메뉴 건너뛰기




Volumn 27, Issue 11, 2006, Pages

Reference values for whole body and cerebral multi-frequency bio-impedance data in neonates less than 12 h postpartum

Author keywords

Cerebral; Multi frequency bio impedance; Neonate; Whole body

Indexed keywords

BIO-IMPEDANCE; CEREBRAL; ELECTRICAL IMPEDANCE; MULTI FREQUENCY; MULTI-FREQUENCY BIO-IMPEDANCE; MULTIPLE FREQUENCY; NEONATE; REFERENCE RANGE; REFERENCE VALUES; WHOLE-BODY;

EID: 33846073078     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/27/11/010     Document Type: Article
Times cited : (6)

References (23)
  • 1
    • 33748565282 scopus 로고
    • Dispersion and absorption in dielectrics
    • Cole K S and Cole R H 1941 Dispersion and absorption in dielectrics J. Chem. Phys. 9 341-51
    • (1941) J. Chem. Phys. , vol.9 , Issue.4 , pp. 341-351
    • Cole, K.S.1    Cole, R.H.2
  • 2
    • 0027410827 scopus 로고
    • Improved prediction of extracellular and total body water using impedance loci generated by multiple frequency bioelectrical impedance analysis
    • Cornish B H, Thomas B J and Ward L C 1993 Improved prediction of extracellular and total body water using impedance loci generated by multiple frequency bioelectrical impedance analysis Phys. Med. Biol. 38 337-46
    • (1993) Phys. Med. Biol. , vol.38 , Issue.3 , pp. 337-346
    • Cornish, B.H.1    Thomas, B.J.2    Ward, L.C.3
  • 3
    • 0029918355 scopus 로고    scopus 로고
    • Evaluation of multiple frequency bioelectrical impedance and Cole-Cole analysis for the assessment of body water volumes in healthy humans
    • Cornish B H, Ward L C, Thomas B J, Jebb S A and Elia M 1996 Evaluation of multiple frequency bioelectrical impedance and Cole-Cole analysis for the assessment of body water volumes in healthy humans Eur. J. Clin. Nutr. 50 159-64
    • (1996) Eur. J. Clin. Nutr. , vol.50 , pp. 159-164
    • Cornish, B.H.1    Ward, L.C.2    Thomas, B.J.3    Jebb, S.A.4    Elia, M.5
  • 4
    • 0024006938 scopus 로고
    • The prediction of total body water using bioelectrical impedance in children and adolescents
    • Davies P S, Preece M, Hicks C and Halliday D 1988 The prediction of total body water using bioelectrical impedance in children and adolescents Ann. Hum. Biol. 15 237-40
    • (1988) Ann. Hum. Biol. , vol.15 , Issue.3 , pp. 237-240
    • Davies, P.S.1    Preece, M.2    Hicks, C.3    Halliday, D.4
  • 5
    • 0019498114 scopus 로고
    • Transcephalic impedance in the neonate: An indicator of intracranial hemorrhage, asphyxia, and delayed maturation
    • Ellison P H and Evers J 1981 Transcephalic impedance in the neonate: an indicator of intracranial hemorrhage, asphyxia, and delayed maturation J. Pediatr. 98 968-71
    • (1981) J. Pediatr. , vol.98 , Issue.6 , pp. 968-971
    • Ellison, P.H.1    Evers, J.2
  • 6
    • 0029047991 scopus 로고
    • Bioelectric impedance detects fluid retention in patients undergoing cardiopulmonary bypass
    • Gonzalez J, Morrissey T, Byrne T, Rizzo R and Wilmore D 1995 Bioelectric impedance detects fluid retention in patients undergoing cardiopulmonary bypass J. Thorac. Cardiovasc. Surg. 110 111-8
    • (1995) J. Thorac. Cardiovasc. Surg. , vol.110 , Issue.1 , pp. 111-118
    • Gonzalez, J.1    Morrissey, T.2    Byrne, T.3    Rizzo, R.4    Wilmore, D.5
  • 7
    • 0014592694 scopus 로고
    • Correlation of whole-body impedance with total body water volume
    • Hoffer E C, Meador C K and Simpson D C 1969 Correlation of whole-body impedance with total body water volume J. Appl. Phys. 27 531-4
    • (1969) J. Appl. Phys. , vol.27 , pp. 531-534
    • Hoffer, E.C.1    Meador, C.K.2    Simpson, D.C.3
  • 8
    • 0029804711 scopus 로고    scopus 로고
    • Monitoring of extracellular and total body water during haemodialysis using multifrequency bio-electrical impedance analysis
    • Johnson D W, Thomas B J, Fleming S J, Westhuyzen J, Moran D and Ward L C 1996 Monitoring of extracellular and total body water during haemodialysis using multifrequency bio-electrical impedance analysis Kidney Blood Press Res. 19 94-9
    • (1996) Kidney Blood Press Res. , vol.19 , pp. 94-99
    • Johnson, D.W.1    Thomas, B.J.2    Fleming, S.J.3    Westhuyzen, J.4    Moran, D.5    Ward, L.C.6
  • 9
    • 0029783015 scopus 로고    scopus 로고
    • Use of bioelectrical impedance analysis measurements in the clinical management of patients undergoing dialysis
    • Kushner R F, de Vries P M and Gudivaka R 1996 Use of bioelectrical impedance analysis measurements in the clinical management of patients undergoing dialysis Am. J. Clin. Nutr. 64 503S-9S
    • (1996) Am. J. Clin. Nutr. , vol.64
    • Kushner, R.F.1    De Vries, P.M.2    Gudivaka, R.3
  • 10
    • 0032915032 scopus 로고    scopus 로고
    • Methods for measuring body composition in newborns-a comparative analysis
    • Lapillone A and Sallle B L 1999 Methods for measuring body composition in newborns-a comparative analysis J. Pediatr. Endocrinol. Metab. 12 125-37
    • (1999) J. Pediatr. Endocrinol. Metab. , vol.12 , pp. 125-137
    • Lapillone, A.1    Sallle, B.L.2
  • 11
    • 0034096871 scopus 로고    scopus 로고
    • Measurement of extracellular fluid volume in the neonate using multiple frequency bio-impedance analysis
    • Lingwood B E, Coghlan J P, Ward L C, Charles B G and Colditz P B 2000 Measurement of extracellular fluid volume in the neonate using multiple frequency bio-impedance analysis Physiol. Meas. 21 251-62
    • (2000) Physiol. Meas. , vol.21 , Issue.2 , pp. 251-262
    • Lingwood, B.E.1    Coghlan, J.P.2    Ward, L.C.3    Charles, B.G.4    Colditz, P.B.5
  • 12
    • 0037178670 scopus 로고    scopus 로고
    • The non-invasive measurement of cerebral bio-impedance for detection of cerebral edema in the neonatal piglet
    • Lingwood B E, Dunster K R, Colditz P B and Ward L C 2002 The non-invasive measurement of cerebral bio-impedance for detection of cerebral edema in the neonatal piglet Brain Res. 945 97-105
    • (2002) Brain Res. , vol.945 , Issue.1 , pp. 97-105
    • Lingwood, B.E.1    Dunster, K.R.2    Colditz, P.B.3    Ward, L.C.4
  • 13
    • 0037453267 scopus 로고    scopus 로고
    • Cerebral impedance and neurological outcome following a mild or severe hypoxic/ischemic episode in neonatal piglets
    • Lingwood B E, Dunster K R, Healy G N, Ward L C and Colditz P B 2003 Cerebral impedance and neurological outcome following a mild or severe hypoxic/ischemic episode in neonatal piglets Brain Res. 969 160-7
    • (2003) Brain Res. , vol.969 , Issue.1-2 , pp. 160-167
    • Lingwood, B.E.1    Dunster, K.R.2    Healy, G.N.3    Ward, L.C.4    Colditz, P.B.5
  • 14
    • 23044496354 scopus 로고    scopus 로고
    • Cardiorespiratory monitoring equipment interferes with whole body impedance measurements
    • Lingwood B E, Dunster K R and Ward L C 2005 Cardiorespiratory monitoring equipment interferes with whole body impedance measurements Physiol. Meas. 25 S235-40
    • (2005) Physiol. Meas. , vol.25
    • Lingwood, B.E.1    Dunster, K.R.2    Ward, L.C.3
  • 15
    • 0024263738 scopus 로고
    • Estimation of body fluid volumes using tetrapolar bioelectrical impedance measurements
    • Lukaski H C and Bolonchuk W W 1988 Estimation of body fluid volumes using tetrapolar bioelectrical impedance measurements Aviat. Space Environ. Med. 59 1163-9
    • (1988) Aviat. Space Environ. Med. , vol.59 , pp. 1163-1169
    • Lukaski, H.C.1    Bolonchuk, W.W.2
  • 16
    • 0029760377 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis in body composition measurement: National Institutes of Health Technology Assessment Conference Statement
    • National Institutes of Health 1996 Bioelectrical impedance analysis in body composition measurement: National Institutes of Health Technology Assessment Conference Statement Am. J. Clin. Nutr. 64 524S-32S
    • (1996) Am. J. Clin. Nutr. , vol.64
  • 20
    • 0031420481 scopus 로고    scopus 로고
    • Assessment of total body water using bioelectrical impedance analysis in neonates receiving intensive care
    • Tang W, Ridout D and Modi N 1997 Assessment of total body water using bioelectrical impedance analysis in neonates receiving intensive care Arch Dis. Child Fetal Neonat. Ed. 77 F123-6
    • (1997) Arch Dis. Child Fetal Neonat. Ed. , vol.77
    • Tang, W.1    Ridout, D.2    Modi, N.3
  • 21
    • 0026946320 scopus 로고
    • Bioelectrical impedance analysis for measurement of body fluid volumes: A review
    • Thomas B J, Cornish B H and Ward L C 1992 Bioelectrical impedance analysis for measurement of body fluid volumes: a review J. Clin. Eng. 17 505-10
    • (1992) J. Clin. Eng. , vol.17 , Issue.6 , pp. 505-510
    • Thomas, B.J.1    Cornish, B.H.2    Ward, L.C.3
  • 22
    • 33846074981 scopus 로고    scopus 로고
    • Bioelectric impedance techniques in medicine: Part II, Section V. Total body impedance and fluid compartments
    • Valentinuzzi M E, Morucci J-P and Felice C J 1996 Bioelectric impedance techniques in medicine: Part II, Section V. Total body impedance and fluid compartments Crit. Rev. Biomed. Eng. 24 389-414
    • (1996) Crit. Rev. Biomed. Eng. , vol.24 , pp. 389-414
    • Valentinuzzi, M.E.1    Morucci, J.-P.2    Felice, C.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.