of shear bond strength of composite to porcelain according to surface treatment. Braz Dent J 2003;14:132-135
    • (2003) Braz Dent J , vol.14 , pp. 132-135
    • Kussano, C.M.1    Bonfante, G.2    Batista, J.G.3
  • 5
    • 0036512555 scopus 로고    scopus 로고
    • Probability of failure of highly filled indirect resin-veneered implant-supported restorations: An in vitro study
    • Takahashi Y, Hisama K, Safo H, et al: Probability of failure of highly filled indirect resin-veneered implant-supported restorations: an in vitro study. Int J Prosthodont 2002;15:179-182
    • (2002) Int J Prosthodont , vol.15 , pp. 179-182
    • Takahashi, Y.1    Hisama, K.2    Safo, H.3
  • 6
    • 0033210779 scopus 로고    scopus 로고
    • Effect of sand-blasting and silicoating on bond strength of polymer-glass composite to cast titanium
    • Watanabe I, Kurtz KS, Kabcenell JL, et al: Effect of sand-blasting and silicoating on bond strength of polymer-glass composite to cast titanium. J Prosthet Dent 1999;82:462-467
    • (1999) J Prosthet Dent , vol.82 , pp. 462-467
    • Watanabe, I.1    Kurtz, K.S.2    Kabcenell, J.L.3
  • 7
    • 0030095466 scopus 로고    scopus 로고
    • Shear bond strengths of three resin cements used with three adhesive primers for metal
    • Yoshida K, Kamada K, Tanagawa M, et al: Shear bond strengths of three resin cements used with three adhesive primers for metal. J Prosthet Dent 1996;75:254-261
    • (1996) J Prosthet Dent , vol.75 , pp. 254-261
    • Yoshida, K.1    Kamada, K.2    Tanagawa, M.3
  • 8
    • 0031174876 scopus 로고    scopus 로고
    • Tensile strength and microleakage of the bond between a nickel-chromium alloy and a visible light-cured resin composite: Effect of 4-META, silicoating, and bead retention
    • Tulunoglu IF, Oktemer M: Tensile strength and microleakage of the bond between a nickel-chromium alloy and a visible light-cured resin composite: effect of 4-META, silicoating, and bead retention. Quintessence Int 1997;28:447-451
    • (1997) Quintessence Int , vol.28 , pp. 447-451
    • Tulunoglu, I.F.1    Oktemer, M.2
  • 9
    • 0142093511 scopus 로고    scopus 로고
    • Effect of laboratory procedures and thermocycling on the shear bond strength of resin-metal bonding systems
    • Kim JY, Pfeiffer P, Niedermeier W: Effect of laboratory procedures and thermocycling on the shear bond strength of resin-metal bonding systems. J Prosthet Dent 2003;90:184-189
    • (2003) J Prosthet Dent , vol.90 , pp. 184-189
    • Kim, J.Y.1    Pfeiffer, P.2    Niedermeier, W.3
  • 10
    • 0035458349 scopus 로고    scopus 로고
    • Shear bond strength of resin composite veneering material to gold alloy with varying metal surface preparations
    • Matsumura H, Yanagida H, Tanoue N, et al: Shear bond strength of resin composite veneering material to gold alloy with varying metal surface preparations. J Prosthet Dent 2001;86:315-319
    • (2001) J Prosthet Dent , vol.86 , pp. 315-319
    • Matsumura, H.1    Yanagida, H.2    Tanoue, N.3
  • 11
    • 0036482049 scopus 로고    scopus 로고
    • Adhesive bonding of composite material to cast titanium with varying surface preparations
    • Yanagida H, Matsumura H, Taira Y, et al: Adhesive bonding of composite material to cast titanium with varying surface preparations. J Oral Rehabil 2002;29:121-126
    • (2002) J Oral Rehabil , vol.29 , pp. 121-126
    • Yanagida, H.1    Matsumura, H.2    Taira, Y.3
  • 12
    • 0035749863 scopus 로고    scopus 로고
    • Tensile bond strength of composite repairs on Artglass using different surface treatments
    • Cesar PF, Meyer Faara PM, Miwa Caldart R, et al: Tensile bond strength of composite repairs on Artglass using different surface treatments. Am J Dent 2001;14:373-377
    • (2001) Am J Dent , vol.14 , pp. 373-377
    • Cesar, P.F.1    Meyer Faara, P.M.2    Miwa Caldart, R.3
  • 13
    • 0022732872 scopus 로고
    • The adhesion mechanism of dental adhesive resin to the alloy - relationship between Co-Cr alloy surface structure analyzed by ESCA and bonding strength of adhesive resin
    • Ohno H, Araki Y, Sagara M: The adhesion mechanism of dental adhesive resin to the alloy - relationship between Co-Cr alloy surface structure analyzed by ESCA and bonding strength of adhesive resin. Dent Mater J 1986;5:46-65
    • (1986) Dent Mater J , vol.5 , pp. 46-65
    • Ohno, H.1    Araki, Y.2    Sagara, M.3
  • 14
    • 0026113427 scopus 로고
    • Microleakage and shear bond strength of resin and porcelain veneers bonded to cast alloys
    • Jones RM, Moore BK, Goodacre CJ, et al: Microleakage and shear bond strength of resin and porcelain veneers bonded to cast alloys. J Prosthet Dent 1991;65:221-228
    • (1991) J Prosthet Dent , vol.65 , pp. 221-228
    • Jones, R.M.1    Moore, B.K.2    Goodacre, C.J.3
  • 15
    • 0033146141 scopus 로고    scopus 로고
    • Adhesive primers for bonding cobalt-chromium alloy to resin
    • Yoshida K, Kamada K, Atsuta M: Adhesive primers for bonding cobalt-chromium alloy to resin. J Oral Rehabil 1999;26:475-478
    • (1999) J Oral Rehabil , vol.26 , pp. 475-478
    • Yoshida, K.1    Kamada, K.2    Atsuta, M.3
  • 16
    • 0032254020 scopus 로고    scopus 로고
    • Bond strength of acrylic resin to cobalt-chromium alloy treated with the Silicoater MD and Kevloc systems
    • Pesun S, Mazurat RD: Bond strength of acrylic resin to cobalt-chromium alloy treated with the Silicoater MD and Kevloc systems. J Can Dent Assoc 1998;64:798-802
    • (1998) J Can Dent Assoc , vol.64 , pp. 798-802
    • Pesun, S.1    Mazurat, R.D.2
  • 17
    • 0026177779 scopus 로고
    • Microleakage at the resin-alloy interface of chemically retained composite resins for cast restorations
    • Strygler H, Nicholls J, Townsend JD: Microleakage at the resin-alloy interface of chemically retained composite resins for cast restorations. J Prosthet Dent 1991;65:733-739
    • (1991) J Prosthet Dent , vol.65 , pp. 733-739
    • Strygler, H.1    Nicholls, J.2    Townsend, J.D.3
  • 18
    • 0031308176 scopus 로고    scopus 로고
    • Second generation laboratory composite resins for indirect restorations
    • Touati B, Aidan N: Second generation laboratory composite resins for indirect restorations. J Esthet Dent 1997;9:108-118
    • (1997) J Esthet Dent , vol.9 , pp. 108-118
    • Touati, B.1    Aidan, N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.