메뉴 건너뛰기




Volumn 17, Issue 11-12, 2006, Pages 872-877

A new polymeric silicone hydrogel for medical applications: Synthesis and properties

Author keywords

Hydrogels; Interpenetrating polymer networks (IPNs); N,N dimethylacrylamide; N vinyl pyrrolidone; Silicones

Indexed keywords

COPOLYMERIZATION; HYDROGELS; HYDROPHILICITY; INTERPENETRATING POLYMER NETWORKS; MECHANICAL PROPERTIES; MEDICAL APPLICATIONS; MONOMERS; OLIGOMERS; SYNTHESIS (CHEMICAL); TRANSPARENCY;

EID: 33846354661     PISSN: 10427147     EISSN: 10991581     Source Type: Journal    
DOI: 10.1002/pat.820     Document Type: Conference Paper
Times cited : (48)

References (17)
  • 1
    • 0038340395 scopus 로고    scopus 로고
    • Role of oxygen in corneal epithelial homeostasis during extended contact lens wear
    • Ladage PM, Jester JV, et al. Role of oxygen in corneal epithelial homeostasis during extended contact lens wear. Eye & Contact Lens. 2003; 29: 2-5.
    • (2003) Eye & Contact Lens. , vol.29 , pp. 2-5
    • Ladage, P.M.1    Jester, J.V.2
  • 2
    • 32044456909 scopus 로고    scopus 로고
    • Extended wear ophtalmic lens
    • US patent no. 5,965,631
    • Nicolson PC, et al. Extended wear ophtalmic lens. US patent no. 5,965,631, 1999.
    • (1999)
    • Nicolson, P.C.1
  • 3
    • 0742289638 scopus 로고    scopus 로고
    • Experimental study of albumin and lysozyme adsorption onto acrylic acid and 2-hydroxyethyl methacrylate surfaces
    • Moradi O, Modarress H, Noroozi M. Experimental study of albumin and lysozyme adsorption onto acrylic acid and 2-hydroxyethyl methacrylate surfaces. J. Col. Inter. Sci. 2004; 271: 16-19.
    • (2004) J. Col. Inter. Sci. , vol.271 , pp. 16-19
    • Moradi, O.1    Modarress, H.2    Noroozi, M.3
  • 4
    • 0038340386 scopus 로고    scopus 로고
    • Continuous wear contact lens surface chemistry and wearability
    • Nicolson PC. Continuous wear contact lens surface chemistry and wearability. Eye & Contact Lens. 2003; 29: 30-32.
    • (2003) Eye & Contact Lens. , vol.29 , pp. 30-32
    • Nicolson, P.C.1
  • 5
    • 33846371216 scopus 로고    scopus 로고
    • Soft contact lenses
    • US patent no. N 2002/0107324 A1
    • Vanderaan DG, et al. Soft contact lenses. US patent no. N 2002/0107324 A1, 2002.
    • (2002)
    • Vanderaan, D.G.1
  • 6
    • 33846369539 scopus 로고
    • Surface modification of polymer objects
    • US patent no. N 5219965
    • Valint PL Jr, et al. Surface modification of polymer objects. US patent no. N 5219965, 1993.
    • (1993)
    • Valint Jr., P.L.1
  • 7
    • 33846368829 scopus 로고
    • Silicone-vinyl acetate composition for contact lenses
    • US patent no. N 4500695
    • Ivani EJ. Silicone-vinyl acetate composition for contact lenses. US patent no. N 4500695, 1985.
    • (1985)
    • Ivani, E.J.1
  • 8
    • 33846353240 scopus 로고
    • Copolymer for soft contact lens, its preparation and soft contact lens made thereof
    • US patent no. N 4139513
    • Tanaka K, et al. Copolymer for soft contact lens, its preparation and soft contact lens made thereof. US patent no. N 4139513, 1979.
    • (1979)
    • Tanaka, K.1
  • 9
    • 33846358992 scopus 로고
    • Comfortable, oxygen permeable contact lenses and the manufacture thereof
    • US patent no. N 4948855
    • Novicky N. Comfortable, oxygen permeable contact lenses and the manufacture thereof. US patent no. N 4948855, 1990.
    • (1990)
    • Novicky, N.1
  • 10
    • 0001981525 scopus 로고    scopus 로고
    • Silicone hydrogels: The rebirth of continuous wear contact lenses
    • Sweeney D (ed.). Butterworth-Heinemann, Oxford
    • Tighe B. Silicone hydrogels: The rebirth of continuous wear contact lenses. Sweeney D (ed.). Butterworth-Heinemann, Oxford, 2000; 1-21.
    • (2000) , pp. 1-21
    • Tighe, B.1
  • 11
    • 33846397833 scopus 로고
    • Fluorosilicone hydrogels
    • US patent no. N 5321108
    • Kunzler J, Ozark R. Fluorosilicone hydrogels. US patent no. N 5321108, 1994.
    • (1994)
    • Kunzler, J.1    Ozark, R.2
  • 12
    • 33846365665 scopus 로고    scopus 로고
    • Hydrogel with internal wetting agent
    • US patent no. N 6367929
    • Maiden AC, Vanderllaan DG, Turner DC, et al. Hydrogel with internal wetting agent. US patent no. N 6367929, 2002.
    • (2002)
    • Maiden, A.C.1    Vanderllaan, D.G.2    Turner, D.C.3
  • 13
    • 33846386516 scopus 로고
    • Process for making silicone containing hydrogel lenses
    • US patent no. N 5260000
    • Makendra N, Rajan B, Chin LY. Process for making silicone containing hydrogel lenses. US patent no. N 5260000, 1993.
    • (1993)
    • Makendra, N.1    Rajan, B.2    Chin, L.Y.3
  • 14
    • 33846374788 scopus 로고
    • Training for chemistry of surface effects and adsorption
    • Vysshaya shkola: Moscow, (in Russian)
    • Ajvazov BV. Training for chemistry of surface effects and adsorption. Vysshaya shkola: Moscow, 1973; 24-25 (in Russian).
    • (1973) , pp. 24-25
    • Ajvazov, B.V.1
  • 15
    • 0021505306 scopus 로고
    • Observations relating to oxygen permeability measurements on membranes
    • Hitchman ML, Huglin MB, Zakaria MB. Observations relating to oxygen permeability measurements on membranes. Polymer 1994; 25: 1441-1445.
    • (1994) Polymer , vol.25 , pp. 1441-1445
    • Hitchman, M.L.1    Huglin, M.B.2    Zakaria, M.B.3
  • 16
    • 0342642760 scopus 로고    scopus 로고
    • Minimum contact lens transmissibility values for daily and extended wear lenses
    • Harvitt DV, Bonnano JA. Minimum contact lens transmissibility values for daily and extended wear lenses. Optometry and Vision Sci. 1998; 12: 189-203.
    • (1998) Optometry and Vision Sci. , vol.12 , pp. 189-203
    • Harvitt, D.V.1    Bonnano, J.A.2
  • 17
    • 33846373733 scopus 로고
    • Primary pharmacological test methods of biological-active substances
    • Medicina: Moscow, (in Russian)
    • Gacyra VV. Primary pharmacological test methods of biological-active substances. Medicina: Moscow, 1974; 120-138 (in Russian).
    • (1974) , pp. 120-138
    • Gacyra, V.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.