1
-
-
0029237837
-
Review of recent research on heat transfer with mixtures, Part 1: Condensation, Part 2: Boiling and evaporation
-
Wang S., and Chato J.C. Review of recent research on heat transfer with mixtures, Part 1: Condensation, Part 2: Boiling and evaporation. ASHRAE Trans 101 Part 1 (1995) 1376-1401
-
(1995)
ASHRAE Trans
, vol.101
, Issue.PART 1
, pp. 1376-1401
-
-
Wang, S.1
Chato, J.C.2
-
2
-
-
33846003418
-
-
Rajapaksha L, Colbourne D, Suen KO. Size matching consideration during replacement of the condensing unit. In: Proc of ninth int refrige air conditioning conf at Purdue, USA, 2002.
-
-
-
-
3
-
-
33846012447
-
-
Rajapaksha L. Performance evaluation of reversible heat pumps when using refrigerant mixtures, PhD thesis, University of London, 2003.
-
-
-
-
4
-
-
33846017574
-
-
Didion DA, Bivenns DB. The role of refrigerant mixtures as alternatives, In: Proceedings of the ASHRAE CFC technol conf, NIST, Maryland, 1989. p. 57-69.
-
-
-
-
5
-
-
0028727951
-
Composition shifts of zeotropic HFC refrigerants in service
-
Stuart C.F., Murphy T., and Wilkinson S. Composition shifts of zeotropic HFC refrigerants in service. ASHRAE Trans 100 Part 2 (1994) 538-546
-
(1994)
ASHRAE Trans
, vol.100
, Issue.PART 2
, pp. 538-546
-
-
Stuart, C.F.1
Murphy, T.2
Wilkinson, S.3
-
6
-
-
43949155081
-
Glide matching with binary and ternary zeotropic refrigerant mixtures, Part 1 An experimental study
-
Mulroy W.J., Domanski P.A., and Didion D.A. Glide matching with binary and ternary zeotropic refrigerant mixtures, Part 1 An experimental study. Int J Refrig 17 4 (1994) 220-225
-
(1994)
Int J Refrig
, vol.17
, Issue.4
, pp. 220-225
-
-
Mulroy, W.J.1
Domanski, P.A.2
Didion, D.A.3
-
7
-
-
33845979391
-
-
Marques M, Domanski PA. Potential coefficient of performance improvements due to glide matching with R407C, In: Proc of seventh int refrige conf, Purdue, 1998. p. 101-8.
-
-
-
-
8
-
-
33845975899
-
-
Haselden GG, Carter K. The case of wide-boiling refrigerant mixtures for air-conditioning, Advance proof. In: Proc inst of ref, UK, session 1998-99 (2).
-
-
-
-
9
-
-
0037211007
-
Influence of reversing methods on the performance of a reversible water-to-water heat pump
-
Rajapaksha L., and Suen K.O. Influence of reversing methods on the performance of a reversible water-to-water heat pump. Appl Thermal Eng 23 (2003) 49-64
-
(2003)
Appl Thermal Eng
, vol.23
, pp. 49-64
-
-
Rajapaksha, L.1
Suen, K.O.2
-
10
-
-
0025546655
-
-
Granryd E, Conklin JC. Thermal performance analysis for heat exchangers using non-azeotropic refrigerant mixtures, In: ASME symp on heat transfer in adv energy syst, Dallas, 1990;HTD- 151:25-32.
-
-
-
-
11
-
-
0345534622
-
Effect of mixture composition on the formation of pinch points in condensers and evaporators for zeotropic refrigerant mixtures
-
Venkatarathnam G.S., and Sirinivasa M. Effect of mixture composition on the formation of pinch points in condensers and evaporators for zeotropic refrigerant mixtures. Int J Refrige 22 (1999) 205-215
-
(1999)
Int J Refrige
, vol.22
, pp. 205-215
-
-
Venkatarathnam, G.S.1
Sirinivasa, M.2
-
12
-
-
0030182762
-
Occurrence of pinch points in condensers and evaporators for refrigerant zeotropic mixtures
-
Venkatarathnam G., Mokashi G., and Sirinivasa M. Occurrence of pinch points in condensers and evaporators for refrigerant zeotropic mixtures. Int J Refrige 19 6 (1996) 361-368
-
(1996)
Int J Refrige
, vol.19
, Issue.6
, pp. 361-368
-
-
Venkatarathnam, G.1
Mokashi, G.2
Sirinivasa, M.3
-
13
-
-
33845999838
-
Efficiency of non-azeotropic refrigeration cycles
-
Liu X. Efficiency of non-azeotropic refrigeration cycles. Int Refrige Conf at Purdue (1998) 109-114
-
(1998)
Int Refrige Conf at Purdue
, pp. 109-114
-
-
Liu, X.1
-
14
-
-
0032320635
-
-
Schaefer LA, Shelton SV. Heat exchanger mean temperature differences for refrigerant mixtures, In: Proc of the ASME adv energy syst div, ASE, 1998. p. 38.
-
-
-
-
15
-
-
0142241504
-
Theoretical and experimental investigations of advantageous refrigerant mixture applications
-
Kruse H., Kuver M., Quast U., Schroeder M., and Upmeier B. Theoretical and experimental investigations of advantageous refrigerant mixture applications. ASHRAE Trans 91 Part 2B (1985) 1383-1418
-
(1985)
ASHRAE Trans
, vol.91
, Issue.PART 2B
, pp. 1383-1418
-
-
Kruse, H.1
Kuver, M.2
Quast, U.3
Schroeder, M.4
Upmeier, B.5
-
16
-
-
0030719048
-
Concentration shift when using refrigerant mixtures
-
Kruse H., and Wieschollek F. Concentration shift when using refrigerant mixtures. ASHRAE Trans 103 Part 1 (1997) 747-755
-
(1997)
ASHRAE Trans
, vol.103
, Issue.PART 1
, pp. 747-755
-
-
Kruse, H.1
Wieschollek, F.2
-
17
-
-
0142184961
-
Influence of liquid receiver on the performance of reversible heat pumps using refrigerant mixtures
-
Rajapaksha L., and Suen K.O. Influence of liquid receiver on the performance of reversible heat pumps using refrigerant mixtures. Int J Refrige 27 01 (2004) 53-62
-
(2004)
Int J Refrige
, vol.27
, Issue.1
, pp. 53-62
-
-
Rajapaksha, L.1
Suen, K.O.2
-
18
-
-
0035546314
-
A method to estimate the circulated composition in refrigeration and heat pump systems using zeotropic refrigerant mixtures
-
Johansson A., and Lundqvist P. A method to estimate the circulated composition in refrigeration and heat pump systems using zeotropic refrigerant mixtures. Int J Refrig 24 8 (2001) 798-808
-
(2001)
Int J Refrig
, vol.24
, Issue.8
, pp. 798-808
-
-
Johansson, A.1
Lundqvist, P.2
-
19
-
-
0029346539
-
Calculating circulation concentration of zeotropic refrigerant mixtures
-
Chen J., and Kruse H. Calculating circulation concentration of zeotropic refrigerant mixtures. HVAC R Res 1 3 (1995) 219-231
-
(1995)
HVAC R Res
, vol.1
, Issue.3
, pp. 219-231
-
-
Chen, J.1
Kruse, H.2
-
20
-
-
33845982824
-
-
Radermacher R, Hwang Y. Vapour compression heat pumps with refrigerant mixtures, Department of Mechanical Engineering, University of Maryland, USA, 2000.
-
-
-
-
21
-
-
33845973646
-
-
Rothfleisch PI. A simplified method of composition shifting with a distillation column for a heat pump employing a zeotropic refrigerant mixture, NISTIR 5689, National Institute of Standards and Technology, USA, 1995.
-
-
-
-
22
-
-
0022715578
-
Generalized correlation for condensation of binary mixtures inside a horizontal tube
-
Tandon T.N., Varrma H.K., and Gupta C.P. Generalized correlation for condensation of binary mixtures inside a horizontal tube. Int J Refrig 9 (1986) 134-136
-
(1986)
Int J Refrig
, vol.9
, pp. 134-136
-
-
Tandon, T.N.1
Varrma, H.K.2
Gupta, C.P.3
-
23
-
-
0017503807
-
Nucleate boiling in binary mixtures
-
Shock R.A.W. Nucleate boiling in binary mixtures. Int J Heat Mass Transfer 20 (1977) 701-709
-
(1977)
Int J Heat Mass Transfer
, vol.20
, pp. 701-709
-
-
Shock, R.A.W.1
-
25
-
-
0030232811
-
Boiling of new refrigerants: a state-of-the-art review
-
Thome J.R. Boiling of new refrigerants: a state-of-the-art review. Int J Refrig 19 7 (1996) 435-457
-
(1996)
Int J Refrig
, vol.19
, Issue.7
, pp. 435-457
-
-
Thome, J.R.1
-
26
-
-
0022879650
-
-
Schlunder EU. Heat transfer studies-nucleate boiling of mixtures, In: 8th Int Heat Transfer Conf, San Francisco, 1986;4:2073-2079.
-
-
-
-
27
-
-
0024901321
-
Nucleate pool boiling performance of acetone-ethanol and methylene chloride ethanol binary mixtures
-
Alpay H.E., and Balkan F. Nucleate pool boiling performance of acetone-ethanol and methylene chloride ethanol binary mixtures. Int J Heat Mass Transfer 32 12 (1989) 2403-2408
-
(1989)
Int J Heat Mass Transfer
, vol.32
, Issue.12
, pp. 2403-2408
-
-
Alpay, H.E.1
Balkan, F.2
-
28
-
-
0024737608
-
A study of flow boiling heat transfer with refrigerant mixtures
-
Jung D.S., McLinden M., Radermacher R., and Didion D.A. A study of flow boiling heat transfer with refrigerant mixtures. Int J Heat Mass Transfer 32 9 (1989) 1751-1764
-
(1989)
Int J Heat Mass Transfer
, vol.32
, Issue.9
, pp. 1751-1764
-
-
Jung, D.S.1
McLinden, M.2
Radermacher, R.3
Didion, D.A.4
-
29
-
-
0025546655
-
-
Granryd E, Conklin JC. Thermal performance analysis for heat exchangers using non-azeotropic refrigerant mixtures, ASME symp on heat transfer in Adv Energy Syst, Dallas, 1990;HTD-151:25-32.
-
-
-
|