메뉴 건너뛰기




Volumn 41, Issue 2, 2007, Pages 138-140

Going for the loop: A unique overtube for the difficult colonoscopy

Author keywords

Colonoscopy; Difficult endoscopy; Enteroscopy; Loop; Looping; Over tube; Shape lock; ShapeLock; Transgastric endoscopy; Variable stiffness

Indexed keywords

COLONOSCOPY; DEVICE; DIGESTIVE TRACT ENDOSCOPY; DIGESTIVE TRACT INTUBATION; FOOD AND DRUG ADMINISTRATION; GASTROINTESTINAL ENDOSCOPE; GASTROINTESTINAL ENDOSCOPY; HUMAN; INTESTINE PERFORATION; MEDICAL INSTRUMENTATION; NONHUMAN; PRIORITY JOURNAL; REVIEW; SIGMOID; UPPER GASTROINTESTINAL TRACT;

EID: 33846406405     PISSN: 01920790     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.mcg.0000225595.01201.d2     Document Type: Review
Times cited : (26)

References (21)
  • 4
    • 0036618106 scopus 로고    scopus 로고
    • Usefulness of a pediatric colonoscope for routine colonoscopy in women who have undergone hysterectomy
    • Marshall JB, Perez RA, Madsen RW. Usefulness of a pediatric colonoscope for routine colonoscopy in women who have undergone hysterectomy. Gastrointest Endosc. 2002;55:838-841.
    • (2002) Gastrointest Endosc , vol.55 , pp. 838-841
    • Marshall, J.B.1    Perez, R.A.2    Madsen, R.W.3
  • 5
    • 0034015814 scopus 로고    scopus 로고
    • Usefulness of a pediatric colonoscope for colonoscopy in adults
    • Saifuddin T, Trivedi M, King PD, et al. Usefulness of a pediatric colonoscope for colonoscopy in adults. Gastrointest Endosc. 2000;51:314-317.
    • (2000) Gastrointest Endosc , vol.51 , pp. 314-317
    • Saifuddin, T.1    Trivedi, M.2    King, P.D.3
  • 6
    • 0141817857 scopus 로고    scopus 로고
    • Colonoscopy with the variable stiffness colonoscope
    • Ginsberg GG. Colonoscopy with the variable stiffness colonoscope. Gastrointest Endosc. 2003;58:579-584.
    • (2003) Gastrointest Endosc , vol.58 , pp. 579-584
    • Ginsberg, G.G.1
  • 7
    • 0036480120 scopus 로고    scopus 로고
    • A randomized controlled trial in a training institution comparing a pediatric variable stiffness colonoscope, a pediatric colonoscope and an adult colonoscope
    • Shumaker DA, Zaman A, Katon RM. A randomized controlled trial in a training institution comparing a pediatric variable stiffness colonoscope, a pediatric colonoscope and an adult colonoscope. Gastrointest Endosc. 2002;55:172-179.
    • (2002) Gastrointest Endosc , vol.55 , pp. 172-179
    • Shumaker, D.A.1    Zaman, A.2    Katon, R.M.3
  • 8
    • 0036895952 scopus 로고    scopus 로고
    • Variable stiffness colonoscopes are associated with less pain during colonoscopy in unsedated patients
    • Yoshikawa I, Honda H, Nagata K, et al. Variable stiffness colonoscopes are associated with less pain during colonoscopy in unsedated patients. Am J Gastroenterol. 2002;97:3052-3055.
    • (2002) Am J Gastroenterol , vol.97 , pp. 3052-3055
    • Yoshikawa, I.1    Honda, H.2    Nagata, K.3
  • 9
    • 0035347248 scopus 로고    scopus 로고
    • Clinical application of a new colonoscope with variable insertion tube rigidity: A pilot study
    • Sorbi D, Schleck CD, Zinsmeister AR, et al. Clinical application of a new colonoscope with variable insertion tube rigidity: a pilot study. Gastrointest Endosc. 2001;53:638-642.
    • (2001) Gastrointest Endosc , vol.53 , pp. 638-642
    • Sorbi, D.1    Schleck, C.D.2    Zinsmeister, A.R.3
  • 10
    • 0034074393 scopus 로고    scopus 로고
    • A new variable stiffness colonoscope makes colonoscopy easier: A randomised controlled trial
    • Brooker JC, Saunders BP, Shah SG, et al. A new variable stiffness colonoscope makes colonoscopy easier: a randomised controlled trial. Gut. 2000;46:801.
    • (2000) Gut , vol.46 , pp. 801
    • Brooker, J.C.1    Saunders, B.P.2    Shah, S.G.3
  • 12
    • 0034948809 scopus 로고    scopus 로고
    • Effect of variable stiffness colonoscopes on cecal intubation times for routine colonoscopy by an experienced examiner in sedated patients
    • Rex DK. Effect of variable stiffness colonoscopes on cecal intubation times for routine colonoscopy by an experienced examiner in sedated patients. Endoscopy. 2001;33:60-64.
    • (2001) Endoscopy , vol.33 , pp. 60-64
    • Rex, D.K.1
  • 13
    • 0021289153 scopus 로고
    • Colonoscopy with a videoendoscope: Preliminary experience
    • Sivak MV Jr, Fleischer DE. Colonoscopy with a videoendoscope: preliminary experience. Gastrointest Endosc. 1984;30:1-5.
    • (1984) Gastrointest Endosc , vol.30 , pp. 1-5
    • Sivak Jr, M.V.1    Fleischer, D.E.2
  • 15
    • 33344477634 scopus 로고    scopus 로고
    • The aer-o-scope: Proof of concept of a pneumatic, skill-independent, self-propelling, self-navigating colonoscope
    • Vucelic B, Rex D, Pulanic R, et al. The aer-o-scope: proof of concept of a pneumatic, skill-independent, self-propelling, self-navigating colonoscope. Gastroenterology. 2006;130:672-677.
    • (2006) Gastroenterology , vol.130 , pp. 672-677
    • Vucelic, B.1    Rex, D.2    Pulanic, R.3
  • 16
    • 33846434876 scopus 로고    scopus 로고
    • Eickhoff A, Riemann J, Van Dam J. Determining scope position during colonoscopy without the use of ionizing radiation or magnetic field: the enhanced mapping ability of the Neoguide Endoscopy System. Gastrointest Endosc. 2006;63:DDW abstract issue, (T1501).
    • Eickhoff A, Riemann J, Van Dam J. Determining scope position during colonoscopy without the use of ionizing radiation or magnetic field: the enhanced mapping ability of the Neoguide Endoscopy System. Gastrointest Endosc. 2006;63:DDW abstract issue, (T1501).
  • 17
    • 33544462094 scopus 로고    scopus 로고
    • The colonoscope insertion tube
    • Waye JD, Rex DK, Williams CB, editors, Malden, MA: Blackwell Publishing;
    • Howell DA. The colonoscope insertion tube. In: Waye JD, Rex DK, Williams CB, editors. Colonoscopy Principles and Practice. Malden, MA: Blackwell Publishing; 2003:259-264.
    • (2003) Colonoscopy Principles and Practice , pp. 259-264
    • Howell, D.A.1
  • 18
    • 0025976818 scopus 로고
    • Colonoscope damage from internal straightener use
    • Ruffolo TA, Lehman GA, Rex D. Colonoscope damage from internal straightener use. Gastrointest Endosc. 1991;37:107-108.
    • (1991) Gastrointest Endosc , vol.37 , pp. 107-108
    • Ruffolo, T.A.1    Lehman, G.A.2    Rex, D.3
  • 19
    • 1542724576 scopus 로고    scopus 로고
    • A novel shape-locking guide for prevention of sigmoid looping during colonoscopy
    • Raju GS, Rex DK, Kozarek RA, et al. A novel shape-locking guide for prevention of sigmoid looping during colonoscopy. Gastrointest Endosc. 2004;59:416-419.
    • (2004) Gastrointest Endosc , vol.59 , pp. 416-419
    • Raju, G.S.1    Rex, D.K.2    Kozarek, R.A.3
  • 20
    • 23044445726 scopus 로고    scopus 로고
    • Advances in colonic imaging: Technical improvements in colonoscopy
    • Brown G, Saunders BP. Advances in colonic imaging: technical improvements in colonoscopy. Eur J Gastroenterol Hepatol. 2005; 17:785-792.
    • (2005) Eur J Gastroenterol Hepatol , vol.17 , pp. 785-792
    • Brown, G.1    Saunders, B.P.2
  • 21
    • 17544376956 scopus 로고    scopus 로고
    • Insertability and safety of a shape-locking device for colonoscopy
    • Rex DK, Khashab M, Raju GS, et al. Insertability and safety of a shape-locking device for colonoscopy. Am J Gastroenterol. 2005; 100:817-820.
    • (2005) Am J Gastroenterol , vol.100 , pp. 817-820
    • Rex, D.K.1    Khashab, M.2    Raju, G.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.