메뉴 건너뛰기




Volumn 220, Issue 8, 2006, Pages 881-887

Influence of acetabular rim profile on hip dislocation

Author keywords

Acetabular liner design; Biomechanics; Total hip replacement

Indexed keywords

COMPUTATIONAL GEOMETRY; DESIGN; HIP PROSTHESES; JOINTS (ANATOMY); BIOMECHANICS;

EID: 33846312143     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM174     Document Type: Article
Times cited : (3)

References (30)
  • 1
    • 0002098032 scopus 로고
    • Dislocation and instability
    • In (Ed. N. S. Eftekhar), (Mosby, St Louis, Missouri)
    • Eftekhar, N. S. Dislocation and instability. In Total hip arthroplasty (Ed. N. S. Eftekhar), 1993, pp. 1505-1553 (Mosby, St Louis, Missouri).
    • (1993) Total Hip Arthroplasty , pp. 1505-1553
    • Eftekhar, N.S.1
  • 2
    • 0020356121 scopus 로고
    • Dislocations after total hip arthroplasty
    • Woo, R. Y. and Morrey, B. F. Dislocations after total hip arthroplasty. J. Bone Jt Surg., 1982, 64A(9), 1295-1306.
    • (1982) J. Bone Jt Surg. , vol.64 A , Issue.9 , pp. 1295-1306
    • Woo, R.Y.1    Morrey, B.F.2
  • 3
    • 0032819104 scopus 로고    scopus 로고
    • Dislocation after total hip arthroplasty
    • Yuan, L. and Shih, C. Dislocation after total hip arthroplasty. Arch. Orthop. Trauma Surg., 1999, 119(5-6), 263-266.
    • (1999) Arch. Orthop. Trauma Surg. , vol.119 , Issue.5-6 , pp. 263-266
    • Yuan, L.1    Shih, C.2
  • 4
    • 0037398768 scopus 로고    scopus 로고
    • Kinematics, kinetics, and finite element analysis of common-place maneuvers at risk for total hip dislocation
    • Nadzadi, M. E., Pedersen, D. R., Yack, H. J., Callaghan, J. J., and Brown, T. D. Kinematics, kinetics, and finite element analysis of common-place maneuvers at risk for total hip dislocation. J. Biomechanics, 2003, 36(4), 577-591.
    • (2003) J. Biomechanics , vol.36 , Issue.4 , pp. 577-591
    • Nadzadi, M.E.1    Pedersen, D.R.2    Yack, H.J.3    Callaghan, J.J.4    Brown, T.D.5
  • 5
    • 0031733981 scopus 로고    scopus 로고
    • Posterior approach to total hip replacement using enhanced posterior soft tissue repair
    • Pellicci, P M., Bostrom, M., and Poss, R. Posterior approach to total hip replacement using enhanced posterior soft tissue repair. Clin. Orthop., 1998, (355), 224-228.
    • (1998) Clin. Orthop. , Issue.355 , pp. 224-228
    • Pellicci, P.M.1    Bostrom, M.2    Poss, R.3
  • 6
    • 0035216038 scopus 로고    scopus 로고
    • Recurrent dislocation after total hip arthroplasty: Treatment with an Achilles tendon allograft
    • Lavigne, M. J., Sanchez, A. A., and Coutts, R. D. Recurrent dislocation after total hip arthroplasty: treatment with an Achilles tendon allograft. J. Arthroplasty, 2001, 16(8), Suppl. 1, 13-18.
    • (2001) J. Arthroplasty , vol.16 , Issue.8 SUPPL. 1 , pp. 13-18
    • Lavigne, M.J.1    Sanchez, A.A.2    Coutts, R.D.3
  • 7
    • 0037899048 scopus 로고    scopus 로고
    • The incidence of dislocation after primary total hip arthroplasty using posterior approach with posterior soft-tissue repair
    • van Stralen, G. M., Struben, P. J., and van Loon, C. J. The incidence of dislocation after primary total hip arthroplasty using posterior approach with posterior soft-tissue repair. Arch. Orthop. Trauma Surg., 2003, 123(5), 219-222.
    • (2003) Arch. Orthop. Trauma Surg. , vol.123 , Issue.5 , pp. 219-222
    • van Stralen, G.M.1    Struben, P.J.2    van Loon, C.J.3
  • 8
    • 0034772076 scopus 로고    scopus 로고
    • Prevalence of dislocation after total hip arthroplasty through a posterolateral approach with partial capsulotomy and capsulorrhaphy
    • (Pt 1)
    • Goldstein, W. M., Gleason, T. F., Kopplin, M., and Branson, J. J. Prevalence of dislocation after total hip arthroplasty through a posterolateral approach with partial capsulotomy and capsulorrhaphy. J. Bone Jt Surg., 2001, 83A, Suppl. 2 (Pt 1), 2-7.
    • (2001) J. Bone Jt Surg. , vol.83 A , Issue.SUPPL. 2 , pp. 2-7
    • Goldstein, W.M.1    Gleason, T.F.2    Kopplin, M.3    Branson, J.J.4
  • 9
    • 0026766148 scopus 로고
    • Instability after total hip arthroplasty
    • Morrey, B. F. Instability after total hip arthroplasty. Orthop. Clin. North Am., 1992, 23(2), 237-248.
    • (1992) Orthop. Clin. North Am. , vol.23 , Issue.2 , pp. 237-248
    • Morrey, B.F.1
  • 10
    • 0034114175 scopus 로고    scopus 로고
    • The spatial location of impingement in total hip arthroplasty
    • Yamaguchi, M., Akisue, T., Bauer, T. W., and Hashimoto, Y. The spatial location of impingement in total hip arthroplasty. J. Arthroplasty, 2000, 15, 305-313.
    • (2000) J. Arthroplasty , vol.15 , pp. 305-313
    • Yamaguchi, M.1    Akisue, T.2    Bauer, T.W.3    Hashimoto, Y.4
  • 11
    • 0141952549 scopus 로고    scopus 로고
    • Impingement in total hip arthroplasty: A study of retrieved acetabular components
    • Shon, W. Y., Wright, T. M., and Baldini, T. Impingement in total hip arthroplasty: a study of retrieved acetabular components. Trans. 47th Orthop. Res. Soc., 2001, p. 1070.
    • (2001) Trans. 47th Orthop. Res. Soc. , pp. 1070
    • Shon, W.Y.1    Wright, T.M.2    Baldini, T.3
  • 13
    • 0035216823 scopus 로고    scopus 로고
    • Stem design and dislocation after revision total hip arthroplasty: Clinical results and computer modeling
    • Barrack, R. L., Butler, R. A., Laster, D. R., and Andrews, P. Stem design and dislocation after revision total hip arthroplasty: clinical results and computer modeling. J. Arthroplasty, 2001, 16(8), Suppl. 1, 8-12.
    • (2001) J. Arthroplasty , vol.16 , Issue.8 SUPPL. 1 , pp. 8-12
    • Barrack, R.L.1    Butler, R.A.2    Laster, D.R.3    Andrews, P.4
  • 14
    • 0030817525 scopus 로고    scopus 로고
    • Effect of the elevated-rim acetabular liner on loosening after total hip arthroplasty
    • Cobb, T. K., Morrey, B. F., and Iistrup, D. M. Effect of the elevated-rim acetabular liner on loosening after total hip arthroplasty. J. Bone Jt Surg., 1997, 79A(9), 1361-1364.
    • (1997) J. Bone Jt Surg. , vol.79 A , Issue.9 , pp. 1361-1364
    • Cobb, T.K.1    Morrey, B.F.2    Iistrup, D.M.3
  • 16
    • 0033819163 scopus 로고    scopus 로고
    • The effect of femoral component head size on posterior dislocation of the artificial hip joint
    • Bartz, R. L., Nobel, P. C., Kadakia, N. R., and Tullos, H. S. The effect of femoral component head size on posterior dislocation of the artificial hip joint. J. Bone Jt. Surg., 2000, 82A(9), 1300-1307.
    • (2000) J. Bone Jt. Surg. , vol.82 A , Issue.9 , pp. 1300-1307
    • Bartz, R.L.1    Nobel, P.C.2    Kadakia, N.R.3    Tullos, H.S.4
  • 17
    • 0036221960 scopus 로고    scopus 로고
    • Independent contribution of elevated-rim acetabular liner and femoral head size to the stability of total hip implants
    • Sultan, P. G., Tan, V., Lai, M., and Garino, J. P. Independent contribution of elevated-rim acetabular liner and femoral head size to the stability of total hip implants. J. Arthroplasty, 2002, 17(3), 289-292.
    • (2002) J. Arthroplasty , vol.17 , Issue.3 , pp. 289-292
    • Sultan, P.G.1    Tan, V.2    Lai, M.3    Garino, J.P.4
  • 18
    • 0027249089 scopus 로고
    • Dislocation following THA: Comparison of two acetabular component designs
    • Brien, W. W., Salvati, E. A., Wright, T. M., and Burstein, A. H. Dislocation following THA: comparison of two acetabular component designs. Orthopedics, 1993, 16(8), 869-872.
    • (1993) Orthopedics , vol.16 , Issue.8 , pp. 869-872
    • Brien, W.W.1    Salvati, E.A.2    Wright, T.M.3    Burstein, A.H.4
  • 19
    • 0035216918 scopus 로고    scopus 로고
    • A novel constrained acetabular liner design with increased range of motion
    • Burroughs, B. R., Golladay, G. J., Hallstrom, B., and Harris, W. H. A novel constrained acetabular liner design with increased range of motion. J. Arthroplasty, 2001, 16(8), Suppl. 1, 31-36.
    • (2001) J. Arthroplasty , vol.16 , Issue.8 SUPPL. 1 , pp. 31-36
    • Burroughs, B.R.1    Golladay, G.J.2    Hallstrom, B.3    Harris, W.H.4
  • 20
    • 0032701727 scopus 로고    scopus 로고
    • Finite element analysis of a novel design approach to resisting total hip dislocation
    • Scifert, C. F., Brown, T. D., and Lipman, J. D. Finite element analysis of a novel design approach to resisting total hip dislocation. Clin. Biomechanics (Bristol, Avon), 1999, 14(10), 697-703.
    • (1999) Clin. Biomechanics (Bristol, Avon) , vol.14 , Issue.10 , pp. 697-703
    • Scifert, C.F.1    Brown, T.D.2    Lipman, J.D.3
  • 23
    • 0036796295 scopus 로고    scopus 로고
    • Posterior transosseous capsulotendinous repair in total hip arthroplasty: A cadaver study
    • Sioen, W., Simon, J. P., Labey, L., and Van Audekercke, R. Posterior transosseous capsulotendinous repair in total hip arthroplasty: a cadaver study. J. Bone Jt Surg., 2002, 84A(10), 1793-1798.
    • (2002) J. Bone Jt Surg. , vol.84 A , Issue.10 , pp. 1793-1798
    • Sioen, W.1    Simon, J.P.2    Labey, L.3    Van Audekercke, R.4
  • 24
    • 0037591620 scopus 로고    scopus 로고
    • Constrained acetabular cups: A cadaveric biomechanical evaluation
    • Clyburn, T. A., Weitz-Marshall, A., and Ambrose, C. G. Constrained acetabular cups: a cadaveric biomechanical evaluation. J. Arthroplasty, 2003, 18(4), 466-470.
    • (2003) J. Arthroplasty , vol.18 , Issue.4 , pp. 466-470
    • Clyburn, T.A.1    Weitz-Marshall, A.2    Ambrose, C.G.3
  • 25
    • 0025282813 scopus 로고
    • Dislocation of total hip replacements. A comparative study of standard, long posterior wall and augmented acetabular components
    • Nicholas, R. M., Orr, J. E, Mollan, R. A., Calderwood, J. W., Nixon, J. R., and Watson, P. Dislocation of total hip replacements. A comparative study of standard, long posterior wall and augmented acetabular components. J. Bone Jt Surg., 1990, 72B(3), 418-22.
    • (1990) J. Bone Jt Surg. , vol.72 B , Issue.3 , pp. 418-422
    • Nicholas, R.M.1    Orr, J.E.2    Mollan, R.A.3    Calderwood, J.W.4    Nixon, J.R.5    Watson, P.6
  • 27
    • 0034012520 scopus 로고    scopus 로고
    • The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios
    • D'Lima, D. D., Urquhart, A. G., Buehler, K. O., Walker, R. H., and Colwell, C. W. Jr. The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J. Bone Jt Surg., 2000, 82A(3), 315-321.
    • (2000) J. Bone Jt Surg. , vol.82 A , Issue.3 , pp. 315-321
    • D'Lima, D.D.1    Urquhart, A.G.2    Buehler, K.O.3    Walker, R.H.4    Colwell Jr., C.W.5
  • 28
    • 0027977769 scopus 로고
    • Wear debris from bipolar femoral neck-cup impingement. A cause of femoral stem loosening
    • Messieh, M., Mattingly, D. A., Turner, R. H., Scott, R., Fox, J., and Slater, J. Wear debris from bipolar femoral neck-cup impingement. A cause of femoral stem loosening. J. Arthroplasty, 1994, 9(1), 89-93.
    • (1994) J. Arthroplasty , vol.9 , Issue.1 , pp. 89-93
    • Messieh, M.1    Mattingly, D.A.2    Turner, R.H.3    Scott, R.4    Fox, J.5    Slater, J.6
  • 29
    • 33646018901 scopus 로고    scopus 로고
    • Reliable acetabular cup orientation with a new gravity-assisted guidance system
    • Echeverri, S., Leyvraz, P. F., Zambelli, P. Y., and Jolles, B. M. Reliable acetabular cup orientation with a new gravity-assisted guidance system. J. Arthroplasty, 2006, 21(3), 413-419.
    • (2006) J. Arthroplasty , vol.21 , Issue.3 , pp. 413-419
    • Echeverri, S.1    Leyvraz, P.F.2    Zambelli, P.Y.3    Jolles, B.M.4
  • 30
    • 0019057926 scopus 로고
    • Dislocation in total hip arthroplasties
    • Fackler, C. D. and Poss, R. Dislocation in total hip arthroplasties. Clin. Orthop. Rel. Res., 1980, (151), 169-178.
    • (1980) Clin. Orthop. Rel. Res. , Issue.151 , pp. 169-178
    • Fackler, C.D.1    Poss, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.