메뉴 건너뛰기




Volumn 6380, Issue , 2006, Pages

Feasibility of monitoring patient motion with opposed stereo infrared cameras during supine medical imaging

Author keywords

Cameras; Correction; Infrared; Monitoring; Motion; Opposed

Indexed keywords

PROJECTION DATA; RECONSTRUCTION ARTIFACTS; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY (SPECT);

EID: 33846213948     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.686369     Document Type: Conference Paper
Times cited : (2)

References (14)
  • 1
    • 0027396030 scopus 로고
    • A quantitative assessment of patient motion and its effect on myocardial perfusion SPECT images
    • Feb
    • E. H. Botvinick, Y. Y. Zhu, W. J. O'Connell, and M. W. Dae, "A quantitative assessment of patient motion and its effect on myocardial perfusion SPECT images," J.Nucl.Med, vol. 34, no. 2, pp. 303-310, Feb. 1993.
    • (1993) J.Nucl.Med , vol.34 , Issue.2 , pp. 303-310
    • Botvinick, E.H.1    Zhu, Y.Y.2    O'Connell, W.J.3    Dae, M.W.4
  • 2
    • 0027427834 scopus 로고
    • Effect of motion on thallium-201 SPECT studies: A simulation and clinical study
    • Nov
    • F. M. Prigent, M. Hyun, D. S. Berman, and A. Rozanski, "Effect of motion on thallium-201 SPECT studies: a simulation and clinical study," J.Nucl.Med, vol. 34, no. 11, pp. 1845-1850, Nov.1993.
    • (1993) J.Nucl.Med , vol.34 , Issue.11 , pp. 1845-1850
    • Prigent, F.M.1    Hyun, M.2    Berman, D.S.3    Rozanski, A.4
  • 3
    • 0026655069 scopus 로고
    • Effect of patient motion on tomographic myocardial perfusion imaging
    • Aug
    • J. A. Cooper, P. H. Neumann, and B. K. McCandless, "Effect of patient motion on tomographic myocardial perfusion imaging," J.Nucl.Med, vol. 33, no. 8, pp. 1566-1571, Aug.1992.
    • (1992) J.Nucl.Med , vol.33 , Issue.8 , pp. 1566-1571
    • Cooper, J.A.1    Neumann, P.H.2    McCandless, B.K.3
  • 4
    • 33846265504 scopus 로고    scopus 로고
    • nd Annual Meeting, June 18-22, 2005, Toronto, Canada.
    • nd Annual Meeting, June 18-22, 2005, Toronto, Canada.
  • 5
    • 0033311379 scopus 로고    scopus 로고
    • A practical 3D tomographic method for correcting patient head motion in clinical SPECT
    • R. R. Fulton, S. Eberl, S. R. Meikle, B. F. Hutton, and M. Braun, "A practical 3D tomographic method for correcting patient head motion in clinical SPECT," IEEE Trans Nucl Sci, vol. 46, no. 3, pp. 667-672, 1999.
    • (1999) IEEE Trans Nucl Sci , vol.46 , Issue.3 , pp. 667-672
    • Fulton, R.R.1    Eberl, S.2    Meikle, S.R.3    Hutton, B.F.4    Braun, M.5
  • 6
    • 0033347806 scopus 로고    scopus 로고
    • Implementation and performance of an optical motion tracking system for high resolution brain PET imaging
    • B. J. Lopresti, A. Russo, W. F. Jones, T. Fisher, D. G. Crouch, D. E. Altenburger et al., "Implementation and performance of an optical motion tracking system for high resolution brain PET imaging," IEEE Trans Nucl Sci, vol. 46, no. 6, pp. 2059-2067, 1999.
    • (1999) IEEE Trans Nucl Sci , vol.46 , Issue.6 , pp. 2059-2067
    • Lopresti, B.J.1    Russo, A.2    Jones, W.F.3    Fisher, T.4    Crouch, D.G.5    Altenburger, D.E.6
  • 7
    • 0036464373 scopus 로고    scopus 로고
    • Correction for head movements in positron emission tomography using an optical motion-tracking system
    • R. R. Fulton, S. R. Meikle, S. Eberl, J. Pfeiffer, R. T. Constable, and M. J. Fulham, "Correction for head movements in positron emission tomography using an optical motion-tracking system.," IEEE Trans Nucl Sci, vol. 49, no. 1, pp. 116-123, 2002.
    • (2002) IEEE Trans Nucl Sci , vol.49 , Issue.1 , pp. 116-123
    • Fulton, R.R.1    Meikle, S.R.2    Eberl, S.3    Pfeiffer, J.4    Constable, R.T.5    Fulham, M.J.6
  • 9
    • 33846574140 scopus 로고    scopus 로고
    • Beach, Richard. D., Gifford, Howard C., Shazeeb, Salman, Bruyant, Philippe P., Feng, Bing, Gennert, Michael A., Nadella, Suman, King, Michael A., Stereo-Infrared Tracking to Monitor and Characterize Rigid-Body Motion and Respiration During Cardiac SPECT Imaging: Progress Towards Robust Clinical Utilization, In: Conference Record (May 11, 2005) - IEEE Nuclear Science Symposium, Medical Imaging Conference (NSS/MIC) October 23-29, 2005, Wyndham El Conquistador Hotel, Puerto Rico.
    • Beach, Richard. D., Gifford, Howard C., Shazeeb, Salman, Bruyant, Philippe P., Feng, Bing, Gennert, Michael A., Nadella, Suman, King, Michael A., Stereo-Infrared Tracking to Monitor and Characterize Rigid-Body Motion and Respiration During Cardiac SPECT Imaging: Progress Towards Robust Clinical Utilization, In: Conference Record (May 11, 2005) - IEEE Nuclear Science Symposium, Medical Imaging Conference (NSS/MIC) October 23-29, 2005, Wyndham El Conquistador Hotel, Puerto Rico.
  • 12
    • 33745341244 scopus 로고    scopus 로고
    • Use of Three-Dimensional Gaussian Interpolation in the Projector/Backprojector Pair for Compensation of the Known Rigid-Body Motion in SPECT
    • B. Feng, H. C. Gifford, R. D. Beach, G. Boening, M. A. Gennert, M. A. King, "Use of Three-Dimensional Gaussian Interpolation in the Projector/Backprojector Pair for Compensation of the Known Rigid-Body Motion in SPECT", IEEE Transactions on Medical Imaging, 25:838-844, 2006.
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , pp. 838-844
    • Feng, B.1    Gifford, H.C.2    Beach, R.D.3    Boening, G.4    Gennert, M.A.5    King, M.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.