메뉴 건너뛰기




Volumn 40, Issue 11, 2006, Pages 1290-1294

Numerical investigation on flow field and biocompatibility of an axial blood pump

Author keywords

Axial blood pump; Hemolysis index; Magnetic bearing; Numerical simulation

Indexed keywords

BIOCOMPATIBILITY; BLOOD; COMPUTER SIMULATION; CONTACTS (FLUID MECHANICS); DESIGN; ESTIMATION; MAGNETIC BEARINGS; NUMERICAL METHODS; PRESSURE; PROBABILITY; PROPELLERS; PUMPS; REYNOLDS NUMBER; ROTORS; SHEAR STRESS; SHELLS (STRUCTURES); SUSPENSIONS (FLUIDS); TUBES (COMPONENTS);

EID: 33846133295     PISSN: 0253987X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (15)
  • 1
    • 2342624694 scopus 로고    scopus 로고
    • Left ventricular assist devices as destination therapy
    • Mason V F, Konicki A J. Left ventricular assist devices as destination therapy[J]. AACN Clinical Issues, 2003, 14(4): 488-497.
    • (2003) AACN Clinical Issues , vol.14 , Issue.4 , pp. 488-497
    • Mason, V.F.1    Konicki, A.J.2
  • 2
    • 0034074215 scopus 로고    scopus 로고
    • Development and clinical application of the MicroMed DeBakey VAD
    • George P N, Deborah M, Suellen L. Development and clinical application of the MicroMed DeBakey VAD[J]. Current Opinion in Cardiology, 2000, 15(3): 166-171.
    • (2000) Current Opinion in Cardiology , vol.15 , Issue.3 , pp. 166-171
    • George, P.N.1    Deborah, M.2    Suellen, L.3
  • 3
    • 0035107143 scopus 로고    scopus 로고
    • Research and development of an implantable, axial-flow left ventricular assist device: The Jarvik 2000 heart
    • Frazier O H, Timothy J M, Jarvik R K. Research and development of an implantable, axial-flow left ventricular assist device: the Jarvik 2000 heart[J]. Ann Thora Surg, 2001, 71(3): S125-S132.
    • (2001) Ann Thora Surg , vol.71 , Issue.3
    • Frazier, O.H.1    Timothy, J.M.2    Jarvik, R.K.3
  • 4
    • 0036259166 scopus 로고    scopus 로고
    • Mini hemoreliable axial flow LVAD with magnetic bearings: Part 2. Design description
    • Goldowsky M P. Mini hemoreliable axial flow LVAD with magnetic bearings: part 2, design description[J]. ASAIO Journal, 2002, 48(1): 98-100.
    • (2002) ASAIO Journal , vol.48 , Issue.1 , pp. 98-100
    • Goldowsky, M.P.1
  • 5
    • 33751252529 scopus 로고    scopus 로고
    • Blood pump having a magnetically suspended rotor: United States patent, US 6447266 B2
    • Antaki J F, Paden B, Burgreen G. Blood pump having a magnetically suspended rotor: United States patent, US 6447266 B2[P]. 2002-09-10.
    • (2002)
    • Antaki, J.F.1    Paden, B.2    Burgreen, G.3
  • 6
    • 33751217670 scopus 로고    scopus 로고
    • Magnetically driven axial flow pump: United States patent, US 6527521 B2
    • Hiroyuki N. Magnetically driven axial flow pump: United States patent, US 6527521 B2[P]. 2003-03-04.
    • (2003)
    • Hiroyuki, N.1
  • 7
    • 0034838318 scopus 로고    scopus 로고
    • Computational fluid dynamics as a development tool for rotary blood pump
    • Burgreen G, Antaki J F, Wu Z J. Computational fluid dynamics as a development tool for rotary blood pump[J]. Artificial Organs, 2001, 25(5): 336-340.
    • (2001) Artificial Organs , vol.25 , Issue.5 , pp. 336-340
    • Burgreen, G.1    Antaki, J.F.2    Wu, Z.J.3
  • 8
    • 0034837086 scopus 로고    scopus 로고
    • Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics
    • Apel J, Paul R, Klaus S. Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics[J]. Artificial Organs, 2001, 25(5): 341-347.
    • (2001) Artificial Organs , vol.25 , Issue.5 , pp. 341-347
    • Apel, J.1    Paul, R.2    Klaus, S.3
  • 9
    • 0242301758 scopus 로고    scopus 로고
    • An estimation method of hemolysis within an axial flow blood pump by computational fluid dynamics analysis
    • Tetsuya Y, Kazumitsu S, Ayumi M. An estimation method of hemolysis within an axial flow blood pump by computational fluid dynamics analysis[J]. Artificial Organs, 2003, 27(10): 920-925.
    • (2003) Artificial Organs , vol.27 , Issue.10 , pp. 920-925
    • Tetsuya, Y.1    Kazumitsu, S.2    Ayumi, M.3
  • 10
    • 2342556423 scopus 로고    scopus 로고
    • Design and transient computational fluid dynamics study of a continuous axial flow ventricular assist device
    • Song Xinwei, Untaroiu A, Wood H G. Design and transient computational fluid dynamics study of a continuous axial flow ventricular assist device[J]. ASAIO Journal, 2004, 50(4): 215-224.
    • (2004) ASAIO Journal , vol.50 , Issue.4 , pp. 215-224
    • Song, X.1    Untaroiu, A.2    Wood, H.G.3
  • 11
    • 0018106974 scopus 로고
    • A rheological equation characterizing both the time dependent and steady state viscosity of human blood
    • Huang Ching-Rong, Fabisiak W. A rheological equation characterizing both the time dependent and steady state viscosity of human blood[J]. AIChE Symp Series, 1978, 74(1): 19-21.
    • (1978) AIChE Symp Series , vol.74 , Issue.1 , pp. 19-21
    • Huang, C.-R.1    Fabisiak, W.2
  • 13
    • 0025082325 scopus 로고
    • Estimation of shear stress-related blood damage in heart valve prostheses-in vitro comparision of 25 aortic valves
    • Giersiepen M, Wurzinger L J, Opitz R. Estimation of shear stress-related blood damage in heart valve prostheses-in vitro comparision of 25 aortic valves[J]. Int J Artif Organs, 1990, 13(5): 300-306.
    • (1990) Int J Artif Organs , vol.13 , Issue.5 , pp. 300-306
    • Giersiepen, M.1    Wurzinger, L.J.2    Opitz, R.3
  • 14
    • 0029085081 scopus 로고
    • Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump
    • Bludszuweit C. Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump[J]. Int J Artif Organs, 1995, 19(7): 590-596.
    • (1995) Int J Artif Organs , vol.19 , Issue.7 , pp. 590-596
    • Bludszuweit, C.1
  • 15
    • 2542439910 scopus 로고    scopus 로고
    • Numerical estimation of blood damage in artificial organs
    • Lenoid G, Klaus A. Numerical estimation of blood damage in artificial organs[J]. Artif Organs, 2004, 28(5): 499-507.
    • (2004) Artif Organs , vol.28 , Issue.5 , pp. 499-507
    • Lenoid, G.1    Klaus, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.