Volumn 10, Issue 4, 2006, Pages 257-259

Guide-wire embolism during subclavian vein catheterization by Seldinger technique

Author keywords

Central venous catheterization; Complications; Guide wire embolism; Seldinger technique

Indexed keywords

ADULT; ARTICLE; CANNULATION; CASE REPORT; DEVICE REMOVAL; FEMALE; FLUOROSCOPY; GUIDE WIRE; HUMAN; ILIAC VEIN; INFERIOR CAVA VEIN; INTENSIVE CARE UNIT; SUBCLAVIAN VEIN CATHETER; TECHNIQUE; THORAX RADIOGRAPHY; TREATMENT OUTCOME; VEIN EMBOLISM; VIRUS ENCEPHALITIS;

EID: 33846240466     PISSN: 09725229     EISSN: None     Source Type: Journal    
DOI: 10.4103/0972-5229.29846     Document Type: Article
Times cited : (7)

References (12)
  • 2
    • 0029086583 scopus 로고
    • Insertion of long term central venous catheter: Time for a new look
    • Adam A. Insertion of long term central venous catheter: Time for a new look. BMJ 1995;311:341-2.
    • (1995) BMJ , vol.311 , pp. 341-342
    • Adam, A.1
  • 5
    • 0027248143 scopus 로고
    • 14-year follow-up of central embolization by a guide wire
    • Reynen K. 14-year follow-up of central embolization by a guide wire. N Engl J Med 1993;329:970-1.
    • (1993) N Engl J Med , vol.329 , pp. 970-971
    • Reynen, K.1
  • 6
    • 0035827890 scopus 로고    scopus 로고
    • Complications of femoral and subclavian venous catheterization in critically ill patients
    • Merrer J, Jonghe BD, Golliot F, Lefrant JY, Raffy B, Barre E, et al. Complications of femoral and subclavian venous catheterization in critically ill patients. JAMA 2001;286:700-7.
    • (2001) JAMA , vol.286 , pp. 700-707
    • Merrer, J.1    Jonghe, B.D.2    Golliot, F.3    Lefrant, J.Y.4    Raffy, B.5    Barre, E.6
  • 7
    • 1242281613 scopus 로고    scopus 로고
    • Central line complications from the ASA Closed Claim Project: An Update
    • and
    • Browdle TA. Central line complications from the ASA Closed Claim Project: An Update. ASA Newsl 2002;66:11-2 and 25.
    • (2002) ASA Newsl , vol.66
    • Browdle, T.A.1
  • 10
    • 0033974729 scopus 로고    scopus 로고
    • How much guidewire is too much? Direct measurement of the distance from subclavian and internal jugular vein access sites to the superior vena cava-atrial junction during central venous catheter placement
    • Andrews RT, Bova DA, Venbrux AC. How much guidewire is too much? Direct measurement of the distance from subclavian and internal jugular vein access sites to the superior vena cava-atrial junction during central venous catheter placement. Crit Care Med 2000;28:138-42.
    • (2000) Crit Care Med , vol.28 , pp. 138-142
    • Andrews, R.T.1    Bova, D.A.2    Venbrux, A.C.3