메뉴 건너뛰기




Volumn 26, Issue 1, 2007, Pages 15-30

Tracking myocardial motion from cine DENSE images using spatiotemporal phase unwrapping and temporal fitting

Author keywords

Cardiac magnetic resonance imaging (MRI); DENSE; LV function; Myocardial tagging; Phase unwrapping

Indexed keywords

ALGORITHMS; CARDIOLOGY; HISTOLOGY; IMAGE QUALITY; MAGNETIC RESONANCE IMAGING; MEDICAL IMAGING;

EID: 33846236285     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2006.884215     Document Type: Article
Times cited : (187)

References (48)
  • 1
    • 0016824666 scopus 로고
    • Measurements of midwall dynamics in intact man by radiography of surgically implanted markers
    • N. Ingels, G. Daughters, and E. Stinson, "Measurements of midwall dynamics in intact man by radiography of surgically implanted markers," Circulation, vol. 52, pp. 859-867, 1975.
    • (1975) Circulation , vol.52 , pp. 859-867
    • Ingels, N.1    Daughters, G.2    Stinson, E.3
  • 2
    • 0023882471 scopus 로고
    • A technique for measuring regional two dimensional finite strains in canine left ventricle
    • F. Villarreal, L. Waldman, and W. Lew, "A technique for measuring regional two dimensional finite strains in canine left ventricle," Circulation Res., vol. 62, pp. 711-721, 1988.
    • (1988) Circulation Res , vol.62 , pp. 711-721
    • Villarreal, F.1    Waldman, L.2    Lew, W.3
  • 4
    • 0026783003 scopus 로고
    • Three-dimensional motion and deformation of the heart wall: Estimation with spatial modulation of magnetization - A model-based approach
    • A. A. Young and L. Axel, "Three-dimensional motion and deformation of the heart wall: Estimation with spatial modulation of magnetization - A model-based approach," Radiology, vol. 185, pp. 241-247, 1992.
    • (1992) Radiology , vol.185 , pp. 241-247
    • Young, A.A.1    Axel, L.2
  • 5
    • 0024318208 scopus 로고
    • MR imaging of motion with spatial modulation of magnetization
    • L. Axel and L. Dougherty, "MR imaging of motion with spatial modulation of magnetization," Radiology, vol. 171, pp. 841-845, 1989.
    • (1989) Radiology , vol.171 , pp. 841-845
    • Axel, L.1    Dougherty, L.2
  • 6
    • 0023737101 scopus 로고
    • Human heart: Tagging with MR imaging - A method for noninvasive assessment of myocardial motion
    • E. A. Zerhouni, D. M. Parish, W. J. Rogers, A. Yang, and E. P. Shapiro, "Human heart: Tagging with MR imaging - A method for noninvasive assessment of myocardial motion," Radiology, vol. 169, no. 1, pp. 59-63, 1988.
    • (1988) Radiology , vol.169 , Issue.1 , pp. 59-63
    • Zerhouni, E.A.1    Parish, D.M.2    Rogers, W.J.3    Yang, A.4    Shapiro, E.P.5
  • 7
    • 0021235637 scopus 로고
    • Direct cardiac MNR imaging of heart wall and blood flow velocity
    • P. Van Dijk, "Direct cardiac MNR imaging of heart wall and blood flow velocity," J. Comput. Assist. Tomogr., vol. 8, no. 3, pp. 429-436, 1984.
    • (1984) J. Comput. Assist. Tomogr , vol.8 , Issue.3 , pp. 429-436
    • Van Dijk, P.1
  • 8
    • 0021282475 scopus 로고
    • Measurement of flow with NMR imaging using gradient pulse and phase difference technique
    • D. Bryant, J. Payne, D. Firmin, and D. Longmore, "Measurement of flow with NMR imaging using gradient pulse and phase difference technique," J. Comput. Assist. Tomogr., vol. 8, no. 4, pp. 588-593, 1984.
    • (1984) J. Comput. Assist. Tomogr , vol.8 , Issue.4 , pp. 588-593
    • Bryant, D.1    Payne, J.2    Firmin, D.3    Longmore, D.4
  • 9
    • 0033093565 scopus 로고    scopus 로고
    • DENSE: Displacement encoding with stimulated echoes in cardiac functional MRI
    • A. Aletras, S. Ding, R. Balaban, and H. Wen, "DENSE: Displacement encoding with stimulated echoes in cardiac functional MRI," J. Magn. Reson., vol. 137, pp. 247-252, 1999.
    • (1999) J. Magn. Reson , vol.137 , pp. 247-252
    • Aletras, A.1    Ding, S.2    Balaban, R.3    Wen, H.4
  • 10
    • 0033623972 scopus 로고    scopus 로고
    • Imaging heart motion using harmonic phase MRI
    • Mar
    • N. F. Osman, E. R. McVeigh, and J. L. Prince, "Imaging heart motion using harmonic phase MRI," IEEE Trans. Med. Imag., vol. 19, no. 3, pp. 186-202, Mar. 2000.
    • (2000) IEEE Trans. Med. Imag , vol.19 , Issue.3 , pp. 186-202
    • Osman, N.F.1    McVeigh, E.R.2    Prince, J.L.3
  • 11
    • 33846195927 scopus 로고    scopus 로고
    • Developing a navigator-guided approach to non-breathold multiphase cardiac strain maps using DENSE
    • V. M. Pai and H. Wen, "Developing a navigator-guided approach to non-breathold multiphase cardiac strain maps using DENSE," J. Cardiovasc. Magn. Reson., vol. 5, no. 1, pp. 239-242, 2003.
    • (2003) J. Cardiovasc. Magn. Reson , vol.5 , Issue.1 , pp. 239-242
    • Pai, V.M.1    Wen, H.2
  • 12
    • 1342329974 scopus 로고    scopus 로고
    • Myocardial tissue tracking with two-dimensional cine displacement-encoded MR imaging: Development and initial evaluation
    • D. Kim, W. Gilson, C. Kramer, and F. Epstein, "Myocardial tissue tracking with two-dimensional cine displacement-encoded MR imaging: Development and initial evaluation," Radiology, vol. 230, pp. 862-871, 2004.
    • (2004) Radiology , vol.230 , pp. 862-871
    • Kim, D.1    Gilson, W.2    Kramer, C.3    Epstein, F.4
  • 13
    • 3142565131 scopus 로고    scopus 로고
    • Meta-DENSE complex acquisition for reduced intravoxel dephasing
    • A. H. Aletras and A. E. Arai, "Meta-DENSE complex acquisition for reduced intravoxel dephasing," J. Magn. Reson., vol. 196, pp. 246-249, 1999.
    • (1999) J. Magn. Reson , vol.196 , pp. 246-249
    • Aletras, A.H.1    Arai, A.E.2
  • 14
    • 0033185649 scopus 로고    scopus 로고
    • High-resolution strain analysis of the human heart with fast-DENSE
    • A. H. Aletras, R. S. Balaban, and H. Wen, "High-resolution strain analysis of the human heart with fast-DENSE," J. Magn. Reson., vol. 140, pp. 41-57, 1999.
    • (1999) J. Magn. Reson , vol.140 , pp. 41-57
    • Aletras, A.H.1    Balaban, R.S.2    Wen, H.3
  • 15
    • 33750609509 scopus 로고    scopus 로고
    • Selective suppression of artifact-generating echoes in cine DENSE using through-plane dephasing
    • X. Zhong, B. S. Spottiswoode, E. A. Cowart, W. D. Gilson, and F. H. Epstein, "Selective suppression of artifact-generating echoes in cine DENSE using through-plane dephasing," Magn. Reson. Med., vol. 56, no. 5, pp. 1126-1131, 2006.
    • (2006) Magn. Reson. Med , vol.56 , Issue.5 , pp. 1126-1131
    • Zhong, X.1    Spottiswoode, B.S.2    Cowart, E.A.3    Gilson, W.D.4    Epstein, F.H.5
  • 17
    • 0000186699 scopus 로고
    • Analysis of the phase unwrapping problem
    • K. Itoh, "Analysis of the phase unwrapping problem," Appl. Opt., vol. 21, no. 14, p. 2470, 1980.
    • (1980) Appl. Opt , vol.21 , Issue.14 , pp. 2470
    • Itoh, K.1
  • 19
    • 4744363620 scopus 로고    scopus 로고
    • Displacement-encoded cardiac MRI using cosine and sine modulation to eliminate (CANSEL) artifact-generating echoes
    • F. H. Epstein and W. D. Gilson, "Displacement-encoded cardiac MRI using cosine and sine modulation to eliminate (CANSEL) artifact-generating echoes," Magn. Reson. Med., vol. 52, no. 4, pp. 774-781, 2004.
    • (2004) Magn. Reson. Med , vol.52 , Issue.4 , pp. 774-781
    • Epstein, F.H.1    Gilson, W.D.2
  • 23
    • 0030140095 scopus 로고    scopus 로고
    • Dynamic range extension of cine velocity measurements using motion-registered spatiotemporal phase unwrapping
    • G. Z. Yang, P. Burger, P. J. Kilner, S. P. Karwatowski, and D. N. Firmin, "Dynamic range extension of cine velocity measurements using motion-registered spatiotemporal phase unwrapping," J. Magn. Reson. Imag., vol. 6, pp. 495-502, 1996.
    • (1996) J. Magn. Reson. Imag , vol.6 , pp. 495-502
    • Yang, G.Z.1    Burger, P.2    Kilner, P.J.3    Karwatowski, S.P.4    Firmin, D.N.5
  • 24
    • 0024045217 scopus 로고
    • Satellite radar interferometry: Two-dimensional phase unwrapping
    • R. M. Goldstein, H. A. Zebken, and C. L. Werner, "Satellite radar interferometry: Two-dimensional phase unwrapping," Radio Sci., vol. 23, no. 4, pp. 713-720, 1988.
    • (1988) Radio Sci , vol.23 , Issue.4 , pp. 713-720
    • Goldstein, R.M.1    Zebken, H.A.2    Werner, C.L.3
  • 25
    • 84975562125 scopus 로고
    • Unwrapping noisy phase maps by use of a minimum-cost-matching algorithm
    • J. R. Buckland, J. M. Huntley, and S. R. E. Turner, "Unwrapping noisy phase maps by use of a minimum-cost-matching algorithm," Appl. Opt., vol. 34, no. 23, pp. 5100-5108, 1995.
    • (1995) Appl. Opt , vol.34 , Issue.23 , pp. 5100-5108
    • Buckland, J.R.1    Huntley, J.M.2    Turner, S.R.E.3
  • 26
    • 0141617512 scopus 로고    scopus 로고
    • Importance of k-space trajectory in echo-planar myocardial tagging at rest and during dobutamine stress
    • D. Kim, C. M. Bove, C. M. Kramer, and F. H. Epstein, "Importance of k-space trajectory in echo-planar myocardial tagging at rest and during dobutamine stress," Magn. Reson. Med., vol. 50, pp. 813-820, 2003.
    • (2003) Magn. Reson. Med , vol.50 , pp. 813-820
    • Kim, D.1    Bove, C.M.2    Kramer, C.M.3    Epstein, F.H.4
  • 27
    • 0028953895 scopus 로고
    • Improved ejection fraction and flow velocity estimates with use of view sharing and uniform repetition time excitation with fast cardiac techniques
    • T. K. F. Foo, M. A. Bernstein, A. M. Aisen, R. J. Hernandez, B. D. Collick, and T. Bernstein, "Improved ejection fraction and flow velocity estimates with use of view sharing and uniform repetition time excitation with fast cardiac techniques," Radiology, vol. 195, pp. 471-478, 1995.
    • (1995) Radiology , vol.195 , pp. 471-478
    • Foo, T.K.F.1    Bernstein, M.A.2    Aisen, A.M.3    Hernandez, R.J.4    Collick, B.D.5    Bernstein, T.6
  • 29
    • 0029040249 scopus 로고
    • Limitations of stimulated echo acquisition mode (STEAM) techniques in cardiac applications
    • S. E. Fischer, M. Stuber, M. B. Scheidegger, and P. Boesiger, "Limitations of stimulated echo acquisition mode (STEAM) techniques in cardiac applications," Magn. Reson. Med., vol. 34, pp. 80-91, 1995.
    • (1995) Magn. Reson. Med , vol.34 , pp. 80-91
    • Fischer, S.E.1    Stuber, M.2    Scheidegger, M.B.3    Boesiger, P.4
  • 30
    • 0036338395 scopus 로고    scopus 로고
    • New robust 3-D phase unwrapping algorithms: Application to magnetic field mapping and undistorted echoplanar images
    • R. Cusack and N. Papadakis, "New robust 3-D phase unwrapping algorithms: Application to magnetic field mapping and undistorted echoplanar images," NeuroImage, vol. 16, pp. 754-764, 2002.
    • (2002) NeuroImage , vol.16 , pp. 754-764
    • Cusack, R.1    Papadakis, N.2
  • 31
    • 0037225733 scopus 로고    scopus 로고
    • Fast, automated N-dimensional phase-unwrapping algorithm
    • M. Jenkinson, "Fast, automated N-dimensional phase-unwrapping algorithm," Magn. Reson. Med., vol. 48, pp. 193-197, 2003.
    • (2003) Magn. Reson. Med , vol.48 , pp. 193-197
    • Jenkinson, M.1
  • 32
    • 0011769353 scopus 로고    scopus 로고
    • Three-dimensional noise-immune phase unwrapping algorithm
    • J. M. Huntley, "Three-dimensional noise-immune phase unwrapping algorithm," Appl. Opt., vol. 40, no. 23, pp. 3901-3908, 2001.
    • (2001) Appl. Opt , vol.40 , Issue.23 , pp. 3901-3908
    • Huntley, J.M.1
  • 33
    • 33846189459 scopus 로고    scopus 로고
    • Extending the dynamic range of phase contrast magnetic resonance velocity imaging using advanced higher-dimensional phase unwrapping algorithms
    • M. F. Salfity, J. M. Huntley, M. J. Graves, O. Marklund, R. Cusack, and D. A. Beauregard, "Extending the dynamic range of phase contrast magnetic resonance velocity imaging using advanced higher-dimensional phase unwrapping algorithms," J. Roy. Soc. Interface, vol. 5, 2005.
    • (2005) J. Roy. Soc. Interface , vol.5
    • Salfity, M.F.1    Huntley, J.M.2    Graves, M.J.3    Marklund, O.4    Cusack, R.5    Beauregard, D.A.6
  • 34
    • 0028203412 scopus 로고
    • Tagged MR imaging in a deformable phantom: Photographic validation
    • C. C. Moore, S. B. Reeder, and E. R. McVeigh, "Tagged MR imaging in a deformable phantom: Photographic validation," Radiology, vol. 190, pp. 765-769, 1994.
    • (1994) Radiology , vol.190 , pp. 765-769
    • Moore, C.C.1    Reeder, S.B.2    McVeigh, E.R.3
  • 35
    • 0025883598 scopus 로고
    • Noninvasive measurement of transmural gradients in myocardial strain with MR imaging
    • E. R. McVeigh and E. A. Zerhouni, "Noninvasive measurement of transmural gradients in myocardial strain with MR imaging," Radiology, vol. 180, pp. 677-683, 1991.
    • (1991) Radiology , vol.180 , pp. 677-683
    • McVeigh, E.R.1    Zerhouni, E.A.2
  • 36
    • 0028396731 scopus 로고
    • Optimization of tag thickness for measuring position with magnetic resonance imaging
    • Mar
    • E. Altar and E. R. McVeigh, "Optimization of tag thickness for measuring position with magnetic resonance imaging," IEEE Trans. Med. Imag., vol. 13, no. 1, pp. 152-160, Mar. 1994.
    • (1994) IEEE Trans. Med. Imag , vol.13 , Issue.1 , pp. 152-160
    • Altar, E.1    McVeigh, E.R.2
  • 37
    • 0029375805 scopus 로고
    • Tracking and finite element analysis of stripe deformation in magnetic resonance tagging
    • Sep
    • A. A. Young, D. L. Kraitchman, L. Dougherty, and L. Axel, "Tracking and finite element analysis of stripe deformation in magnetic resonance tagging," IEEE Trans. Med. Imag., vol. 14, no. 3, pp. 413-421, Sep. 1995.
    • (1995) IEEE Trans. Med. Imag , vol.14 , Issue.3 , pp. 413-421
    • Young, A.A.1    Kraitchman, D.L.2    Dougherty, L.3    Axel, L.4
  • 38
    • 0032589159 scopus 로고    scopus 로고
    • Validation of an optical flow method for tag displacement estimation
    • Apr
    • L. Dougherty, J. C. Asmuth, A. S. A. S. Blom, L. Axel, and R. Kumar, "Validation of an optical flow method for tag displacement estimation," IEEE Trans. Med. Imag., vol. 18, no. 4, pp. 359-363, Apr. 1999.
    • (1999) IEEE Trans. Med. Imag , vol.18 , Issue.4 , pp. 359-363
    • Dougherty, L.1    Asmuth, J.C.2    Blom, A.S.A.S.3    Axel, L.4    Kumar, R.5
  • 40
    • 0033921218 scopus 로고    scopus 로고
    • Detailed motion analysis of the left ventricular myocardium using an MR tagging method with a dense grid
    • S. Urayama, T. Matsuda, N. Sugimoto, S. Mizuta, N. Yamada, and C. Uyama, "Detailed motion analysis of the left ventricular myocardium using an MR tagging method with a dense grid," Magn. Reson. Med., vol. 44, pp. 73-82, 2000.
    • (2000) Magn. Reson. Med , vol.44 , pp. 73-82
    • Urayama, S.1    Matsuda, T.2    Sugimoto, N.3    Mizuta, S.4    Yamada, N.5    Uyama, C.6
  • 41
    • 0029301143 scopus 로고
    • Tracking of cyclic motion with phase-contrast MR velocity data
    • N. J. Pelc, M. Drangova, and L. R. Pelc, "Tracking of cyclic motion with phase-contrast MR velocity data," J. Magn. Reson. Imag., vol. 5, pp. 339-345, 1995.
    • (1995) J. Magn. Reson. Imag , vol.5 , pp. 339-345
    • Pelc, N.J.1    Drangova, M.2    Pelc, L.R.3
  • 42
    • 0031771410 scopus 로고    scopus 로고
    • In vitro verification of myocardial motion tracking from phase-contrast velocity data
    • M. Drangova, Y. Zhu, B. Bowman, and N. J. Pelc, "In vitro verification of myocardial motion tracking from phase-contrast velocity data," Magn. Reson. Imag., vol. 16, no. 8, pp. 863-870, 1998.
    • (1998) Magn. Reson. Imag , vol.16 , Issue.8 , pp. 863-870
    • Drangova, M.1    Zhu, Y.2    Bowman, B.3    Pelc, N.J.4
  • 43
    • 0028239979 scopus 로고
    • Development and evaluation of tracking algorithms for cardiac wall motion analysis using phase velocity MR imaging
    • R. T. Constable, K. M. Rath, A. J. Sinusas, and J. C. Gore, "Development and evaluation of tracking algorithms for cardiac wall motion analysis using phase velocity MR imaging," Magn. Reson. Med., vol. 32, pp. 33-42, 1994.
    • (1994) Magn. Reson. Med , vol.32 , pp. 33-42
    • Constable, R.T.1    Rath, K.M.2    Sinusas, A.J.3    Gore, J.C.4
  • 44
    • 0029881362 scopus 로고    scopus 로고
    • Fourier tracking of myocardial motion using cine-PC data
    • Y. Zhu, M. Drangova, and N. J. Pelc, "Fourier tracking of myocardial motion using cine-PC data," Magn. Reson. Med., vol. 35, pp. 471-480, 1996.
    • (1996) Magn. Reson. Med , vol.35 , pp. 471-480
    • Zhu, Y.1    Drangova, M.2    Pelc, N.J.3
  • 45
    • 0033956547 scopus 로고    scopus 로고
    • Three-dimensional systolic patterns in the normal human left ventricle: Characterization with tagged MR imaging
    • C. C. Moore, C. H. Lugo-Olivieri, E. R. McVeigh, and E. A. Zerhouni, "Three-dimensional systolic patterns in the normal human left ventricle: Characterization with tagged MR imaging," Radiology, vol. 214, pp. 453-466, 2000.
    • (2000) Radiology , vol.214 , pp. 453-466
    • Moore, C.C.1    Lugo-Olivieri, C.H.2    McVeigh, E.R.3    Zerhouni, E.A.4
  • 47
    • 0043268055 scopus 로고    scopus 로고
    • Myocardial kinematics from tagged MRI based on a 4-D B-spline model
    • Aug
    • N. J. Tustison, V. G. Dávila-Román, and A. A. Amini, "Myocardial kinematics from tagged MRI based on a 4-D B-spline model," IEEE Trans. Biomed. Eng., vol. 50, no. 8, pp. 1038-1041, Aug. 2003.
    • (2003) IEEE Trans. Biomed. Eng , vol.50 , Issue.8 , pp. 1038-1041
    • Tustison, N.J.1    Dávila-Román, V.G.2    Amini, A.A.3
  • 48
    • 0032752454 scopus 로고    scopus 로고
    • Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging
    • N. F. Osman, W. S. Kerwin, E. R. McVeigh, and J. L. Prince, "Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging," Magn. Reson. Med., vol. 42, pp. 1048-1060, 1999.
    • (1999) Magn. Reson. Med , vol.42 , pp. 1048-1060
    • Osman, N.F.1    Kerwin, W.S.2    McVeigh, E.R.3    Prince, J.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.