-
2
-
-
0003892109
-
-
European Communities EUR 16262 EN Official Publications of the European Communities, Luxembourg
-
European Communities EUR 16262 EN (2000) European guidelines on quality criteria for computed tomography. Official Publications of the European Communities, Luxembourg
-
(2000)
European Guidelines on Quality Criteria for Computed Tomography
-
-
-
3
-
-
19544385579
-
Pregnancy and medical radiation
-
International Commission on Radiological Protection (ICRP) Pergamon, Oxford
-
International Commission on Radiological Protection (ICRP) (2000) Pregnancy and medical radiation. Annals of the ICRP publication 84. Pergamon, Oxford
-
(2000)
Annals of the ICRP Publication 84
-
-
-
4
-
-
33846074170
-
Guidance for protection of unborn children and infants irradiated due to parental medical exposures
-
European Commission, DG XI Official Publications of the European Communities, Luxembourg
-
European Commission, DG XI (1998) Guidance for protection of unborn children and infants irradiated due to parental medical exposures. Radiation Protection 100. Official Publications of the European Communities, Luxembourg (http://www.europa.eu.int/comm/energy/nuclear/ radioprotection/publication/doc/100_en.pdf)
-
(1998)
Radiation Protection 100
-
-
-
5
-
-
0033770744
-
Determining and reporting fetal radiation exposure from diagnostic radiation
-
Karam PA (2000) Determining and reporting fetal radiation exposure from diagnostic radiation. Health Phys 79(2):85-90
-
(2000)
Health Phys
, vol.79
, Issue.2
, pp. 85-90
-
-
Karam, P.A.1
-
6
-
-
0036852618
-
Normalized conceptus doses for abdominal radiographic examinations calculated using a Monte Carlo technique
-
Damilakis J, Tzedakis A, Sideri L, Perisinakis K (2002) Normalized conceptus doses for abdominal radiographic examinations calculated using a Monte Carlo technique. Med Phys 29:2641-2648
-
(2002)
Med Phys
, vol.29
, pp. 2641-2648
-
-
Damilakis, J.1
Tzedakis, A.2
Sideri, L.3
Perisinakis, K.4
-
7
-
-
0033858074
-
Estimation of fetal radiation dose from computed tomography scanning in late pregnancy
-
Damilakis J, Perisinakis K, Voloudaki A, Gourtsoyiannis N (2000) Estimation of fetal radiation dose from computed tomography scanning in late pregnancy. Invest Radiol 35(9):527-533
-
(2000)
Invest Radiol
, vol.35
, Issue.9
, pp. 527-533
-
-
Damilakis, J.1
Perisinakis, K.2
Voloudaki, A.3
Gourtsoyiannis, N.4
-
8
-
-
0037478631
-
Software for the estimation of foetal radiation dose to patients and staff in diagnostic radiology
-
Osei EK, Darko JB, Faulkner K, Kotre CJ (2003) Software for the estimation of foetal radiation dose to patients and staff in diagnostic radiology. Radiol Prot 23:183-194
-
(2003)
Radiol Prot
, vol.23
, pp. 183-194
-
-
Osei, E.K.1
Darko, J.B.2
Faulkner, K.3
Kotre, C.J.4
-
9
-
-
0030972983
-
Estimation of fetal and effective dose for CT examinations
-
Adams EJ, Brettle DS, Jones AP, Hounsell AR, Mott DJ (1997) Estimation of fetal and effective dose for CT examinations. Br J Radiol 70:272-278
-
(1997)
Br J Radiol
, vol.70
, pp. 272-278
-
-
Adams, E.J.1
Brettle, D.S.2
Jones, A.P.3
Hounsell, A.R.4
Mott, D.J.5
-
10
-
-
0003574361
-
-
CTB Publications, D-21073, Hamburg
-
Nagel HD (2002) Radiation exposure in computed tomography, fundamentals, influencing parameters, dose assessment, optimisation, scanner data, terminology. CTB Publications, D-21073, Hamburg
-
(2002)
Radiation Exposure in Computed Tomography, Fundamentals, Influencing Parameters, Dose Assessment, Optimisation, Scanner Data, Terminology
-
-
Nagel, H.D.1
-
11
-
-
0003954535
-
-
European Commission (EC) Radiation protection 109. Official Publications of the European Communities, Luxembourg
-
European Commission (EC) (1999) European guidelines on diagnostic reference levels (DRLs) for medical exposures. Radiation protection 109. Official Publications of the European Communities, Luxembourg
-
(1999)
European Guidelines on Diagnostic Reference Levels (DRLs) for Medical Exposures
-
-
-
13
-
-
33846102282
-
-
European IRPA Congress Florens paper 150, (Florence, Italy 8-11 oct 2002)
-
Pettersson H, Helmrot E, Sandborg M, Nilsson J, Olsson S, Persliden J, Cederlund T (2002) Prenatal radiation exposures at diagnostic procedures: Methods to identify exposed pregnant patients. European IRPA Congress Florens paper 150, (Florence, Italy 8-11 oct 2002)
-
(2002)
Prenatal Radiation Exposures at Diagnostic Procedures: Methods to Identify Exposed Pregnant Patients
-
-
Pettersson, H.1
Helmrot, E.2
Sandborg, M.3
Nilsson, J.4
Olsson, S.5
Persliden, J.6
Cederlund, T.7
-
15
-
-
0033007275
-
Embryo depth during the first trimester. Data required for embryo dosimetry
-
Perisinakis K, Damilakis J, Vagios E, Gourtsoyiannis N (1999) Embryo depth during the first trimester. Data required for embryo dosimetry. Invest Radiol 34(7):449-454
-
(1999)
Invest Radiol
, vol.34
, Issue.7
, pp. 449-454
-
-
Perisinakis, K.1
Damilakis, J.2
Vagios, E.3
Gourtsoyiannis, N.4
-
16
-
-
33846052053
-
-
Rados ODS-60 (WinODS) RTI Electronics Mölndal, Sweden
-
Rados ODS-60 (WinODS) (1996) User guide doc no 2092 3914 ver 1.0, RTI Electronics Mölndal, Sweden
-
(1996)
User Guide Doc No 2092 3914 Ver 1.0
-
-
-
17
-
-
0003686689
-
A topographically and anatomically unified phantom model for organ dose determination in radiation hygiene
-
STUK-A87
-
Servomaa A, Rannikko S, Nikitin V, Golikov V, Ermakov I, Masarskyi L, Saltukova L (1989) A topographically and anatomically unified phantom model for organ dose determination in radiation hygiene. STUK-A87
-
(1989)
-
-
Servomaa, A.1
Rannikko, S.2
Nikitin, V.3
Golikov, V.4
Ermakov, I.5
Masarskyi, L.6
Saltukova, L.7
-
18
-
-
0032439673
-
Organ dose calculation in medical x-ray examinations by the program PCXMC
-
Servomaa A, Tapiovaara M (1998) Organ dose calculation in medical x-ray examinations by the program PCXMC. Radiat Prot Dosim 80:213-219
-
(1998)
Radiat Prot Dosim
, vol.80
, pp. 213-219
-
-
Servomaa, A.1
Tapiovaara, M.2
-
19
-
-
0004042080
-
PCXMC, APC-based Monte Carlo program for calculating patient doses in medical x-ray examinations
-
STUK-A139
-
Tapiovaara M, Lakkisto M, Servomaa A (1997) PCXMC, APC-based Monte Carlo program for calculating patient doses in medical x-ray examinations. STUK-A139
-
(1997)
-
-
Tapiovaara, M.1
Lakkisto, M.2
Servomaa, A.3
-
20
-
-
33846105600
-
-
ATOM Norfolk, Virginia 23513, USA
-
ATOM (2002) Adult female phantom handling instructions, CIRS tissue simulation technology, 2428 Almeda Avenue, Suite 212, Norfolk, Virginia 23513, USA. (http://www.cirsinc.com_admin@cirsinc.com)
-
(2002)
Adult Female Phantom Handling Instructions, CIRS Tissue Simulation Technology, 2428 Almeda Avenue, Suite 212
-
-
-
21
-
-
0032604360
-
A PC program for estimating organ dose and effective dose values in computed tomography
-
Kalender WA, Schmidt B, Zankl M, Schmidt M (1999) A PC program for estimating organ dose and effective dose values in computed tomography. Eur Radiol 9:555-562
-
(1999)
Eur Radiol
, vol.9
, pp. 555-562
-
-
Kalender, W.A.1
Schmidt, B.2
Zankl, M.3
Schmidt, M.4
-
22
-
-
0038079808
-
Conceptus radiation dose and risk from chest screen-film radiography
-
Damilakis J, Perisinakis K, Prassopoulos P, Dimovasili E, Varveris H, Gourtsoyiannis N (2003) Conceptus radiation dose and risk from chest screen-film radiography. Eur Radiol 13:406-441
-
(2003)
Eur Radiol
, vol.13
, pp. 406-441
-
-
Damilakis, J.1
Perisinakis, K.2
Prassopoulos, P.3
Dimovasili, E.4
Varveris, H.5
Gourtsoyiannis, N.6
|