메뉴 건너뛰기




Volumn 75, Issue 2, 2007, Pages 93-95

Copper T 380A IUD and magnetic resonance imaging

Author keywords

Contraception; Copper intrauterine device; Imaging; Magnetic resonance; Safety

Indexed keywords

COPPER INTRAUTERINE DEVICE;

EID: 33846271417     PISSN: 00107824     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.contraception.2006.07.016     Document Type: Article
Times cited : (18)

References (8)
  • 1
    • 0030986104 scopus 로고    scopus 로고
    • Lack of interaction between magnetic resonance imaging and the Copper-T380A IUD
    • Pasquale A.S., Russer T.J., Foldesy R., and Mezrich R.S. Lack of interaction between magnetic resonance imaging and the Copper-T380A IUD. Contraception 55 (1997) 169-173
    • (1997) Contraception , vol.55 , pp. 169-173
    • Pasquale, A.S.1    Russer, T.J.2    Foldesy, R.3    Mezrich, R.S.4
  • 2
    • 0023124231 scopus 로고
    • Intrauterine contraceptive devices: MR imaging
    • Mark A.S., and Hricak H. Intrauterine contraceptive devices: MR imaging. Radiology 162 (1987) 311-314
    • (1987) Radiology , vol.162 , pp. 311-314
    • Mark, A.S.1    Hricak, H.2
  • 3
    • 0029688017 scopus 로고    scopus 로고
    • Safety of intrauterine devices during MR imaging
    • Hess T., Stepanow B., and Knopp M.V. Safety of intrauterine devices during MR imaging. Eur Radiol 6 (1996) 66-68
    • (1996) Eur Radiol , vol.6 , pp. 66-68
    • Hess, T.1    Stepanow, B.2    Knopp, M.V.3
  • 4
    • 0036099287 scopus 로고    scopus 로고
    • New metallic implant used for permanent contraception in women: evaluation of MR safety
    • Shellock F.G. New metallic implant used for permanent contraception in women: evaluation of MR safety. AJR Am J Roentgenol 178 (2002) 1513-1516
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 1513-1516
    • Shellock, F.G.1
  • 6
    • 23644434337 scopus 로고    scopus 로고
    • Standard test method for measurement of magnetically induced displacement force on passive implants in the magnetic resonance environment
    • Emergency Medical Services, West Conshohocken (PA)
    • American Society for Testing and Materials (ASTM) Designation: F 2052. Standard test method for measurement of magnetically induced displacement force on passive implants in the magnetic resonance environment. Annual Book of ASTM Standards, Section 13, Medical Devices and Services, Volume 13.01 Medical Devices (2002), Emergency Medical Services, West Conshohocken (PA) 1576-1580
    • (2002) Annual Book of ASTM Standards, Section 13, Medical Devices and Services, Volume 13.01 Medical Devices , pp. 1576-1580
  • 7
    • 0034875055 scopus 로고    scopus 로고
    • Metallic and neurosurgical implants: evaluation of magnetic field interactions, heating, and artifacts at 1.5-Tesla
    • Shellock F.G. Metallic and neurosurgical implants: evaluation of magnetic field interactions, heating, and artifacts at 1.5-Tesla. J Magn Reson Imaging 14 (2001) 295-299
    • (2001) J Magn Reson Imaging , vol.14 , pp. 295-299
    • Shellock, F.G.1
  • 8
    • 33846300409 scopus 로고    scopus 로고
    • A standard test method for measurement of radio frequency induced heating near passive implants during magnetic resonance imaging
    • Emergency Medical Services, West Conshohocken (PA)
    • American Society for Testing and Materials (ASTM) Designation: F2182-02. A standard test method for measurement of radio frequency induced heating near passive implants during magnetic resonance imaging. Annual Book of ASTM Standards, Section 13, Medical Devices and Services, Volume 13.01 Medical Devices (2003), Emergency Medical Services, West Conshohocken (PA)
    • (2003) Annual Book of ASTM Standards, Section 13, Medical Devices and Services, Volume 13.01 Medical Devices


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.