메뉴 건너뛰기




Volumn 101, Issue 2, 2007, Pages 261-264

Evaluation of a transcutaneous carbon dioxide monitor ("TOSCA") in adult patients in routine respiratory practice

Author keywords

Adult; Non invasive monitoring; TOSCA; Transcutaneous carbon dioxide

Indexed keywords

CARBON DIOXIDE; OXYGEN;

EID: 33846176881     PISSN: 09546111     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.rmed.2006.05.011     Document Type: Article
Times cited : (47)

References (9)
  • 1
    • 0025261219 scopus 로고
    • Transcutaneous carbon dioxide monitoring
    • Rennie J.M. Transcutaneous carbon dioxide monitoring. Arch Dis Child 65 (1990) 345-346
    • (1990) Arch Dis Child , vol.65 , pp. 345-346
    • Rennie, J.M.1
  • 2
    • 0034743438 scopus 로고    scopus 로고
    • 2 and pulseoximetry monitors in newborns and infants after cardiac surgery
    • 2 and pulseoximetry monitors in newborns and infants after cardiac surgery. Anaesth Intensive Care 29 (2001) 260-265
    • (2001) Anaesth Intensive Care , vol.29 , pp. 260-265
    • Carter, B.G.1    Wiwczaruk, D.2    Hochman, M.3
  • 3
    • 0036140441 scopus 로고    scopus 로고
    • Combining transutaneous blood gas measurement and pulse oximetry
    • Eberhard P., Gisiger P.A., Gardaz J.P., and Spahn D.R. Combining transutaneous blood gas measurement and pulse oximetry. Anaesth Analg 94 (2002) S76-S80
    • (2002) Anaesth Analg , vol.94
    • Eberhard, P.1    Gisiger, P.A.2    Gardaz, J.P.3    Spahn, D.R.4
  • 4
    • 0032897070 scopus 로고    scopus 로고
    • Clinical investigation of a new combined pulse oximetry and carbon dioxide tension sensor in adult anaesthesia
    • Rohling R., and Biro P. Clinical investigation of a new combined pulse oximetry and carbon dioxide tension sensor in adult anaesthesia. J Clin Monit Comput 15 (1999) 23-27
    • (1999) J Clin Monit Comput , vol.15 , pp. 23-27
    • Rohling, R.1    Biro, P.2
  • 6
    • 33846157532 scopus 로고    scopus 로고
    • Evaluation of clinical accuracy of new transcutaneous carbon dioxide monitor TOSCA
    • Yamakage M., Satoh J.I., Saijoh H., and Namiki A. Evaluation of clinical accuracy of new transcutaneous carbon dioxide monitor TOSCA. Anaesthesiology 103 (2005) A838
    • (2005) Anaesthesiology , vol.103
    • Yamakage, M.1    Satoh, J.I.2    Saijoh, H.3    Namiki, A.4
  • 9
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet i (1986) 307-310
    • (1986) Lancet , vol.i , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.